background image

Instructions for use

 

                                                              

 

 

antistatic protective garment against heat risks, electric arc and liquid chemicals 

 

Good

PRO

 

SF1

 

Oliver 

 

PPE -  category III 

 

Tests: 

 
Maintenance: 
 
 

Before washing zip up the garment, fasten all Velcro fasteners and take off the suspenders. We recommend washing at 40°C with

  gentle 

machine  wash,  light  spin,  pH  max.9.  Use  ordinary  liquid  detergents  without  any  bleaching  agents.  Prewash  excessively  soiled  garments. 
Rinse thoroughly and tumble dry at max spin speed  800 rpm. We recommend free drying in a warm room or drying in a dryer in 2 cycles 
(max 2x20min) at a lower temperature -

max 60°C. Re

-impregnate aftrer 20 washing cycles according to the instructions. Do not iron directly 

onto reflective tapes. HIGHER WASHING AND DRYING TEMPERATURES CAUSE FASTER WEAR OUT OF THE GARMENT! 
 

Storage: 

Store in dry and well-ventilated areas away from direct sunlight and UV rays. Protect from any damage. 
 

Notes: 

Keep the garment clean otherwise it can lead to the degradation of its properties. Check after every use. 
To ensure the greatest possible protection do not make any alternations to the garment and/or its design. The garment keeps its protective 
features only in the environment with standard volume of oxygen. To maintain the required level of protection, every two-part suits must 
be  worn  complete.  To  achieve  maximum  protective  performance,  it  is  necessary  to  wear  the  vest  together  with  the  flame  retardant 
garment which fully covers  arms.  Check  and maintain the garment regularly, including FC treatment. 

Manufacturer does  not warrant nor 

shall manufacturer be liable, or in any way responsible, for damages to a product caused by abuse (including, but not limited to, improper 
use, lack of reasonable care and maintenance and/or any alteration). In case of any questions, please contact the manufacturer. 

 

You will find a Declaration of Conformity at www.goodpro.cz 

 

Notified Body 1023 performed EU Type-Examination of the suit 

SF1 Oliver.

 

 
 

 

             

EN ISO 11612:2015 

A1 B1 C1 F1 

 
 

              

 

EN 1149-5:2018 

 

 
 

 

 

IEC 61482-2:2018 

ATPV = 11 cal/cm

APC 1 

 
 
 

             

EN 13034+A1:2009 

 

 
 
 

        

EN ISO 11611:2016 

class 1 / A1

 

Test according EN ISO 11612:2015 

Requirements 

Evaluation 

Heat resistance - 

180 °C

 

ISO 17493 

met 

Limited flame spread 

EN ISO 15025 , method A 

A1 

Convection heat 

HTI

24

  4 

 10 s 

B1 

Radiant heat 

RHTI

24  

 20 s 

C1 

Contact heat 

 

heat resistance 250 °C

 

 10 s 

F1 

Test according EN 1149-5:2018 

Requirements 

Evaluation 

Method 2 

 Half decay time 

T

50

 < 4 , S > 0,2 

met 

Test according IEC 61482-1-1:2019 

Requirements 

Evaluation 

Electric arc 

 value ATPV 

Min. 4 cal/cm

2

 

11 cal/cm

2

 

Test according EN 61482-1-2:2014 

Requirements 

Evaluation 

short-circuit current 

4 kA 

APC 1 

Test according EN 13034+A1:2009 

Requirements 

Evaluation 

Resistence against repellency 

H

2

SO

4

  30% 

NaOH  10% 

R > 90 % 
R > 95 %

 

class 2 
class 3

 

Resistance against penetration 

H

2

SO

4

  30% 

NaOH  10% 

P < 5 % 
P < 1 %

 

class 2 
class 3

 

Test according EN ISO 11611:2016

 

Requirements

 

Evaluation 

Limited flame spread 

EN ISO 15025 , method A 

A1 

Small hot metal drops 

15 drops / 40 K 

met 

Radiant heat 

RHTI

24  

> 7 s 

met 

Vertical resistance

 

> 10

5

  

Ω

 

met

 