GMVS96-U Airflow Data
Minimum Filter Sizes
GMVS96
0603BU
GMVS96
0805CU
Filter Size (in²) (Qty)
(1) 16 x 25 (side or
bottom)
(1) 20 x 25 (bottom) or
(2) 16 x 25 (side)
Note: Other size filters of equal or greater dimensions may be used. Filters may also be
centrally located.
Model
Description
GMVS96
0603BU
GMVS96
0805CU
CVENT-2
Concentric Vent Kit (2")
√
√
CVENT-3
Concentric Vent Kit (3")
√
√
RF000142
Drain Kit -Horizontal Left Vertical Flue
√
√
EFR02
External Filter Rack with 16"x25"
Permanent Filter
√
√
0170K00000S
Flush Mount Vent Kit - 3" or 2"
√
√
0170K00001S
Flush Mount Vent Kit - 2"
√
√
Accessories
MODEL / TEMP RISE RANGE
GMVS960603BUA*
30-60 (45)
GMVS960805CUA*
30-60-(45)
CFM
RISE
CFM
RISE
Recommended CFM for Heat Mode / Expected Temperature Rise
1185
45
1580
45
Lowest Recommended CFM for Heat Mode / Expected
Temperature Rise
889
60
1185
60
Maximum CFM for Heat Mode / Expected Temperature Rise
1400 (MAX
CAPABLE CFM)
38
2200 (MAX
CAPABLE CFM)
32
Note:
To Set Heating CFM Using Push Buttons; 1) Scroll using Left or Right push buttons until gAF appears on the 7 segment display.
2) Press & release center button & display will show current heating airflow expressed as a percentage of max CFM.3) Press & release Left or
Right button until desired percentage appears. 4) Press & release center button once more to select the displayed percentage.
5) CFM may be trimmed further by using the gTF menu.
(CFM & Temperature Rise vs. External Static Pressure)