roDuct

 s

PeciFications

P

roDuct

 s

PeciFications

4 www.goodmanmfg.com 

SS-GME8

D

iMensions

M

iniMuM

 c

learances

 

to

 c

oMBustiBle

 M

aterials

Sides

Rear

Front

Bottom

Vent

Top

SW

B

1

0

3

C

6

1

1

C = If placed on combustible floor, the floor MUST be wood ONLY.

Notes:
•  For servicing or cleaning, a 24” front clearance is recommended.
•  Unit connections (electrical, flue, and drain) may necessitate greater clearances than the minimum clearances listed above.
•  In all cases, accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater.
•  Refer to the appropriate USA and Canadian codes:

◊  In the USA: the National Fuel Gas Code NFPA 54 / ANSI Z223.1
◊  In Canada: the Canada National Standard of Canada, CAN/CSA B149.1 and CAN/CSA B142.2

PRODUCT DIMENSIONS

8

AMVC8/GMVC8_____X*

Alt. Gas Inlet

High Voltage Inlet

Low Voltage

Alt. Gas Inlet

Alt. High Voltage

Alt. LowVoltage

MODELS

A

B

AMVC80704BX**

GMVC80704BX**

17-1/2

16

AMVC80905CX**

AMVC81155CX**

GMVC80905CX**

GMVC81155CX**

21

19-1/2

All dimensions are in inches.

Model

A

B

GME80603B**

17½”

16”

GME80805C**

21”

19½”

GME81005C**

21”

19½”

Содержание GME80603B Series

Страница 1: ...tempera ture without an outdoor temperature sensor Certain models available with low NOx emissions Cabinet Features Fully insulated heavy gauge steel cabinet with durable baked enamel finish Foil face...

Страница 2: ...tal NOx D Dedicated Down ow N Natural Gas H High Air ow X Low NOx K Dedicated Up ow M Up ow Horizontal Cabinet Width A 14 Descrip2on B 17 V Two Stage Variable speed C 21 H Two Stage Mul speed D 24 S S...

Страница 3: ...upon Isolated Combustion System ICS Vent diameter may vary depending upon vent length Refer to the latest editions of the National Fuel Gas Code NFPA 54 ANSI Z223 1 in the USA and the Canada National...

Страница 4: ...ibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater Refer to the appropriate USA and Canadian codes In the USA the National Fuel Gas Co...

Страница 5: ...1 352 1 306 T3 4 1 750 42 1 750 42 1 707 43 1 667 44 1 610 46 1 574 1 531 1 486 T4 4 1 870 40 1 805 41 1 782 42 1 737 43 1 701 44 1 656 1 606 1 571 T5 5 2 297 2 297 2 224 2 106 35 2 014 37 1 896 1 813...

Страница 6: ...60 70 80 90 110 120 100 130 140 150 100 90 80 70 60 50 40 30 20 10 OUTPUT BTU HR x 1000 BTU OUTPUT vs TEMPERATURE RISE CHART TEMPERATURE RISE 600 CFM 700 900 1000 1100 1200 1400 1600 1800 2000 2200 2...

Страница 7: ...ect to change Always refer to the wiring diagram or the unit for the most up to date wiring W arning High Voltage Disconnect all power before servicing or installing this unit Multiple power sources m...

Страница 8: ...er This furnace is capable of the following heating modes Single Stage Factory Setting Modified Two Stage Fixed 5 Min Low Stage Auto Time 1 12 Min Low Stage Start Call for Heat Safety Circuit Check St...

Отзывы: