38
EXPANDED PERFORMANCE DATA
MODEL: GSH130311A* / AWB36-XX / AWUF36XX1A*
HEATING OPERATION
Outdoor Ambient Temperature
65
60
55
50
47
45
40
35
30
25
20
17
15
10
5
0
-5
-10
MBh
32.2
30.5
28.7
26.8
25.6
24.8
23.0
21.2
23.7
21.8
20.1
19.0
18.3
16.4
14.5
12.7
10.8
8.9
Delta T
28.4
26.9
25.3
23.6
22.6
21.9
20.3
18.7
20.9
19.3
17.7
16.7
16.1
14.5
12.8
11.2
9.5
7.8
KW
2.55
2.49
2.44
2.39
2.36
2.33
2.28
2.23
2.00
1.95
1.90
1.87
1.86
1.81
1.76
1.71
1.66
1.62
AMPS
12.6
11.7
11.0
10.3
10.0
9.8
9.3
8.8
8.5
8.1
7.7
7.6
7.5
7.1
6.7
6.3
5.9
5.3
COP
3.70
3.58
3.44
3.29
3.18
3.11
2.96
2.79
3.47
3.28
3.09
2.97
2.89
2.66
2.42
2.17
1.90
1.61
EER
12.6
12.2
11.8
11.2
10.9
10.6
10.1
9.5
11.8
11.2
10.6
10.1
9.9
9.1
8.3
7.4
6.5
5.5
HI PR
254
243
234
224
218
214
206
198
189
181
174
170
166
160
154
148
142
137
LO PR
76
71
66
61
57
55
51
45
41
36
32
30
29
24
21
18
15
12
EXPANDED PERFORMANCE DATA
MODEL: GSH130301A* / ARUF42-00*-01* / ARUF30301A*
HEATING OPERATION
Outdoor Ambient Temperature
65
60
55
50
47
45
40
35
30
25
20
17
15
10
5
0
-5
-10
MBh
33.7
31.9
30.0
28.1
26.8
26.0
24.1
22.2
17.4
16.1
14.8
14.0
13.5
12.1
10.7
9.4
8.0
6.5
Delta T
29.7
28.1
26.5
24.7
23.6
22.9
21.3
19.6
15.4
14.2
13.1
12.3
11.9
10.7
9.5
8.2
7.0
5.8
KW
2.41
2.36
2.32
2.27
2.24
2.22
2.18
2.13
2.08
2.04
1.99
1.96
1.95
1.90
1.85
1.81
1.76
1.72
AMPS
11.1
10.3
9.6
9.1
8.7
8.6
8.1
7.7
7.3
7.0
6.7
6.5
6.4
6.1
5.7
5.3
4.9
4.4
COP
4.09
3.95
3.79
3.62
3.50
3.42
3.24
3.05
2.45
2.31
2.18
2.09
2.03
1.86
1.69
1.51
1.32
1.11
EER
14.0
13.5
13.0
12.4
11.9
11.7
11.1
10.4
8.4
7.9
7.4
7.1
6.9
6.4
5.8
5.2
4.5
3.8
HI PR
234
224
216
206
202
198
190
182
175
167
160
156
154
148
142
136
131
127
LO PR
76
70
66
61
57
55
51
45
41
36
32
30
29
24
21
18
15
12
EXPANDED PERFORMANCE DATA
MODEL: GSH130251A* / AWB36-XX / AWUF36XX1A*
HEATING OPERATION
Outdoor Ambient Temperature
65
60
55
50
47
45
40
35
30
25
20
17
15
10
5
0
-5
-10
MBh
28.4
26.9
25.3
23.7
22.6
21.9
20.3
18.8
17.1
15.7
14.5
13.7
13.2
11.8
10.5
9.1
7.8
6.4
Delta T
32.1
30.4
28.6
26.7
25.5
24.7
23.0
21.2
19.3
17.8
16.4
15.5
14.9
13.4
11.8
10.3
8.8
7.2
KW
2.31
2.27
2.23
2.18
2.16
2.14
2.10
2.05
1.90
1.86
1.82
1.80
1.78
1.74
1.70
1.66
1.62
1.58
AMPS
11.1
10.3
9.7
9.1
8.8
8.7
8.2
7.8
7.5
7.2
6.9
6.8
6.7
6.4
6.0
5.7
5.3
4.9
COP
3.59
3.47
3.33
3.17
3.07
3.00
2.84
2.67
2.62
2.48
2.33
2.23
2.17
1.99
1.81
1.61
1.41
1.19
EER
12.3
11.8
11.4
10.8
10.5
10.2
9.7
9.1
9.0
8.5
8.0
7.6
7.4
6.8
6.2
5.5
4.8
4.0
HI PR
178
170
164
157
153
150
144
138
133
127
122
119
117
112
108
103
100
96
LO PR
76
71
66
61
58
55
51
45
41
37
32
30
29
24
21
18
15
12
High pressure is measured at the suction service valve ( the larger valve).
AMPS = Outdoor unit amps (comp.+fan)
Low pressure is measured at the gauge port connection.
KW = Total system power
Calculations are based on nominal CFM and 70 °F indoor dry bulb.
HEATING PERFORMANCE DATA