background image

GMH95 & GCH95

M

ulti

-P

osition

, t

wo

-s

taGe

, M

ulti

-s

Peed

 G

as

 F

urnaCes

u

P

 

to

 96% aFue

SS-GMH95

www.goodmanmfg.com

11/12

Supersedes 9/12

Standard Features

•  Dual-diameter tubular heat exchanger
•  Two-stage gas valve convertible technology allows installer  

to activate the two-stage valve with the flip of a dipswitch 

•  110V Silicon Nitride igniter designed for long igniter life
•  Furnace control board with self-diagnostics, color-

coded low-voltage terminals, and provisions for 
electronic air cleaner and 24-volt humidifiers

•  Control board stores the last five diagnostic codes 

in memory; simple push-button activation out-
puts the fault history to a flashing red LED

•  Low constant fan allows homeowner to activate the low 

heat speed to efficiently circulate air throughout the home

•  Self-adjusting feature automatically adjusts to 

high- or low-stage operation based on outside tem-
perature without an outdoor temperature sensor

•  Dual-certified for sealed combustion direct vent (2-pipe)  

or non-direct vent (1-pipe) applications

•  All models comply with California NOx emissions standards

Contents

Nomenclature ....................................... 2
Product Specifications .......................... 3
Dimensions ........................................... 5

Airflow Data ...........................................7

Wiring Diagrams ................................... 9

Accessories ...........................................11

Cabinet Features

•  Fully insulated, heavy-gauge steel cabi-

net with durable baked-enamel finish

•  Foil-faced insulation lines the heat exchanger
•  Designed for multi-position installation: 

GMH95: upflow, horizontal left or right;  
GCH95/GCH9: downflow, horizontal left or right

•  Easy-to-install top venting is standard; alternate flue/vent  

located on the right (GMH95)

•  Airtight solid bottom for side-return applications and easy-cut 

tabs for effortless removal in bottom air inlet applications

•  Convenient left or right connection  

for gas and electric service

•  Coil and furnace fit flush for most installations

*  Complete  warranty  details  available  from  your  local  dealer  or  at  www.goodmanmfg.com.  To  receive  the  Lifetime  Heat 

Exchanger Limited Warranty (good for as long as you own your home), 10-Year Unit Replacement Limited Warranty and 10-
Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not 
required in California or Québec.

Содержание GCH91155DX

Страница 1: ...rect vent 1 pipe applications All models comply with California NOx emissions standards Contents Nomenclature 2 Product Specifications 3 Dimensions 5 Airflow Data 7 Wiring Diagrams 9 Accessories 11 Cabinet Features Fully insulated heavy gauge steel cabi net with durable baked enamel finish Foil faced insulation lines the heat exchanger Designed for multi position installation GMH95 upflow horizont...

Страница 2: ...icated Downflow N Natural Gas H High Airflow X Low NOx K Dedicated Upflow M Upflow Horizontal Cabinet Width A 14 Description B 17 V Two Stage Variable speed C 21 H Two Stage Multi speed D 24 S Single Stage Multi speed E Two Stage EEM Motor Maximum CFM 0 5 ESP 3 1200 5 2000 AFUE 4 1600 95 95 9 93 MBTU h 8 80 045 45 000 115 115 000 070 70 000 140 140 000 090 90 000 12 A B 11 X 10 M 2 1 G H 3 4 6 7 8...

Страница 3: ...bove 2 000 reduce input rating 4 for each 1 000 above sea level DOE AFUE based upon Isolated Combustion System ICS Installer must supply one or two PVC pipes one for combustion air optional and one for the flue outlet required Vent pipe must be either 2 or 3 in diameter depending upon furnace input number of elbows length of run and installation 1 or 2 pipes The optional Combustion Air Pipe is dep...

Страница 4: ...put rating 4 for each 1 000 above sea level DOE AFUE based upon Isolated Combustion System ICS Installer must supply one or two PVC pipes one for combustion air optional and one for the flue outlet required Vent pipe must be either 2 or 3 in diameter depending upon furnace input number of elbows length of run and installation 1 or 2 pipes The optional Combustion Air Pipe is dependent on installati...

Страница 5: ...alve Installations using a bottom return Failure to unfold duct flanges will reduce airflow area by approximately 18 This could result in performance and noise issues Minimum Clearances to Combustible Materials Position Sides Rear Front Bottom Flue Top Upflow 0 0 1 C 0 1 Horizontal 6 0 1 C 0 4 C If placed on combustible floor the floor MUST be wood ONLY For servicing or cleaning a 24 front clearan...

Страница 6: ... 23 GCH91155DX 24 23 20 21 23 Notes Installer must supply one or two PVC pipes one for combustion air optional and one for the flue outlet required Vent pipe must be either 2 or 3 in diameter depending upon furnace input number of elbows length of run and installation 1 or 2 pipes The optional combustion air pipe is dependent on installation code requirements and must be 2 or 3 diameter PVC Line v...

Страница 7: ...56 1 370 58 1 327 60 1 260 63 1 166 1 078 956 Low 2 5 1 183 67 1 155 69 1 122 71 1 108 72 1 062 75 1 011 931 816 GMH95 0905CXA High 5 2 147 37 2 114 37 2 057 39 2 030 39 1 978 40 1 889 1 784 1 713 Med 4 1 675 47 1 686 47 1 640 48 1 623 49 1 557 51 1 501 1 455 1 360 Med Lo 3 5 1 489 53 1 470 54 1 436 55 1 409 56 1 361 58 1 318 1 243 1 130 Low 3 1 307 61 1 265 63 1 234 64 1 203 66 1 168 68 1 096 1 0...

Страница 8: ...55 1 396 58 1 321 61 1 253 64 1 182 1 101 986 Low 2 5 1 287 63 1 244 65 1 184 68 1 148 70 1 098 73 1 034 953 849 GCH95 0905DX High 5 2 189 37 2 109 38 2 025 40 1 948 41 1 862 43 1 757 1 644 1 537 Med 4 1 885 43 1 831 44 1 776 45 1 711 47 1 637 49 1 539 1 453 1 346 Med Lo 3 5 1 665 48 1 627 50 1 584 51 1 524 53 1 462 55 1 400 1 323 1 220 Low 3 1 474 55 1 440 65 1 401 57 1 356 59 1 310 61 1 255 1 19...

Страница 9: ...subject to change Always refer to the wiring diagram or the unit for the most up to date wiring W arning High Voltage Disconnect all power before servicing or installing this unit Multiple power sources may be present Failure to do so may cause property damage personal injury or death ...

Страница 10: ...OLARIZED AND GROUNDED BK GND DISCONNECT L N POWER SUPPLY WITH OVERCURRENT PROTECTION DEVICE WH JUNCTION BOX 1 TO 115 VAC 1Ø 60HZ OR ID BLOWER PRESSURE SWITCH HEAT H GND WH RD WH GND BURNER COMPARTMENT BLOWER COMPARTMENT NOTE 4 SEE N O COOL H BK HI BR BR CAPACITOR YL WH YL CONTROL PRIMARY LIMIT AUTO RESET BL PU MANUAL RESET ROLLOUT LIMIT CONTROL S RD OR PK BK WH WH BLOWER INDUCED DRAFT C CIRCULATOR...

Страница 11: ...e Pressure Switch Kit 3 3 3 3 3 3 FTK04 Twinning Kit EFR01 External Filter Rack DCVK 20 Horizontal Vertical Concentric Vent Kit 2 DCVK 30 Horizontal Vertical Concentric Vent Kit 3 0170K00000S Flush mount Vent Kit White Rodgers and Honeywell valves Indicates accessories available for this model 1 Indicates 7 001 to 9 000 altitude 2 Indicates 9 001 to 11 000 altitude 3 Indicates 7 001 to 11 000 alti...

Страница 12: ...it 1 1 1 1 1 1 HANG12 High Altitude Natural Gas Kit 2 2 2 2 2 2 HALP10 High Altitude LP Gas Kit 3 3 3 3 3 3 HAPS27 High Altitude Pressure Switch Kit 3 3 3 3 3 3 EFR01 External Filter Rack DCVK 20 Horizontal Vertical Concentric Vent Kit 2 DCVK 30 Horizontal Vertical Concentric Vent Kit 3 0170K00000S Flush mount Vent Kit White Rodgers and Honeywell valves Indicates accessories available for this mod...