NOTE FOR THE REPLACING OF MEMORY IC
If a service repair is undertaken where it has been required to change the MEMORY IC, the following steps should be taken to
ensure correct data settings while making reference to TABLE 1.
NOTE:
ADDRESS
DATA
00
10
01
1E
02
04
03
6A
04
00
05
00
06
00
07
2F
08
40
09
60
ADDRESS
DATA
0C
0D
0E
0F
10
11
12
13
14
15
ADDRESS
DATA
18
A3
19
89
1A
35
1B
5F
1C
05
1D
F0
1E
35
1F
F2
20
00
21
00
ADDRESS
DATA
24
00
25
5F
26
01
27
F1
28
01
29
F0
2A
0E
2B
00
2C
01
2D
01
0A
02
0B
08
16
17
22
00
23
00
2E
06
2F
01
ADDRESS
30
04
31
00
32
00
33
18
34
00
35
00
36
00
37
00
38
00
39
00
3A
00
3B
00
3D
2B
3E
3F
DATA
ADDRESS
DATA
3C
6C
00
B3
35
66
FA
40
80
6A
00
40
35
00
Table 1
21
15
Initial Data setting will not be possible if clock has been set. To reset clock, either unplug AC cord and allow
at least 30 minutes before Power On or alternatively, discharge backup capacitor. No need the setting for after INI 3F.
3.
4.
5.
6.
7.
8.
The unit will now have the correct DATA for the new MEMORY IC.
1.
2.
Fig. 1
ADDRESS is now selected and should "blink". Using the SET + or - keys on the remote, step through the
ADDRESS until required ADDRESS to be changed is reached.
Press ENTER to select DATA. When DATA is selected, it will "blink".
Again, step through the DATA using SET + or - until required DATA value has been selected.
Pressing ENTER will take you back to ADDRESS for further selection if necessary.
Repeat steps 3 to 6 until all data has been checked.
When satisfied correct DATA has been entered, turn POWER off (return to STANDBY MODE) to finish DATA input.
Enter DATA SET mode by setting VOLUME to minimum.
While holding down VOLUME button on front cabinet, press key 6 on remote control simultaneously.
ADDRESS and DATA should appear as FIG 1.
INIT 00 83
0010
0003
POWER ON
PLAY/REC
ADDRESS
DATA
C4-1