6
HEAT PUMP SPECIFICATIONS
GSH130[18-60]*A*
(1)
Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes.
(2)
May use fuses or HACR-type circuit breakers of the same size as noted.
GSH 3-PHASE
(1)
Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.
(2)
Maximum Overcurrent Protection Device: May use fuses or HACR type Circuit Breakers of the same size as noted.
GSH130[18-60]1
G
S
H13
036
3A*
G
S
H13
048
3A*
G
S
H13
060
3A*
G
S
H13
048
4A*
G
S
H13
060
4A*
Cooling Capacity, BTUH
35,000
45,000
55,500
45,000
55,500
Compressor
R.L. Amps
9.0
12.4
17.3
5.8
6.7
L.R. Amps
65.5
88.0
123.0
44.0
49.5
Loss of Charge Pressure Switch
Open / Close
7 PSIG/25 PSIG 7 PSIG/25 PSIG 7 PSIG/25 PSIG 7 PSIG/25 PSIG 7 PSIG/25 PSIG
Condenser Fan Motor
Horsepower
1/4
1/4
1/6
1/4
1/6
F.L. Amps
1.6
1.6
1.1
0.8
1.1
Liquid Line, Inches O.D.
3/8"
3/8"
3/8"
3/8"
3/8"
Suction Line, Inches O.D.
7/8"
7/8"
7/8"
7/8"
7/8"
Refrigerant Charge
188
223
233
223
233
Design Subcooling Cooling (°F)
9 + 3
9 + 3
9 + 3
9 + 3
9 + 3
Power Supply
208/230-60-3
208/230-60-3
208/230-60-3
460/60/3
460/60/3
Minimum Circuit Ampacity
(1)
12.0
17.2
22.7
8.0
9.0
Maximum Overcurrent Device
(2)
20
20
40
15
15
Electrical Conduit Size
Power Supply (Inches)
1/2 or 3/4
1/2 or 3/4
1/2 or 3/4
1/2 or 3/4
1/2 or 3/4
Approximate Shipping Weight
207
225
266
225
266
G
S
H
1
30181A
*
G
S
H
1
30191A
*
G
S
H
1
30241A
*
G
S
H
1
30251A
*
G
S
H
1
30301A
*
G
S
H
1
30311A
*
G
S
H
1
30361A
*
G
S
H
1
30421A
*
G
S
H
1
30481A
*
Cooling Capacity, BTUH
18,000
18,000
23,000
23,000
28,000
28,000
35,000
40,000
45,000
Compressor
R.L. Amps
6.2
9.0
9.2
10.9
10.8
12.2
8.3
16.5
17.9
L.R. Amps
34
41
43
54
60
63
48
95
104
Loss of Charge Pressure Switch
Open / Close
7 PSIG/25 PSIG 7 PSIG/25 PSIG 7 PSIG/25 PSIG 7 PSIG/25 PSIG 7 PSIG/25 PSIG 7 PSIG/25 PSIG 7 PSIG/25 PSIG 7 PSIG/25 PSIG 7 PSIG/25 PSIG
Condenser Fan Motor
Horsepower
1/6
1/6
1/6
1/6
1/6
1/6
1/4
1/4
1/4
F.L. Amps
1.5
1.5
1.5
1.5
1.5
1.5
1.6
1.6
1.6
Liquid Line, Inches O.D.
3/8"
3/8"
3/8"
3/8"
3/8"
3/8"
3/8"
3/8"
3/8"
Suction Line, Inches O.D.
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
7/8"
7/8"
7/8"
Refrigerant Charge
127
115
106
117
153
153
188
213
223
Design Subcooling Cooling (°F)
9 + 3
9 + 3
9 + 3
9 + 3
9 + 3
9 + 3
9 + 3
9 + 3
9 + 3
Power Supply
208/230-60-1
208/230-60-1
208/230-60-1
208/230-60-1
208/230-60-1
208/230-60-1
208/230-60-1
208/230-60-1
208/230-60-1
Minimum Circuit Ampacity
(1)
9.3
12.7
13
15.1
15
16.7
16.9
22.3
27.8
Maximum Overcurrent Device
(2)
15
20
20
20
20
20
20
30
40
Electrical Conduit Size
Power Supply (Inches)
1/2 or 3/4
1/2 or 3/4
1/2 or 3/4
1/2 or 3/4
1/2 or 3/4
1/2 or 3/4
1/2 or 3/4
1/2 or 3/4
1/2 or 3/4
Approximate Shipping Weight
193
193
198
207
199
199
207
219
225
G
S
H
130601A
*
55,500
25.0
148
7 PSIG/25 PSIG
1/6
1.1
3/8"
7/8"
233
9 + 3
208/230-60-1
32.3
50
1/2 or 3/4
266