14.

   Keep operation area clear of all persons. Do not use unit with children in the 

immediate area.

15.

   Check condition of hoses and make sure connections and fittings are secure 

before operating unit.

16.

   Do not use unit with combustible fluids or where combustible fluids or fumes 

may be present.

17.

   The Goodway AQ-V-3M is designed for US standard 115 volt, 60 Hz AC. Volt. 

Always check the specifications on the equipment before connecting electrical 

power to equipment. 

GROUNDING INSTRUCTIONS

This appliance must be grounded. If it should malfunction or breakdown, 

grounding provides a path of least resistance for electric current to reduce the risk 

of electric shock. This appliance is equipped with a cord having an equipment-

grounding conductor and grounding plug. The plug must be inserted into an 

appropriate outlet that is properly installed and grounded in accordance with all 

local codes and ordinances.

 WARNING–

 

Improper connection of the equipment-grounding conductor can 

result in a risk of electric shock. Check with a qualified electrician or service person 

if you are in doubt as to whether the outlet is properly grounded. Do not modify the 

plug provided with the appliance – if it will not fit the outlet, have a proper outlet 

installed by a qualified electrician.

 WARNING

– To Reduce The Risk Of Electric Shock – Use indoors only.

 WARNING

– To Reduce The Risk Of Electric Shock – Do not expose to rain.  

Store indoors.

SETUP

Remove the outer box and inspect for damage. Report any damage immediately to 

your carrier and Goodway. Any attempt at repairing damages may void warranty.
Inspect all of the packing material for all parts before discarding packaging 

material.

Содержание AQ-V-3M

Страница 1: ...AQ V 3M High Volume HEPA Filtered Duct Cleaning Vacuum Operating and Maintenance Instructions Read before operating ...

Страница 2: ...d to serving you in the future As with all Goodway products you can be assured that the finest quality components and workmanship have gone into this machine Please take a few minutes to read the following Operating and Maintenance Instructions Please pay particular attention to the safety instructions and exercise caution when using this machine GOODWAY TECHNOLOGIES CORPORATION HVAC FACILITY MAIN...

Страница 3: ... filters inside a building 8 Never expose the unit to rain or excess moisture store unit indoors in a cool dry area If the machine does not operate properly or has been damaged or exposed to water return it to factory for service 9 Always wear a protective respiratory mask and eye protection especially when operating vacuum and changing or cleaning filters 10 Inspect all AC power plugs to be sure ...

Страница 4: ...rounding conductor and grounding plug The plug must be inserted into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances WARNING Improper connection of the equipment grounding conductor can result in a risk of electric shock Check with a qualified electrician or service person if you are in doubt as to whether the outlet is properly groun...

Страница 5: ...s will need to have started collecting dust MAINTENANCE AND STORAGE The Filter Bag The filter bag should be cleaned after every duct cleaning job To clean the filter bag remove it from the vacuum empty the large debris into a proper waste container and then blow out the remainder of the debris or wash the filter bag Make sure there is no one else in the area if blowing out the remaining dust The B...

Страница 6: ...t creating enough restriction Not enough airflow vacuum is blocked completely Additional extension cord is not properly rated Over 100 ft requires a 10 gauge extension cord Motor Overheated Thermal Overload Tripped Wait for the motor to cool down The thermal overload sensor will reset If the motor has cooled down and didn t automatically reset Remove the switch plate S02 square drive and press the...

Страница 7: ...V 3M 7 TO RESET THE THERMAL OVERLOAD FOLLOW THE INSTRUCTIONS BELOW 1 Remove the 6 square drive screws on the front panel 2 Press the red button located on the front side of the electrical box on the motor ...

Страница 8: ...AQ V 3M 8 SPARE PARTS Voltage 115V Amps 13 8A Lift 6 9 H2O Flow 3000 CFM Intake 8 TECHNICAL DATA Filter Bag Main Cartridge Filter Biostatic Wrap AQ V 3M PFB AQ V 3M HPF AQ V 3M ESF ...

Страница 9: ...AQ V 3M 9 NOTES ...

Страница 10: ... GOODWAY TECHNOLOGIES CORPORATION 420 West Avenue Stamford CT 06902 USA Tel 203 359 4708 Toll Free Tel 800 243 7932 Fax 203 359 9601 Toll Free Fax 800 359 9625 Email goodway goodway com Visit www goodway com P N MNL AQ V 3M Copyright 2019 Goodway Technologies Corp Stamford CT USA Effective date March 08 2019 Goodway is a Trademark of Crossford International Goodway reserves the right to improve pr...

Отзывы: