Introduction

This booklet contains the installation and operating instructions for 

your modular blower cabinet. All warnings and precautions within 

this booklet must be observed.  Improper installation can result in 

problems ranging from noisy operation to property or equipment 

damages, dangerous conditions that could result in injury or per

-

sonal property damage and that are not covered by the warranty.  

Read this booklet and any instructions packaged with accessories 

prior to installation. Give this booklet to the user and explain its 

provisions. The user should retain this booklet for future reference. 

Electrostatic Discharge (ESD) Precautions 

NOTE:

  Discharge body’s static electricity before touching unit.  An 

electrostatic discharge can adversely affect electrical components.

Use the following precautions during modular blower installation 

and servicing to protect the integrated control module from dam

-

age.  By putting the modular blower, the control, and the person 

at the same electrostatic potential, these steps will help avoid 

exposing the integrated control module to electrostatic discharge.  

This procedure is applicable to both installed and uninstalled (un

-

grounded) blowers.

1.  Disconnect all power to the blower.  Do not touch the 

integrated control module or any wire connected to the 

control prior to discharging your body’s electrostatic charge 

to ground.

2.  Firmly  touch  a  clean,  unpainted,  metal  surface  of  the 

modular blower near the control.  Any tools held in a 

person’s hand during grounding will be discharged.

3.  Service integrated control module or connecting wiring 

following the discharge process in step 2.  Use caution not 

to recharge your body with static electricity; (i.e., do not 

move or shuffle your feet, do not touch ungrounded objects, 

etc.).  If you come in contact with an ungrounded object, 

repeat step 2 before touching control or wires.

4.  Discharge your body to ground before removing a new 

control from its container.  Follow steps 1 through 3 if 

installing the control on a blower.  Return any old or new 

controls to their containers before touching any ungrounded 

object.

Checking Product Received

Upon receiving the unit, inspect it for damage from shipment. 

Claims for damage, either shipping or concealed, should be filed 

immediately with the shipping company. Check the unit model 

number, specifications, electrical characteristics and accessories 

to determine if they are correct. In the event an incorrect unit is 

shipped, it must be returned to the supplier and must NOT be in

-

stalled. The manufacturer assumes no responsibility for installation 

of incorrectly shipped units.

Replacement Parts

Ordering Parts

When reporting shortages or damages, or ordering repair parts, 

give the complete unit model and serial numbers as stamped on 

the unit’s nameplate. 
Replacement parts for this appliance are available through your 

contractor or local distributor. For the location of your nearest dis

-

tributor, consult the white business pages, the yellow page section 

of the local telephone book or contact:

HOMEOWNER SUPPORT

GOODMAN MANUFACTURING COMPANY, L.P.

19001 KERMIER ROAD
WALLER, TEXAS 77484

(877) 254-4729

Important Safety Instructions  

Recognize Safety Symbols, Words, and Labels

The following symbols and labels are used throughout this man

-

ual to indicate immediate or potential hazards. It is the owner’s 

responsibility to read and comply with all safety information and 

instructions accompanying these symbols.  Failure to heed safety 

information increases the risk of property damage, product damage, 

personal injury or death.

HIGH VOLTAGE!

D

ISCONNECT

 ALL 

POWER

 

BEFORE

 

SERVICING

M

ULTIPLE

 

POWER

 

SOURCES

 

MAY

 

BE

 

PRESENT

. F

AILURE

 

TO

 

DO

 

SO

 

MAY

 

CAUSE

 

PROPERTY

 

DAMAGE

PERSONAL

 

INJURY

 

OR

 

DEATH

.

WARNING

Содержание MBVC 1 Series

Страница 1: ...MENT THE MANUFACTURER WILL NOT BE RESPONSIBLE FOR ANY INJURY OR PROPERTY DAMAGE ARISING FROM IMPROPER SERVICE OR SERVICE PROCEDURES IF YOU SERVICE THIS UNIT YOU ASSUME RESPONSIBILITY FOR ANY INJURY OR...

Страница 2: ...edobjects etc If you come in contact with an ungrounded object repeat step 2 before touching control or wires 4 Discharge your body to ground before removing a new control from its container Follow st...

Страница 3: ...ons Internal algorithms will provide 2 stage or inverter Air Conditioner or Heat Pump functionality based on these simple inputs With built in Bluetooth operation the CoolCloud HVAC phone appli cation...

Страница 4: ...f the blower cabinet Figure 3 NOTE All panels should be in place when installing the unit NOTE Supply ductwork for counterflow applications must be Class I However if combustible ductwork is used shee...

Страница 5: ...disconnected during shipping and handling 208 230 Volt Line Connections If heater kits will not be installed remove the proper size knockout for the electrical conduit connection Connect electrical c...

Страница 6: ...et on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Actual screens may look different based on the mobile device be...

Страница 7: ...show Release the RECAL button 7 Press and hold the RECALL button again for another 5 seconds the 7 Segment display should show Release the RECALL button 8 Press and hold BOTH the RECALL AND TEST butt...

Страница 8: ...he system has already terminated charge mode Pressing the LEARN button will exit the menus If after pressing the RECALL button at step 8 the 7 Segment displays still show press RECALL to change the di...

Страница 9: ...e stage Heat Pumps for two stage Air Conditioners and for 2 stage Heat Pumps 4 Go to the Tonnage Units Menu and select the tonnage valuethatcorrespondstothedesiredairflowfortheoutdoor unit See the fol...

Страница 10: ...or the thermostat energizes this terminal when dehumidifcation is required set the control board Dehum Logic Menu to using the push buttons or CoolCloud HVAC phone application If the humidistat opens...

Страница 11: ...ermostatto ensureGsignal isenergized during accessory operation Figure 15 4 Select the appropriate fan only airflow for the accessory using the indoor unit push button menus or the CoolCloud HVAC phon...

Страница 12: ...in a person s hand during grounding will be discharged 3 Service integrated control module or connecting wiring following the discharge process in step 2 Use caution not to recharge your body with sta...

Страница 13: ...disconnected wiring connection at circulator motor power leads Open circuit in inductor or loose wiring connection at inductor 3 4 Hp and 1 Hp models only Failed circulator blower motor Tighten or co...

Страница 14: ...necessary No Air Handler operation Circulator blower motor shuts down for over or under voltage condition Circulator blower motor shuts down due to over temperature condition on power module High or...

Страница 15: ...Airflow Trim default 0 Cooling Airflow Profile setting default profile D shown as 4 Cooling Airflow On Delay Time default 5 seconds Cooling Airflow Off Delay Time default 60 seconds Percentage of hig...

Страница 16: ...the next heat call if the heat pump fails to satisfy the custom target time for this number of consecutive cycles default 20 cycles Menu is enabled if the menu is set to 6 if the addition of low stag...

Страница 17: ...nits Compressor Heat Low Stage Comm Units Compressor Heat High Stage Comm Units Electric Heat Single Stage Electric Heat Low Stage Electric Heat High Stage Defrost Single Stage Electric Heat non comm...

Страница 18: ...r kit size See Menu Navigation and Selection Instructions above Default selection is 0 No Heat Kit Select installed heater kit for heater kit operation NR Not Rated Electric Heat Airflow Table Menu Na...

Страница 19: ...ACED IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A TEMPERATURE RATING OF AT LEAST 105 C USE COPPER CONDUCTORS ONLY 4 UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N E C AND LOCAL CODES 5 TO REC...

Страница 20: ...and drain pan tab lets contain corrosive chemicals that can be harmful to aluminum tube and fin evaporator coils Even a one time application of these corrosive chemicals can cause premature aluminum...

Страница 21: ...21 THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 22: ...22 THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 23: ...23 THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 24: ...p www amana hac com about us contact us You can also scan the QR code on the right for the product brand you purchased to be directed to the feedback page GOODMAN BRAND AMANA BRAND GOODMAN BRAND AMANA...

Отзывы: