P
roDuct
s
PeciFications
P
roDuct
s
PeciFications
SS-GME8
www.goodmanmfg.com
5
a
irFlow
D
ata
(CFM & Temperature Rise vs. External Static Pressure)
Model
Motor
Speed
Tons
AC¹
External Static Pressure, (Inches Water Column)
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
CFM
Rise
CFM
Rise
CFM
Rise
CFM
Rise
CFM
Rise
CFM
CFM
CFM
GME8
0603B*B
T1
1½
875
---
793
---
736
---
674
---
592
---
556
509
460
T2
2
1,032
43
965
46
914
49
861
---
810
---
756
712
659
T3
2½
1,217
37
1,153
39
1,098
40
1,051
42
1,009
44
964
918
877
T4
3
1,365
33
1,313
34
1,268
35
1,221
36
1,172
38
1,129 1,086 1,054
T5
3½
1,549
29
1,505
30
1,460
30
1,420
31
1,378
32
1,350 1,305 1,268
GME8
0805C*B
T1
2½
1,268
47
1,198
49
1,151
51
1,092
54
1,041
57
988
932
883
T2
3
1,362
44
1,305
45
1,261
47
1,212
49
1,170
51
1,121 1,074 1,021
T3
3½
1,576
38
1,519
39
1,473
40
1,426
42
1,398
42
1,341 1,290 1,252
T4
4
1,755
---
1,711
35
1,657
36
1,627
36
1,579
38
1,548 1,502 1,463
T5
5
2,183
---
2,128
---
2,094
---
2,060
---
2,014
---
1,992 1,944 1,847
GME8
1005C*B
T1
3
1,466
51
1,415
52
1,357
55
1,306
57
1,248
59
1,202 1,144 1,088
T2
3½
1,642
45
1,596
46
1,552
48
1,499
49
1,449
51
1,388 1,352 1,306
T3
4
1,750
42
1,750
42
1,707
43
1,667
44
1,610
46
1,574 1,531 1,486
T4
4
1,870
40
1,805
41
1,782
42
1,737
43
1,701
44
1,656 1,606 1,571
T5
5
2,297
---
2,297
---
2,224
---
2,106
35
2,014
37
1,896 1,813 1,669
¹ @ 0.5” ESP
Notes
• CFM in chart is without filter(s). Filters do not ship with this furnace, but must be provided by the installer. If the furnace requires two return filters, this
chart assumes both filters are installed.
• All furnaces ship as high-speed cooling and medium-speed heating. Installer must adjust blower cooling and heating speed as needed.
• For most jobs, about 375 - 400 CFM per ton when cooling is desirable.
• INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE.
• This chart is for information only. For satisfactory operation, external static pressure should not exceed value shown on the rating plate.
• The above chart is for U.S. furnaces installed at 0-2000 feet. At higher altitudes, a properly derated unit will have approximately the same temperature rise
at a particular CFM, while ESP at the CFM will be lower.
• Factory Motor Speed Setting: T1 = 1st Stage Ht, T2 = 2nd Stage Ht, T5 = Cooling
• Temperature rise data is based on second-stage heat. First-stage heat is 75% of rise indicated above.