8
www.goodmanmfg.com
SS-GMH95
SS-GMH95
www.goodmanmfg.com
9
P
roduct
S
PecificationS
P
roduct
S
PecificationS
GCH95 a
irFlow
d
ata
(CFM & Temperature Rise vs. External Static Pressure)
Model
Motor
Speed
Tons
AC¹
External Static Pressure, (Inches Water Column)
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
CFM
Rise
CFM
Rise
CFM
Rise
CFM
Rise
CFM
Rise
CFM
CFM
CFM
GCH95
0453BX
High
3
1,415
28
1,352
30
1,290
31
1,196
34
1,127
36
1,035
936
825
Med
2.5
1,221
33
1,178
34
1,127
36
1,073
38
1,007
40
932
834
733
Med-Lo
2
1,034
39
1,000
40
976
41
935
43
881
46
818
733
662
Low
1.5
860
47
845
48
812
50
783
51
740
54
682
619
534
GCH95
0703BX
High
3
1,431
42
1,368
44
1,296
47
1,228
49
1,150
53
1,055
962
860
Med
2.5
1,212
50
1,182
51
1,138
53
1,091
55
1,019
59
944
871
769
Med-Lo
2
1,002
60
978
62
956
63
921
66
878
69
825
738
647
Low
1.5
813
74
805
75
790
76
759
80
726
83
689
644
605
GCH95
0704CX
High
4
1,755
34
1,674
36
1,632
37
1,510
40
1,423
42
1,325
1,241
1,116
Med
3.5
1,656
36
1,585
38
1,536
39
1,429
42
1,355
45
1,268
1,145
1,059
Med-Lo
3
1,551
39
1,488
41
1,427
42
1,353
45
1,290
47
1,195
1,100
1,017
Low
2.5
1,286
47
1,258
48
1,241
49
1,185
51
1,112
54
1,067
983
886
GCH95
0904CX
High
4
1,734
46
1,652
49
1,578
51
1,508
53
1,413
57
1,336
1,248
1,154
Med
3.5
1,642
49
1,558
52
1,487
54
1,418
57
1,336
60
1,243
1,164
1,039
Med-Lo
3
1,522
53
1,458
55
1,396
58
1,321
61
1,253
64
1,182
1,101
986
Low
2.5
1,287
63
1,244
65
1,184
68
1,148
70
1,098
73
1,034
953
849
GCH95
0905DX
High
5
2,189
37
2,109
38
2,025
40
1,948
41
1,862
43
1,757
1,644
1,537
Med
4
1,885
43
1,831
44
1,776
45
1,711
47
1,637
49
1,539
1,453
1,346
Med-Lo
3.5
1,665
48
1,627
50
1,584
51
1,524
53
1,462
55
1,400
1,323
1,220
Low
3
1,474
55
1,440
65
1,401
57
1,356
59
1,310
61
1,255
1,193
1,109
GCH93
1155DX
High
5
2,134
46
2,103
47
2,029
48
1,941
51
1,906
51
1,818
1,733
1,625
Med
4
1,678
58
1,643
60
1,643
60
1,577
62
1,527
64
1,489
1,423
1,339
Med-Lo
3.5
1,453
68
1,440
68
1,426
69
1,363
72
1,349
73
1,314
1,253
1,205
Low
3
1,259
78
1,239
79
1,220
80
1,181
83
1,159
85
1,118
1,082
1,015
¹ @0.5” ESP
Notes:
• CFM in chart is without filter(s). Filters do not ship with this furnace, but must be provided by the installer.
• All furnaces ship as high-speed cooling and medium-speed heating. Installer must adjust blower cooling & heating speed as needed.
• For most applications, about 400 CFM per ton when cooling is desirable.
• INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE.
• The chart is for information only. For satisfactory operation, external static pressure should not exceed value shown on the rating plate.
• The above chart is for furnaces installed at 0-2000 feet. At higher altitudes, a properly de-rated unit will have ap-
proximately the same temperature rise at a particular CFM, while ESP at the CFM will be lower.