background image

SS-PCB50

P

RODUCT

 S

PECIFICATIONS

INDOOR

AIR

CONDENSER AIR TEMPERATURE

75°F

85°F

95°F

105°F

115°F

SCFM

WB

Total

Kbtuh

Sens

Kbtuh

Kw

Total

Kbtuh

Sens

Kbtuh

Kw

Total

Kbtuh

Sens

Kbtuh

Kw

Total

Kbtuh

Sens

Kbtuh

Kw

Total

Kbtuh

Sens

Kbtuh

Kw

2550

72

111.8

52.8

8.36

104.6

49.6

9.29

97.5

46.3

10.23

90.3

43.0

11.17

83.1

39.7

12.10

67

103.2

63.8

7.82

96.1

61.1

8.73

89.1

58.4

9.64

82.1

55.6

10.55

75.0

52.9

11.46

62

93.9

78.5

7.46

89.0

74.1

8.30

84.0

69.8

9.14

79.1

65.5

9.98

74.1

61.1

10.82

57

90.7

85.2

7.18

85.2

79.1

8.06

79.8

73.1

8.94

74.3

67.1

9.83

68.8

61.1

10.71

3000

72

116.6

58.5

8.63

108.9

55.1

9.58

101.2

51.7

10.53

93.5

48.2

11.48

85.7

44.8

12.43

67

107.0

74.9

8.08

99.9

71.0

9.01

92.8

67.1

9.93

85.7

63.2

10.86

78.6

59.3

11.78

62

97.6

91.6

7.53

92.0

85.4

8.49

86.3

79.2

9.44

80.7

73.0

10.40

75.0

66.8

11.35

57

97.6

91.6

7.53

92.0

85.4

8.49

86.3

79.2

9.44

80.7

73.0

10.40

75.0

66.8

11.35

3450

72

119.5

62.9

8.82

111.7

59.6

9.77

103.9

56.3

10.73

96.2

53.0

11.69

88.4

49.8

12.64

67

109.9

84.2

8.28

102.7

79.7

9.21

95.6

75.2

10.14

88.4

70.7

11.07

81.3

66.2

11.99

62

103.2

97.2

7.89

97.0

90.6

8.86

90.9

83.9

9.84

84.7

77.3

10.81

78.6

70.7

11.78

57

103.2

97.2

7.89

97.0

90.6

8.86

90.9

83.9

9.84

84.7

77.3

10.81

78.6

70.7

11.78

F

AN

 P

ERFORMANCE

 D

ATA

 (

CONT

.)

C

OMPONENT

 P

RESSURE

 D

ROPS

MODEL

CFM

WET COIL

ELEC. HEAT

MED. EFF. FILTERS

ECONO. RETURN AIR DAMP-

ER

090

2600

0.06

0.03

0.03

0.14

3000

0.06

0.04

0.04

0.14

3400

0.07

0.05

0.05

0.18

120

3600

0.05

0.05

0.03

0.14

4000

0.05

0.06

0.04

0.14

4400

0.05

0.08

0.04

0.14

180

5000

0.13

0.10

0.06

0.18

5400

0.13

0.12

0.06

0.21

5600

0.16

0.13

0.08

0.23

C

OOLING

 C

APACITY

 D

ATA

PCB090-5 (SI U

NITS

)

INDOOR

AIR

CONDENSER AIR TEMPERATURE

23.9°C

29.4°C

35.0°C

40.6°C

46.1°C

L/S

WB

Total

Cap.

Sens
Cap.

Kw

Total

Cap.

Sens
Cap.

Kw

Total

Cap.

Sens
Cap.

Kw

Total

Cap.

Sens
Cap.

Kw

Total

Cap.

Sens
Cap.

Kw

1203

22.2

32.77

15.48

8.36

30.67

14.52

9.29

28.56

13.56

10.23

26.46

12.60

11.17

24.35

11.64

12.10

19.4

30.23

18.70

7.82

28.17

17.90

8.73

26.11

17.10

9.64

24.05

16.31

10.55

21.99

15.51

11.46

16.7

27.52

23.00

7.46

26.07

21.73

8.30

24.62

20.45

9.14

23.17

19.18

9.98

21.72

17.91

10.82

13.9

26.59

24.96

7.18

24.98

23.20

8.06

23.38

21.43

8.94

21.77

19.67

9.83

20.17

17.91

10.71

1416

22.2

34.17

17.16

8.63

31.91

16.15

9.58

29.65

15.14

10.53

27.39

14.14

11.48

25.13

13.13

12.43

19.4

31.36

21.95

8.08

29.28

20.81

9.01

27.20

19.66

9.93

25.12

18.52

10.86

23.03

17.38

11.78

16.7

28.62

26.83

7.53

26.96

25.02

8.49

25.30

23.20

9.44

23.65

21.39

10.40

21.99

19.58

11.35

13.9

28.62

26.83

7.53

26.96

25.02

8.49

25.30

23.20

9.44

23.65

21.39

10.40

21.99

19.58

11.35

1628

22.2

35.01

18.42

8.82

32.73

17.46

9.77

30.46

16.50

10.73

28.18

15.54

11.69

25.90

14.59

12.64

19.4

32.19

24.67

8.28

30.10

23.35

9.21

28.00

22.04

10.14

25.91

20.72

11.07

23.81

19.40

11.99

16.7

30.24

28.49

7.89

28.44

26.54

8.86

26.64

24.60

9.84

24.84

22.65

10.81

23.03

20.71

11.78

13.9

30.24

28.49

7.89

28.44

26.54

8.86

26.64

24.60

9.84

24.84

22.65

10.81

23.03

20.71

11.78

Sensible heat capacities shown are based on 26.7°C DB entering air at the evaporator coil. For sensible heat capacities at other 
than 26.7°C DB, deduct 44.32 W per 47 L/S of evaporator coil air for each degree below 26.7°C, or add 44.32 W per 47 L/S of 
evaporator coil air per degree above 26.7°C.

PCB090-5 (E

NGLISH

 U

NITS

)

Sensible heat capacities shown are based on 80°F DB entering air at the evaporator coil. For sensible heat capacities at other 
than 80°F DB, deduct 84 BTU/h per 100 CFM of evaporator coil air for each degree below 80°F, or add 84 BTU/h per 100 CFM of 
evaporator coil air per degree above 80°F.

Содержание PCB090-5

Страница 1: ...nized steel powder coated drain pan with 3 4 19mm NPT condensate connection Belt driven variable pitch sheave permits multi speed adjustment Centrifugal fan for quiet and efficient operation Filters 2...

Страница 2: ...24 610 24 610 22 559 Motor Horsepower kW 1 2 0 37 1 2 0 37 1 2 0 37 Outdoor CFM Nominal L S 4300 2030 6100 2880 7000 3300 Condenser Coil Qty 1 1 1 Face Area Total Ft m 15 6 1 45 23 8 2 21 23 8 2 21 R...

Страница 3: ...dimensions in inches and millimeters Drawings are not to scale Note The Horizontal Conversion Kit is required to convert a factory duct configuration downflow to a horizontal duct configuration as sho...

Страница 4: ...265 13 1 7 3 19 6 10 9 26 2 14 6 5000 2360 12 6 7 0 18 8 10 4 25 2 14 0 5200 2454 12 1 6 7 18 1 10 1 24 2 13 4 5400 2548 11 6 6 4 17 4 9 7 23 3 12 9 5600 2643 11 2 6 2 16 8 9 3 22 5 12 5 5800 2737 10...

Страница 5: ...1159 1 65 1259 1 87 1324 2 09 1384 2 31 Notes Selections in ITALICS require a field drive change See following table below for drive ranges Table includes all internal pressure drops including cabinet...

Страница 6: ...8 1034 1 91 1105 2 26 1171 2 26 1233 2 99 3600 706 0 83 805 1 10 894 1 39 975 1 71 1051 2 05 1121 2 41 1188 2 78 1249 3 17 3800 733 0 95 829 1 23 916 1 53 995 1 85 1069 2 20 1139 2 57 1204 2 95 1266 3...

Страница 7: ...08 2 12 1081 2 48 1150 2 86 1215 3 26 1277 3 68 1337 4 12 4600 874 1 63 957 1 97 1034 2 32 1105 2 69 1172 3 08 1236 3 49 1297 3 92 1356 4 37 4800 904 1 82 986 2 17 1060 2 54 1129 2 92 1195 3 32 1258 3...

Страница 8: ...4 C 35 0 C 40 6 C 46 1 C L S WB Total Cap Sens Cap Kw Total Cap Sens Cap Kw Total Cap Sens Cap Kw Total Cap Sens Cap Kw Total Cap Sens Cap Kw 1203 22 2 32 77 15 48 8 36 30 67 14 52 9 29 28 56 13 56 1...

Страница 9: ...22 2 46 65 25 03 10 50 43 81 23 49 11 85 40 96 21 94 13 20 38 11 20 39 14 55 35 26 18 84 15 90 19 4 42 90 33 53 9 86 40 28 31 41 11 17 37 66 29 29 12 48 35 04 27 18 13 78 32 41 25 06 15 09 16 7 40 29...

Страница 10: ...2 191 1 174 8 14 77 180 5 164 7 17 00 169 8 154 6 19 23 159 1 144 5 21 46 148 4 134 4 23 68 57 191 1 174 8 14 77 180 5 164 7 17 00 169 8 154 6 19 23 159 1 144 5 21 46 148 4 134 4 23 68 6440 72 233 9 1...

Страница 11: ...b for equipment in the down discharge application Curb includes provisions for duct attachment prior to setting unit Curb is shipped knocked down with all necessary hardware and gasket material MANUAL...

Страница 12: ...every unit is run tested before it leaves the factory That s why we know there s no better quality Visit our website at www goodmanmfg com for information on Goodman Products Customer Services Parts...

Отзывы: