PRODUCT IDENTIFICATION

2

The model and manufacturing number are used for positive identification of component parts used in manufacturing.
Please use these numbers when requesting service or parts information.

WARNING

WARNING

WARNING

WARNING

HIGH VOLTAGE!
Disconnect ALL power before servicing or installing this unit. Multiple
power sources may be present. Failure to do so may cause property
damage, personal injury or death.

Installation and repair of this unit should be performed ONLY by individu-
als meeting the requirements of an "entry level technician" as specified
by the Air Conditioning and Refrigeration Institute (ARI). Attempting to
install or repair this unit without such background may result in product
damage, personal injury or death.

WARNING

WARNING

Goodman will not be responsibile for any injury or property damage arising
from improper service or service procedures. If you install or perform
service on this unit, you assume responsibility for any personal injury or
property damage which may result. Many jurisdictions require a license to
install or service heating and air conditioning equipment.

Furnace Type

V: Variable Speed - 2 Stage

Product Type

G:  Goodman Brand

Supply Type

Nominal Input

Model Family

G

M

 V

95 045

3

B

X

A

Additional Features

N: Natural Gas

X:

Low NOx

Airflow Capability

Cabinet Width

Design Series

A: Initial Release

045:

45,000 Btuh

070:

70,000 Btuh

090:

90,000 Btuh

115:

115,000 Btuh

3:

1200

4:

1600

5:

2000

95: 95% AFUE

C: Counterflow/Horizontal

M: Upflow/Horizontal

B: 17 1/2"

C: 21"

D: 24 1/2"

Содержание GMV95 Series

Страница 1: ...as provided in the Service Manual Refer to the appropriate Parts Catalog for part number information Copyright 2005 2007 Goodman Manufacturing Company L P RT6612012Rev 1 June2007 This manual is to be...

Страница 2: ...his unit without such background may result in product damage personal injury or death WARNING WARNING Goodman will not be responsibile for any injury or property damage arising from improper service...

Страница 3: ...vice that is not design certified by Goodman for use with this unit Serious property damage personal injury reduced unit performance and or hazardous conditions may result from the use of such non app...

Страница 4: ...ic ignition device to light the burners and an induced draft blower to exhaust combustion products An interlock switch prevents furnace operation if the blower door is not in place Keep the blower acc...

Страница 5: ...Electrical Connection Inlets Alternate 18 Coil Front Cover Pressure Tap 19 Coil Front Cover Drain Port 20 Drain Line Penetrations 21 Drain Trap 22 Blower Door Interlock Switch 23 Inductor NotAll Model...

Страница 6: ...FLANGES AIR DISCHARGE AIR DISCHARGE Cabinet Size A B C D E 13 5 8 17 1 2 20 7 8 All dimensions are in inches 24 1 2 12 1 8 16 19 3 8 12 15 16 15 15 16 20 7 16 GMV950453BX GMV950904CX GMV950905DX GMV95...

Страница 7: ...IRE LOW FIRE HIGH FIRE LOW FIRE HIGH FIRE LOW FIRE HIGH FIRE GMV950453BX GMV950704CX 0 10 0 10 20197308 0 30 0 75 11177113 PURPLE PINK 0 10 0 10 0 22 0 55 HAPS28 11177115 GREEN YELLOW GMV950905DX GMV9...

Страница 8: ...GMV951155DX 2 ROLLOUT LIMIT SWITCHES Part Number 10123535 10123537 10123536 10123533 Open Setting F 150 140 180 200 GMV950453BX 2 GMV950704CX 2 GMV950905DX 2 GMV951155DX 2 AUXILIARY LIMIT SWITCHES Par...

Страница 9: ...al slab only 6 R 22orR 410A 2 R 22 4 R 410A Refrigerant Revision A Revision Coil Matches Alarge array ofAmana brand coils are available for use with the GMV95 furnaces in either upflow or horizontal a...

Страница 10: ...Permanent Minimum Filter Area in2 Based on 600 ft min filter face velocity Thermostat Man Auto Programmable Cool Heat Batt Powered Batt Bkup 1213406 Man Or Auto Yes 2 3 No No 1213407 Man Changeover Y...

Страница 11: ...43 55 43 55 43 55 43 55 Number of Burners 2 3 4 5 Vent Connector Diameter inches 2 2 3 3 Combustion Air Connector Diameter inches 2 2 3 3 Shipping Weight lbs 133 133 172 184 Refer to airflow charts o...

Страница 12: ...71 46 Plus 924 1331 46 Minus 540 778 52 Minus 828 1192 51 Normal 600 864 47 Normal 920 1325 46 Plus 660 950 43 Plus 1012 1457 42 Minus 585 842 48 Minus 900 1296 47 Normal 650 936 43 Normal 1000 1440 4...

Страница 13: ...lus 880 Minus 720 Minus 720 Minus 990 Minus 990 Normal 800 Normal 800 Normal 1100 Normal 1100 Plus 880 Plus 880 Plus 1210 Plus 1210 Minus 900 Minus 990 Minus 1260 Minus 1260 Normal 1000 Normal 1100 No...

Страница 14: ...oses only 6 Motor CFM minimum GMV95 Continuous Fan Speed Chart Cooling Speed Tap Adjust Tap CFM at 1 8 w c ESP Cooling Speed Tap Adjust Tap CFM at 1 8 w c ESP Minus 380 Minus 380 Normal 380 Normal 380...

Страница 15: ...4 3 2 1 4 3 2 1 4 3 2 1 Ramping Profile Tap A Ramping Profile Tap B Ramping Profile Tap C Ramping Profile Tap D Ramping Profiles indicates factory setting 8 7 8 7 8 7 6 5 6 5 6 5 6 5 O N O F F O N O...

Страница 16: ...30 140 150 100 90 80 70 60 50 40 30 20 10 OUTPUT BTU HR x 1000 BTU OUTPUT vs TEMPERATURE RISE CHART TEMPERATURE RISE 600 CFM 700 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 CFM FORMULAS BTU OUTPU...

Страница 17: ...L PROTECTIVE DEVICE OPEN SWITCH PRESS SWITCH TEMP FIELD SPLICE FIELD GND NO C FRONT COVER PRESSURE SWITCH MANUAL RESET ROLLOUT LIMIT CONTROLS SINGLE CONTROL ON 45 kBTU PK PINK PLUG CONNECTION BURNER C...

Страница 18: ...CUT FOR 1 2 3 87 4321 87 4321 Intell Ignition TSTAT S4 S3 OFF ON S1 SINGLE TWO ON OFF YL PK VT HOUSING SIDES OF BLOWER AUXILIARY LIMITS PIN 1 PIN 2 BK WH GN GY OR BK WH PIN 6 SCROLL HOUSING GROUND TO...

Страница 19: ...STAGE M P COM MV SWITCH ROLLOUT MVH W2 W2 HUM EAC NEU EAC AIR CLEANER ELECTRONIC INDUCER HUMN HUMIDIFIER W1 G Y R W1 G Y B C TR R TH 24 V A C XFMRN XFMR BLOWER CIRCULATOR HLI HLO PS1 PS2 MVL GND IGNN...

Отзывы: