E
SPECIFICACIONES
DEL
P
RODUCTO
SS-
PGBC50-S
www.goodmanmfg.com
11
Aire de
Interior
Temperatura del Aire del Condensador
75°F
85°F
95°F
105°F
115°F
SCFM WB
Total
KBTU/h
Sens
KBTU/h
kW
Total
KBTU/h
Sens
KBTU/h
kW
Total
KBTU/h
Sens
KBTU/h
kW
Total
KBTU/h
Sens
KBTU/h
kW
Total
KBTU/h
Sens
KBTU/h
kW
3400
72
149.0
71.7
9.95
140.0
66.6
11.27
131.1
61.5
12.59
122.1
56.4
13.91
113.1
51.3
15.23
67
137.5
86.8
9.31
128.6
82.2
10.59
119.8
77.6
11.86
111.0
73.0
13.14
102.1
68.4
14.41
62
125.1
106.6
8.89
119.0
99.7
10.07
113.0
92.8
11.25
106.9
85.9
12.43
100.9
79.0
13.61
57
120.9
115.5
8.54
114.1
106.4
9.78
107.3
97.2
11.01
100.5
88.1
12.24
93.7
79.0
13.47
4000
72
155.4
79.5
10.28
145.7
74.1
11.62
136.1
68.7
12.96
126.4
63.3
14.30
116.7
57.9
15.64
67
142.6
101.8
9.62
133.7
95.5
10.92
124.8
89.2
12.22
115.9
82.9
13.52
107.0
76.6
14.82
62
130.1
124.2
8.95
123.1
114.7
10.29
116.1
105.3
11.62
109.1
95.8
12.95
102.1
86.3
14.29
57
130.1
124.2
8.95
123.1
114.7
10.29
116.1
105.3
11.62
109.1
95.8
12.95
102.1
86.3
14.29
4600
72
159.2
85.4
10.50
149.5
80.1
11.85
139.8
74.9
13.20
130.0
69.6
14.55
120.3
64.3
15.90
67
146.4
114.4
9.86
137.5
107.2
11.17
128.5
100.0
12.48
119.6
92.7
13.78
110.6
85.5
15.09
62
137.5
131.9
9.39
129.9
121.7
10.75
122.2
111.6
12.11
114.6
101.4
13.46
107.0
91.3
14.82
57
137.5
131.9
9.39
129.9
121.7
10.75
122.2
111.6
12.11
114.6
101.4
13.46
107.0
91.3
14.82
Las capacidades de calefacción sensible indicadas se basan en aire entrante a 80ºF con bulbo seco en el serpentín evaporador. Para otras capacidades de calefac-
ción sensible, restar 84 BTU/H cada 100 CFM de aire en el serpentín evaporador por cada grado por debajo de 80ºF ó sumar 84 BTU/h cada 100 CFM de aire en el
evaporador por encima de 80ºF.
D
ATOS
DE
C
APACIDAD
DE
E
NFRIAMIENTO
(
CONT
.)
T
ABLA
2B: PGB120245-5 (U
NIDADES
I
NGLESAS
)
Aire de
Interior
Temperatura del Aire del Condensador
75°F
85°F
95°F
105°F
115°F
SCFM
WB
Total
KBTU/h
Sens
KBTU/h
kW
Total
KBTU/h
Sens
KBTU/h
kW
Total
KBTU/h
Sens
KBTU/h
kW
Total
KBTU/h
Sens
KBTU/h
kW
Total
KBTU/h
Sens
KBTU/h
kW
4760
72
219.0
100.8
16.42
205.3
95.6
18.63
191.7
90.4
20.83
178.0
85.1
23.04
164.4
79.9
25.25
67
202.0
121.4
15.36
188.6
117.7
17.50
175.2
113.9
19.63
161.8
110.2
21.76
148.4
106.5
23.89
62
183.8
149.6
14.67
174.5
142.9
16.64
165.2
136.3
18.61
155.9
129.6
20.59
146.6
123.0
22.56
57
177.6
162.6
14.10
167.2
152.7
16.15
156.9
142.8
18.21
146.5
132.9
20.27
136.1
123.0
22.33
5600
72
228.3
111.6
16.97
213.6
106.3
19.21
199.0
100.9
21.45
184.3
95.5
23.68
169.6
90.1
25.92
67
209.5
142.7
15.87
196.0
136.9
18.05
182.5
131.0
20.22
169.0
125.2
22.40
155.5
119.3
24.46
62
191.1
174.8
14.77
180.5
164.7
17.00
169.8
154.6
19.23
159.1
144.5
21.46
148.4
134.4
23.68
57
191.1
174.8
14.77
180.5
164.7
17.00
169.8
154.6
19.23
159.1
144.5
21.46
148.4
134.4
23.68
6440
72
233.9
119.7
17.33
219.1
114.8
19.59
204.4
109.9
21.85
189.6
105.0
24.11
174.9
100.1
26.37
67
215.1
160.4
16.27
201.5
153.6
18.46
187.9
146.8
20.64
174.3
140.0
22.83
160.7
133.2
25.01
62
202.0
185.6
15.49
190.4
174.7
17.76
178.8
163.9
20.03
167.1
153.0
22.30
155.5
142.1
24.57
57
202.0
185.6
15.49
190.4
174.7
17.76
178.8
163.9
20.03
167.1
153.0
22.30
155.5
142.1
24.57
Las capacidades de calefacción sensible indicadas se basan en aire entrante a 80ºF con bulbo seco en el serpentín evaporador. Para otras capacidades de calefac-
ción sensible, restar 84 BTU/H cada 100 CFM de aire en el serpentín evaporador por cada grado por debajo de 80ºF ó sumar 84 BTU/h cada 100 CFM de aire en el
evaporador por encima de 80ºF.
T
ABLA
3B: PGB180245-5 (U
NIDADES
I
NGLESAS
)
Aire de
Interior
Temperatura del Aire del Condensador
23.9°C
29.4°C
35.0°C
40.6°C
46.1°C
L/S
WB
Cap.
Total
Cap.
Sens
kW
Cap.
Total
Cap.
Sens
kW
Cap.
Total
Cap.
Sens
kW
Cap.
Total
Cap.
Sens
kW
Cap.
Total
Cap.
Sens
kW
2246
22.2
64.17
29.53
16.42
60.17
28.00
18.63
56.17
26.48
20.83
52.17
24.95
23.04
48.17
23.43
25.25
19.4
59.19
35.59
15.36
55.27
34.49
17.50
51.35
33.39
19.63
47.42
32.29
21.76
43.50
31.20
23.89
16.7
53.86
43.83
14.67
51.14
41.88
16.64
48.42
39.93
18.61
45.69
37.99
20.59
42.97
36.04
22.56
13.9
52.05
47.66
14.10
49.01
44.75
16.15
45.97
41.85
18.21
42.93
38.94
20.27
39.90
36.04
22.33
2643
22.2
66.90
32.71
16.97
62.61
31.14
19.21
58.31
29.56
21.45
54.01
27.99
23.68
49.71
26.42
25.92
19.4
61.40
41.82
15.87
57.44
40.10
18.05
53.48
38.39
20.22
49.53
36.68
22.40
45.57
34.96
24.57
16.7
56.02
51.22
14.77
52.89
48.26
17.00
49.76
45.30
19.23
46.63
42.34
21.46
43.50
39.38
23.68
13.9
56.02
51.22
14.77
52.89
48.26
17.00
49.76
45.30
19.23
46.63
42.34
21.46
43.50
39.38
23.68
3039
22.2
68.54
35.09
17.33
64.22
33.66
19.59
59.89
32.22
21.85
55.57
30.78
24.11
51.24
29.34
26.37
19.4
63.03
47.01
16.27
59.05
45.02
18.46
55.07
43.02
20.64
51.09
41.02
22.83
47.11
39.03
25.01
16.7
59.20
54.38
15.49
55.79
51.20
17.76
52.38
48.02
20.03
48.98
44.84
22.30
45.57
41.66
24.57
13.9
59.20
54.38
15.49
55.79
51.20
17.76
52.38
48.02
20.03
48.98
44.84
22.30
45.57
41.66
24.57
Las capacidades de calefacción sensible indicadas se basan en aire entrante a 26,7ºC con bulbo seco en el serpentín evaporador. Para otras capacidades de calefac-
ción sensible, restar 44,32 W cada 47 L/S de aire en el serpentín evaporador por cada grado por debajo de los 26,7ºC o sumar 44,32 W cada 47 L/S de aire en el
evaporador por encima de la temperatura mencionada.
T
ABLA
3A: PGB180245-5 (U
NIDADES
SI)