GOODRICH Stormscope Series II Скачать руководство пользователя страница 44

WX-950

Installation Manual

3-7

Rev. C

m.

Observe the display to ensure the proper positioning of the test strikes, based on range and
azimuth settings on the WX-PA. The strikes should be within 10 degrees of the selected azimuth
and should plot at 60 nmi (½ 120 nmi).

NOTE

THE WX

-

PA IS USED ONLY TO CHECK SYSTEM FUNCTIONS

IT IS NOT CONSIDERED A

CALIBRATION STANDARD

.

n.

After testing for all ranges and bearings indicated, press 2ND, then MENU/ENTER to return to
the Main Menu.

14. To check range and azimuth plotting accuracy set up the WX-PA to simulate a series of strikes at 30

degree increments at WX-PA ranges of 120, 55, and 15 nmi:

a.

Select Circular Pattern mode on the WX-PA Mode Menu and press MENU/ENTR.

b.

Select a top mount or a bottom mount antenna configuration on the WX-PA keyboard (“ A”  key),
as appropriate.

NOTE

The WX-950 display should be set at 100 nmi on the 360 degree weather screen
and in strike display mode.

c.

Use the F1 and F2 keys to select a 120 nmi range and press "MENU/ENTR" to start the test.
The system should plot discharge points at approximately 60 nmi.

d.

Observe the display to ensure the proper positioning of the test strikes. The strikes should be
within 10 degrees of the 30 degree azimuth increment and within 12 nautical miles (20%) of 60
nmi.

NOTE

THE WX

-

PA IS USED ONLY TO CHECK SYSTEM FUNCTIONS

IT IS NOT CONSIDERED A

CALIBRATION STANDARD

.

e.

When complete, set the WX-PA for 55 nmi, set the WX-950 display for 50 nmi and repeat the
test.

1)

The System should plot points just outside of the 25 nmi ring.

2)

The strikes should be within 10 degrees of the 30 degree azimuth increment and within 5
nmi of 27.5 nmi.

f.

Repeat, setting the WX-950 display for 25 nmi and the WX-PA for 15 nmi.

g.

Again, observe the display to ensure the proper positioning of the test strikes within 10 degrees
of azimuth and within 2 nmi of 7.5 nmi.

15. To test the synchro functions:

a.

Set the WX-950 range to 200 nmi, and use the WX-PA (at any desired range and bearing) to plot
continuous discharge points on the CRT.

NOTE

During continuous output mode, the strike counter should read between 560 and 600.

b.

With the compass system turned on, physically turn the aircraft 45°  to the right (or manually
slew the compass clockwise), and verify that the previously plotted discharge points move 45°
counterclockwise.

16. Test for electrical noise and interference by running the noise monitor and strike test as detailed in

paragraph 4.4.4. The noise monitor is accessed from the SERVICE MENU (refer to paragraph 4.4).

Содержание Stormscope Series II

Страница 1: ...tions and recommended flightline maintenance information for the WX 950 Stormscope This information is supplemented and kept current by Change Notices and Service Bulletins published by Goodrich Avion...

Страница 2: ...ut This chapter contains instructions for doing post installation and return to service checkout of the WX 950 using the Goodrich Avionics SystemsWX PA Portable Analyzer Kit Chapter 4 Maintenance This...

Страница 3: ...ther than diagrams and schematics are identified with a miniature pointing hand Shading is used to highlight the area of diagrams and schematics containing a change Total number of pages in this publi...

Страница 4: ...scribe it briefly and include the manual part number the paragraph figure table number and the page number Send your comments to Goodrich Avionics Systems Attn Technical Publications 5353 52nd Street...

Страница 5: ...N 2 1 2 2 UNPACKING AND INSPECTING 2 1 2 3 PRE INSTALLATION TEST PROCEDURE 2 1 2 3 1 Equipment Required 2 1 2 3 2 Test Procedure 2 2 2 4 ANTENNA LOCATION 2 3 2 4 1 Interference Sources 2 4 2 4 2 Skin...

Страница 6: ...3 PERIODIC MAINTENANCE 4 1 4 3 1 Display Processor 4 1 4 3 2 Antenna 4 1 4 4 SERVICE MENU 4 2 4 4 1 System Data 4 2 4 4 2 Fault Log 4 4 4 4 3 CRT Test Pattern 4 5 4 4 4 Noise Monitor 4 6 4 5 FAULT IS...

Страница 7: ...Cable 2 13 2 9 Heading Input Cable Preparation 2 14 2 10 Mating Connector 2 16 2 11 Heading Flag KCS55 Connection 2 29 2 12 Instrument Panel Cutout and Mounting Holes 2 20 2 13 Display Processor Insta...

Страница 8: ...817 10950 001 1 1 1 4 Hardware Package P N 817 10951 001 1 1 2 1 Heading Input Cable Vendors 2 13 2 2 Stepper Input Connections KI 525 Indicator 2 14 2 3 Synchro Connections to Mating Connectors 2 15...

Страница 9: ...ZEL ANTENNA SYSTEM P N BLACK GRAY WHITE BLACK 830 10950 001 X X 830 10950 002 X X 830 10950 003 X X 830 10950 004 X X Table 1 2 Antenna Cable Part Numbers PART NUMBER LENGTH ft RIGHT ANGLE BACKSHELL S...

Страница 10: ...t listens for electromagnetic signals with a receiving antenna The antenna detects intra cloud inter cloud or cloud to ground electrical discharges within a 200 nmi radius of the aircraft and sends th...

Страница 11: ...t s operating controls The Display processor can mount in a 3ATI panel cutout from the front or rear No mounting tray is required although a mooring plate may be purchased for increased stability in h...

Страница 12: ...ee figure 1 4 supplied with the installation kit see table 1 1 The antenna is sealed against environmental extremes and is non repairable To inhibit the build up of precipitation static the antenna is...

Страница 13: ...URE Display Processor 20 to 55 degrees Celsius 4 to 131 degrees Fahrenheit Antenna 55 to 70 degrees Celsius 67 to 158 degrees Fahrenheit ALTITUDE Display Processor 35 000 feet Maximum Antenna 55 000 f...

Страница 14: ...Inverter If 400Hz synchro drive is not available 1 7 INSTALLATION APPROVAL The installation of Stormscope systems if not installed under a type certificate or supplemental type certificate must be tre...

Страница 15: ...to ATTENTION WARRANTY ADMINISTRATOR Goodrich Avionics Systems 5353 52nd Street S E Grand Rapids MI 49512 U S A 2 Equipment must be installed by a Goodrich Avionics Systems authorized dealer or instal...

Страница 16: ...WX 950 Installation Manual 1 8 Rev C This page intentionally left blank...

Страница 17: ...o shipping containers or equipment Visually inspect each component for evidence of damage Compare the equipment received with that noted on the packing list Immediately report any missing items or evi...

Страница 18: ...connecting disconnecting cables ensure that all power is removed 1 Connect the equipment as shown in figure 2 2 Figure 2 2 Test Setup 2 Rotate the OFF BRT knob clockwise about 180 degrees After approx...

Страница 19: ...ystem is operating properly Immediately report any problems to our Customer Service Department at 1 800 453 0288 or 1 616 949 6600 2 4 ANTENNA LOCATION Because Stormscope weather mapping systems detec...

Страница 20: ...n current path between the battery and alternator and the battery and blower motors or other heavy current carrying equipment Aircraft skin currents may cause antenna interference ANTENNA BATTERY ALTE...

Страница 21: ...E LOCATION ALTERNATE LOCATION PREFERRED LOCATIONS 2 4 7 Site Selection Select an antenna location that satisfies the criteria outlined in the preceding paragraphs The ideal guidelines of course cannot...

Страница 22: ...ach the doubler plate to the inside of the fuselage as shown in figure 2 4 3 Mount the antenna to the aircraft as shown in figure 2 4 CAUTION 1 Do not paint the antenna It has been coated with a speci...

Страница 23: ...nstallation Manual 2 7 Rev C Figure 2 4 Antenna and Doubler Installation 4 Seal around the entire perimeter of the antenna NOTE The antenna should not be sealed until the sensor performance tests are...

Страница 24: ...low the instrument for air circulation Viewing Angle The viewing angle for the display is not a critical factor The most favorable mounting position would be near eye level and no more than arms lengt...

Страница 25: ...FIG JUMPER N C N C N C NOT SUPPLIED SEE NOTE 2 CIRCUIT BREAKER HEADING INPUT CABLE NOT SUPPLIED SEE PARAGRAPH 2 6 3 FOR CABLE SPECIFICATIONS HEADING INPUT CABLE NOT SUPPLIED SEE PARAGRAPH 2 6 3 FOR CA...

Страница 26: ...tallations will require the right angle backshell Cut cable to the desired length and prepare in accordance with the guidelines shown in figure 2 7 Figure 2 6 Antenna Cable Figure 2 7 Antenna Cable Pr...

Страница 27: ...able lengths greater than 15 feet require a second shielded twisted pair to reduce the voltage drop connected to pins 20 and 21 refer to figure 2 5 Affix a circuit breaker label P N 78 8060 5733 3 pro...

Страница 28: ...ecialists 414 421 5300 FAX 414 421 5301 A E Petsche 1 800 777 9280 817 461 9473 FAX 817 277 2887 EDMO Distributors 1 800 235 3300 509 535 8280 FAX 1 800 828 0623 FAX 509 535 8266 PIC Wire and Cable 1...

Страница 29: ...d 2 3 provide heading source interconnect information Refer to the applicable manufacturers publication for specific interconnect guidelines to be followed NOTE Every effort has been made to correctly...

Страница 30: ...01 P1 v P2 P P2 s P2 v P2 t P2 r P2 u Sperry C6E C6J N A N A 39 38 40 37 36 Sperry C6 C6A C6C N A N A 18 19 20 21 41 Sperry C 14d e GND a b Z X Y Connections to 722 755 2 7 4 Inhibit Line NOTE Normal...

Страница 31: ...observe specified color designations Tie points are identified on the cable termination PCB If necessary this PCB can be removed to simply making the solder connections After the wiring connections ha...

Страница 32: ...different configurations Jumper configuration can be verified with a resistance check between pins 9 CONFIG JUMPER and 11 12V Simply compare the resistance measured between pins 9 and 11 with that sho...

Страница 33: ...C C NC NC 6 16 NC NC C NC C 6 97 NC NC NC C NC 7 28 NC NC NC C C 7 63 NC C NC C NC 8 01 NC C NC C C 8 43 NC NC C C NC 8 90 NC NC C C C 10 7 C NC NC NC NC 11 5 C NC NC NC C 12 3 C C NC NC NC 13 4 C C N...

Страница 34: ...WX 950 Installation Manual 2 19 Rev C Figure 2 11 Heading Flag KCS55 Connection...

Страница 35: ...y processor using 6 32 rivet nuts to secure the unit to the instrument panel For increased stability in high vibration environments the display processor can be secured to the instrument panel with a...

Страница 36: ...esigned for easy blind mating Simply align the connector assembly with the guide pins at the rear of the display processor and slide it in place Lock by turning the thumbscrew in a clockwise direction...

Страница 37: ...WX 950 Installation Manual 2 22 Rev C This page intentionally left blank...

Страница 38: ...familiarity with the set up and operation of the WX PA Portable Analyzer Kit P N 78 8060 5791 1 3 2 CONTROLS All operating controls are located on the front of the indicator Figure 3 1 shows the loca...

Страница 39: ...ialization screen see figure 3 2 will be displayed During initialization the system runs a series of self tests to ensure that all functions are operating properly These tests are designed to check th...

Страница 40: ...ear see figure 3 4 To continue operation press any key Figure 3 4 Recoverable Error Message b If a fatal i e non recoverable error is detected the message Continued operation is not possible will appe...

Страница 41: ...rrow The weather view range should change to 100 nmi d Press softkey D i e up arrow The weather view range should return to 200 nmi 7 Access the Service Menu refer to paragraph 4 4 and verify the info...

Страница 42: ...e aircraft communication system antenna cables Contact customer service for advice and assistance 13 To verify antenna orientation and the integrity of the antenna wiring a antenna phase check must be...

Страница 43: ...ell and strike modes press the button labeled CELL or STRIKE Press the arrow keys to step through the operating ranges h Select the Continuous Out mode displayed on the WX PA menu and press MENU ENTR...

Страница 44: ...he strikes should be within 10 degrees of the 30 degree azimuth increment and within 12 nautical miles 20 of 60 nmi NOTE THE WX PA IS USED ONLY TO CHECK SYSTEM FUNCTIONS IT IS NOT CONSIDERED A CALIBRA...

Страница 45: ...as it is running at high RPM with all systems powered An offending interference source can be isolated by shutting down one system at a time then clearing the display and observing the noise monitor...

Страница 46: ...Processor 1 Check that cable is properly mated and secured 2 Check to ensure unit is properly placed and secured to the instrument panel CAUTION Do not use cleaning solvents on the viewing face 3 Chec...

Страница 47: ...rvice Menu The buttons perform the following operations in this mode EXIT causes the system to exit the Service Menu and run the power on self test SELECT selects the highlighted item steps to the pre...

Страница 48: ...oot Software Version DSP Boot SW Ver NOTE The software version identified on the bottom of the processor represents the system software configuration i e a collective designator for all software firmw...

Страница 49: ...3 4 4 2 Fault Log The 20 most recent errors detected by the system self test are saved in the Fault Log For each error the corresponding error code and run time of occurrence are saved The fault log...

Страница 50: ...o display the fault data will be partially blank If the fault log is empty the following message is displayed NO FAULTS DETECTED If due to a failure of non volatile memory the fault log cannot be disp...

Страница 51: ...t is checked to see if electrical noise that will interfere with normal system operation is present No compression is Figure 4 7 Noise Monitor applied to the strikes Also displayed is a circle solid r...

Страница 52: ...olid ring on the display A small number of triggers and or random noise points inside the displayed ring is acceptable FAIL Significant activity triggers and or strike clusters or persistent indicatio...

Страница 53: ...mapping Trouble shooting electrical noise is discussed in paragraph 4 5 NOTE The system must pass both the Noise Monitor and Test Strike criteria to ensure proper operation 4 5 FAULT ISOLATION Most pr...

Страница 54: ...0 Processor Fault DSP processor memory Continued operation is not possible Contact Customer Service ERROR 11 Processor Fault DSP processor memory Continued operation is not possible Contact Customer S...

Страница 55: ...a location b If jumper does not agree with user selection Configuration Fault and Continued operation is not possible are displayed c Check jumper selection in mating connector assembly refer to parag...

Страница 56: ...ead of synchro or stepper Stepper XYZ Selected Heading Stabilization is not available a Press any key to continue b Check jumper selections in mating connector assembly refer to paragraph 2 8 table 2...

Страница 57: ...schedule a flight test for further troubleshooting 2 To check for interference radiated into the antenna or cable a Use a WX SM Skinmapper The Skinmapper checks for radiated noise only b To isolate no...

Страница 58: ...lacing the Fuse 3 While holding the bezel with one hand carefully pull the housing away from the rear of the chassis 4 Locate fuse F1 Unsolder and remove the fuse Use a de soldering tool to remove exc...

Страница 59: ...when packaging electronic assemblies Since the assembly must be packed tightly crystals in bag form cannot be used The use of loose crystals may cause unnecessary damage resulting in a cleaning proble...

Страница 60: ...cables are shipped from the factory with the antenna connector pre wired to one end SENSE Signal provided by the sense channel within the antenna Bipolar signal voltage 11 V Peak Max 05 to 1 V Peak 2...

Страница 61: ...Y LOOP Signal provided by the Y Loop winding within the antenna Bipolar signal voltage 11 V Peak Max 1 V Peak 200nmi WX PA Simulation Standard 20 20 Ohm output impedance single ended Loop current to G...

Страница 62: ...E Stepper heading input is selected via the STEP jumper located in the connector back shell Stepper Drive Motor 1 3 FREQUENCY Min 0 Hz Max Turn Rate Dependent 25 degree increments per edge transition...

Страница 63: ...eft softkey When activated in weather mode the strike buffers are cleared and all displayed lightning strikes are erased This input is diode isolated and debounced This input will perform any function...

Страница 64: ...14 V aircraft systems and a 3 A circuit breaker for 28 V systems CONNECTION J1 8 J1 21 A C POWER 14 28 VOLTS J1 7 J1 20 A C GROUND CABLE Use twisted shielded pair cable minimum 20 AWG VOLTAGE 11 32 V...

Страница 65: ...WX 950 Installation Manual A 6 Rev C This page intentionally left blank...

Отзывы: