Instructions for use
antistatic protective garment against heat risks, electric arc and liquid chemicals
Good
PRO
SF1
Oliver
PPE - category III
Tests:
Maintenance:
Before washing zip up the garment, fasten all Velcro fasteners and take off the suspenders. We recommend washing at 40°C with
gentle
machine wash, light spin, pH max.9. Use ordinary liquid detergents without any bleaching agents. Prewash excessively soiled garments.
Rinse thoroughly and tumble dry at max spin speed 800 rpm. We recommend free drying in a warm room or drying in a dryer in 2 cycles
(max 2x20min) at a lower temperature -
max 60°C. Re
-impregnate aftrer 20 washing cycles according to the instructions. Do not iron directly
onto reflective tapes. HIGHER WASHING AND DRYING TEMPERATURES CAUSE FASTER WEAR OUT OF THE GARMENT!
Storage:
Store in dry and well-ventilated areas away from direct sunlight and UV rays. Protect from any damage.
Notes:
Keep the garment clean otherwise it can lead to the degradation of its properties. Check after every use.
To ensure the greatest possible protection do not make any alternations to the garment and/or its design. The garment keeps its protective
features only in the environment with standard volume of oxygen. To maintain the required level of protection, every two-part suits must
be worn complete. To achieve maximum protective performance, it is necessary to wear the vest together with the flame retardant
garment which fully covers arms. Check and maintain the garment regularly, including FC treatment.
Manufacturer does not warrant nor
shall manufacturer be liable, or in any way responsible, for damages to a product caused by abuse (including, but not limited to, improper
use, lack of reasonable care and maintenance and/or any alteration). In case of any questions, please contact the manufacturer.
You will find a Declaration of Conformity at www.goodpro.cz
Notified Body 1023 performed EU Type-Examination of the suit
SF1 Oliver.
EN ISO 11612:2015
A1 B1 C1 F1
EN 1149-5:2018
IEC 61482-2:2018
ATPV = 11 cal/cm
2
APC 1
EN 13034+A1:2009
EN ISO 11611:2016
class 1 / A1
Test according EN ISO 11612:2015
Requirements
Evaluation
Heat resistance -
180 °C
ISO 17493
met
Limited flame spread
EN ISO 15025 , method A
A1
Convection heat
HTI
24
4
–
10 s
B1
Radiant heat
RHTI
24
7
–
20 s
C1
Contact heat
–
heat resistance 250 °C
5
–
10 s
F1
Test according EN 1149-5:2018
Requirements
Evaluation
Method 2
–
Half decay time
T
50
< 4 , S > 0,2
met
Test according IEC 61482-1-1:2019
Requirements
Evaluation
Electric arc
–
value ATPV
Min. 4 cal/cm
2
11 cal/cm
2
Test according EN 61482-1-2:2014
Requirements
Evaluation
short-circuit current
4 kA
APC 1
Test according EN 13034+A1:2009
Requirements
Evaluation
Resistence against repellency
H
2
SO
4
30%
NaOH 10%
R > 90 %
R > 95 %
class 2
class 3
Resistance against penetration
H
2
SO
4
30%
NaOH 10%
P < 5 %
P < 1 %
class 2
class 3
Test according EN ISO 11611:2016
Requirements
Evaluation
Limited flame spread
EN ISO 15025 , method A
A1
Small hot metal drops
15 drops / 40 K
met
Radiant heat
RHTI
24
> 7 s
met
Vertical resistance
> 10
5
Ω
met