6.   POST-CLEANING (NEUTRALIZING, SHUTTING  

DOWN, STORAGE)

Neutralizing the Descaling Solution

1.

   

WARNING:

 Do not dump low pH solution into sink or drains! Solution must 

be neutralized first! Typical minimum allowable pH is 5.5 to be able to be 

dumped into normal drains. Check with local, state and federal laws regarding 

the dumping of used descaling solution.

2.

   Goodway’s ScaleBreak® may be neutralized with an acid neutralizing agent 

(e.g. sodium carbonate/soda ash).

3.

 Slide 

pH Controller Switch 

to 

“OFF”.

4.

 Leave 

Main Pump

 Switch On (up position).

5.

 Close 

Valve #3

 (Pump Output Valve) about ¾.

6.

  Remove lid from 

Venting Drum

. Be careful with the over-splash.

7.

  

SLOWLY

 add the neutralizing agent to the 

Venting Drum

. Monitor the pH  

level – it should rise.

8.

   Continue to add neutralizing agent until pH is at an acceptable level  

(nominally 6.0 – 8.0).

IMPORTANT:

 DO NOT ADD NEUTRALIZING AGENT TOO QUICKLY!!! Certain 

reactions will cause severe foaming and overflow the venting drum.

SHUTTING DOWN

Once the descaling solution is neutralized:

1.

  Close the valves on the hoses.

2.

   Disconnect the hoses from the vessel. Leave the hoses attached to the 

Descaling Unit.

3.

   Drain the descaling solution into an appropriate container or down a wastewater 

drain by opening 

Valves #1

#2

,

 and

 

#3

 and the valves on the hoses.

4.

  When done draining the unit, close all valves on the unit.

5.

  Remove lid and fill Venting Drum with at least 10 gallons (37.8 L) of clean water.

6.

  Place the 

Chemical Pickup

 Hose in a bucket of clean water (1/2 gallon min).

7.

 Open 

Valves #1, #2, and #3

 and the valves on the hoses.

8.

  Slide the 

pH Controller Switch

 to 

“ON”

.

9.

  When the Venting Drum is empty, turn the 

pH Controller Switch

 to 

“OFF”

.

10.

   The pump can be drained be removing the plug at the bottom of the pump 

head. Access is from under unit, on the left side (same side as the 

pH Sensor

)

11.

  Remove the plug (

DO NOT LOSE!!

).

12.

   When pump in drained,  

replace plug.

13.

   Close 

Valves #1, #2, and #3 

on  

the unit.

14.

  Disconnect the hoses.

15.

   Follow steps for storage of  

pH Sensor

.

Drain Plug

Содержание GDS-15-PH

Страница 1: ...GDS 15 PH Goodway Descaling System With Automatic Ph Control Operating and Maintenance Instructions Read before operating...

Страница 2: ...Descaling Solution 18 Shutting Down 18 pH Sensor Storage 19 General Maintenance and Storage 19 Quick Start Guide 20 Accessories Spare Parts 21 Troubleshooting 22 Specifications 22 23 Wiring Diagram GD...

Страница 3: ...t 5 Keep bystanders children and visitors away while operating this unit 6 Turn unit off and relieve pressure in the hoses when done 7 Do not use while tired or under the influence of drugs alcohol or...

Страница 4: ...ilure close all ball valves on the unit to prevent backflow and chemical overflow of the unit CAUTION If you are unsure about chemical compatability call Goodway at once Using a non compatable chemica...

Страница 5: ...ands after using WARNING do not dump low ph solution less than 5 0 into sink or drain disposal must be according to local state and federal laws Warranty Information Please check the included warranty...

Страница 6: ...with one 1 GDS 15 PH unit two 2 15 4 5 m hoses with shut off valves one 1 pH Sensor Storage Solution bottle and one 1 box of pH Calibration packets Venting Drum 15 foot 4 5 m Hose with Shut Off Valve...

Страница 7: ...R SWITCH controls the main recirculation pump This switch must be in the ON position up for normal recirculation operation Circuit Breaker The CIRCUIT BREAKER is a fast acting resettable 15 amp circui...

Страница 8: ...s pH CONTROLLER DS 03 The pH Controller is the brains of the GDS 15 PH It monitors the pH of the descaling solution and injects chemical whenever the pH rises above the setpoint The pH Controller can...

Страница 9: ...GDS 15 PH 0519 9 Valve 1 Drum Valve Valve 2 Pump Input Valve Valve 3 Pump Output Valve PLUMBING CONNECTIONS Venting Drum Connection Power Cord Chemical Pickup Hose Control Valves...

Страница 10: ...requirements for ScaleBreak injection into units logistics on hose connections on inlet and return points 6 ScaleBreak general injection process understanding and logistics 7 CO2 gas escape venting re...

Страница 11: ...king temperatures if heat is to be applied It may be necessary to remove selected system components if the cleaning process might damage them The entire cleaning procedure process must be developed in...

Страница 12: ...wdriver into the CAL opening on the pH Controller and turn until the reading is correct If you cannot calibrate the sensor it may be damaged Call Goodway for more information To Check the Calibration...

Страница 13: ...sure the unit is plugged in and the GFCI is reset 4 Press the SET button on the pH Controller 5 Insert a small screwdriver in the SET opening 6 Turn the screwdriver clockwise for a higher pH Setpoint...

Страница 14: ...he appropriate catch basin 4 PRIME THE CHEMICAL PUMP AND MAIN PUMP The Chemical Pump and Main Pump MUST be primed for proper operation If not properly primed the descaling solution will not circulate...

Страница 15: ...y connecting the chemical pickup hose to a water supply and having it force fluids into the pump IMPORTANT Valve 1 Venting Drum Valve must be OPEN for proper operation with a closed vessel type system...

Страница 16: ...rum and clean the unit using the Auto mode on the pH Controller a Make sure the Venting Drum is only full up to the elbow of the Overfill Sensor This will allow the maximum amount of ScaleBreak to be...

Страница 17: ...ions to vent any fumes from the descaling operation and to provide extra volume for the chemical injected into the system To prevent the overfilling of the Venting Drum if too much chemical is added t...

Страница 18: ...eactions will cause severe foaming and overflow the venting drum SHUTTING DOWN Once the descaling solution is neutralized 1 Close the valves on the hoses 2 Disconnect the hoses from the vessel Leave t...

Страница 19: ...ry to maximize performance and longevity Protect unit from freezing temperatures Do not store unit outdoors To protect the unit from damage the plumbing pumps and hoses should be drained before the un...

Страница 20: ...itch to AUTO 12 If red OVERFILL ALARM lamp is lit Venting Drum is full on GDS 15 PH chemical pump will be disabled Drain some solution into a suitable container to continue page 13 13 After one hour o...

Страница 21: ...nsor Storage Solution DS 04 3 pH Calibration Packets DS 04 CAP pH Sensor Tip Cap DS SENSOR CAP pH Sensor Cam and Groove Cap Scalebreak 5 ScaleBreak Descaling Solution 5 Gallon Bucket Scalebreak 30 Sca...

Страница 22: ...LL ALARM Thermal breaker tripped motor overheated Chemical pump fuse is blown pH Rises Above Setpoint During Cleaning Chemical supply is empty Chemical Pump is not working see above pH Sensor is damag...

Страница 23: ...f priming Temperature N A Noise Level N A Voltage Hz 110 120 Volts AC 60 Hz Amps 10 75 Amps 120 Volts Watts 1240 Watts Voltage Hz 220 240 Volts AC 50 60 Hz Amps 5 38 Amps 240 Volts Watts 1240 Watts Ho...

Страница 24: ...GDS 15 PH 0519 24 WIRING DIAGRAM GDS 15 PH 120 VOLT...

Страница 25: ...GDS 15 PH 0519 25 WIRING DIAGRAM GDS 15 PH 240 VOLT...

Страница 26: ...GDS 15 PH 0519 26 PLUMBING DIAGRAM 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17...

Страница 27: ...e 3 4 6220 3 1 Hose Barb 1 5 DS 26 6 lg Nipple 1 6 DS 34 Check Valve 1 7 DS 25 3 lg Nipple 1 8 DS 22 Tee 2 9 DS 27 12 lg Nipple 3 10 DS 29 FxF Elbow 4 11 DS 26 6 lg Nipple 3 12 DS 30 MxF Elbow 1 13 DS...

Страница 28: ...rp Stamford CT USA Effective date May 24 2019 Goodway is a Trademark of Crossford International Goodway reserves the right to improve products contact the factory for the latest configuration and uses...

Отзывы: