PRODUCT DESIGN

4

If this appliance is installed in
an enclosed area such as a
garage or utility room with any

carbon monoxide (CO) producing appliance (i.e.
automobile, furnace, water-heaters, etc.), ensure
the area is properly ventilated.

WARNING

WARNING

HIGH VOLTAGE

Disconnect ALL power

before servicing or installing this unit.  Mul-
tiple power sources may be present. Failure
to do so may cause property damage, personal
injury or death.

WARNING

WARNING

AIR HANDLERS

See Air Handler Specification Sheet for Proper Combinations.

ALL AIR HANDLERS USE DIRECT DRIVE MOTORS.
POWER SUPPLY IS 208-230 V, 60 HZ, 1 PHASE.

Installation
Before installing this appliance insure that it is properly sized
and adequate power is available.
This appliance can be installed in the vertical or right hori-
zontal position without modification. The horizontal left and
downflow positions require product modification.
This product is designed for zero inches (0 inches) clear-
ance; however, adequate access for service or replacement
must be considered without removing permanent structure.
This unit can be installed on a platform when deemed nec-
essary.
In an attic installation a secondary drain pan must be pro-
vided by the installer and placed under the entire unit with
a separate drain line properly sloped and terminated in an
area visible to the owner. This secondary drain pan is re-
quired in the event that there is a leak or main drain block-
age. Closed cell insulation should be applied to the drain
lines in unconditioned spaces where sweating may occur.
Appliances installed in garages, warehouses or other areas
where they may be subjected to mechanical damage must
be suitably guarded against such damage by installing be-
hind protective barriers, being elevated or located out of
the normal path of vehicles. When installed on a base, the
base must also be protected by similar means.

Heating and cooling equipment located in garages, which
may generate a glow, spark or flame capable of igniting
flammable vapors, must be installed with the ignition source
at least 18"[46cm] above the floor level.
When more than one appliance is installed in a building it
shall be permanently identified as to the area or space ser-
viced by the equipment.
When this product is installed in the downflow installation
in an unconditioned space, remove the horizontal drain pan
and install the following insulation kit.

DFK-B

Downflow Kit

DFK-C

Downflow Kit

DFK-D

Downflow Kit

AVPTC24B14**

AVPTC30C14**

AVPTC42D14**

AVPTC36C14**

AVPTC48D14**

AVPTC48C14**

AVPTC60D14**

MODEL LIST FOR DOWNFLOW KITS

This kit is used to prevent sweating on the vertical drain
pan.

*AVPTC 

is a multi-position, variable-speed air handler and

is used with R-410A. The unit’s blower design includes a
variable-speed ECM motor and is compatible with heat
pumps and variable-capacity cooling applications.

AVPTC air handlers 

are available in 2 to 5 ton sizes with

optional 3 kW to 25kW electric heat kits available for field
installation.  

(See note below.)

NOTE: 

 Factory-sealed to achieve a 2% or less leakage rate

at 1.0" water gauge external duct static pressure.
Complies with the Factory-sealed Air Handling Credit as
listed in the 2001 Florida Building Code, Chapter 13, Section
610.2.A.2.1.

Содержание AVPTC24B14A

Страница 1: ...d on page 3 TECHNICAL MANU TECHNICAL MANU TECHNICAL MANU TECHNICAL MANU TECHNICAL MANUAL AL AL AL AL RT6121004r2 March 2014 Copyright 2013 2014 Goodman Manufacturing Company L P This manual is to be used by qualified professionally trained HVAC technicians only Goodman does not assume any responsibility for property damage or personal injury due to improper service procedures or services performed...

Страница 2: ...cedures If you install or perform service on this unit you assume responsibility for any personal injury or property damage which may result Many jurisdictions require a license to install or service heating and air conditioning equipment WARNING WARNING WARNING WARNING All Airhandlers use DIRECT DRIVE MOTORS Power supply is AC 208 230v 60 hz 1 phase A V P T C 24 B 1 4 A A PRODUCT TYPE A Air Handl...

Страница 3: ...ammable liquids or vapors in the vicinity of this appliance WARNING WARNING When installing or servicing this equipment safety clothing includ ing hand and eye protection is strongly advised If installing this equipment in an area that has special safety requirements hard hats etc ob serve these requirements To protect the unit when braz ing close to the painted surfaces the use of a quenching clo...

Страница 4: ...ed spaces where sweating may occur Appliances installed in garages warehouses or other areas where they may be subjected to mechanical damage must be suitably guarded against such damage by installing be hind protective barriers being elevated or located out of the normal path of vehicles When installed on a base the base must also be protected by similar means Heating and cooling equipment locate...

Страница 5: ...PRODUCT DIMENSIONS 5 AVPTC ...

Страница 6: ...24 000 30 000 36 000 42 000 42 000 48 000 60 000 CFM High range 1100 600 1200 600 1600 700 1660 700 1700 800 1800 1350 2000 1600 Blower Diameter 10 10 10 10 10 10 11 Width 6 8 10 10 10 10 10 Coil Drain Connect FPT Refrigerant Line Connection Size Liquid Suction Electrical Data Voltage 208 240 208 240 208 240 208 240 208 240 208 240 208 240 Electric Heat Capacity kW 3 5 6 8 10 3 5 6 8 10 5 6 8 10 1...

Страница 7: ...tion for details 2 Airflow blink codes are approximations of actual airflow Profiles Pre Run Short Run OFF Delay C OFF ON OFF ON OFF ON C 7 5 min 82 60 sec 100 D 30 sec 50 7 5 min 82 30 sec 50 To Set Comfort mode Select desired Comfort Mode Profile see profiles above Set dip switches S5 and S6 to appropriate ON OFF positions Dehumidification To enable set dip switch S7 to ON Cooling airflow will b...

Страница 8: ...cfm speed tap of ON OFF ON For match up with a 3 5 ton outdoor unit Heater kit application shall not exceed 20 kW Airflow for 5 kW up to 20 kW heater kits shall be set to 1500 cfm speed tap of ON OFF OFF 3 kW heater kit is not applicable for this indoor application Htr kW 9 10 11 AVPTC24B14A AVPTC30C14A AVPTC36C14A AVPTC48C14 AVPTC42D14A AVPTC48D14A AVPTC60D14A 3 ON ON ON 730 730 NR NR 850 NR NR 5...

Страница 9: ...CALL 1 BK 3 M1 W1 RD L2 8 9 R2 HTR2 5 M2 W1 1 M4 BK C L1 8 TWO 2 ELEMENT ROWS RD DEHUM TX 3 BL TWO STAGE INTEGRATED CONTROL MODULE TL 3 GND TL NOTE WHEN INSTALLING HEATER KIT ENSURE SPEED TAP DOES NOT EXCEED MINIMUM BLOWER SPEED MBS SPECIFIED FOR THE AIRHANDLER HEATER HTR2 BL R 6 HEAT SEQUENCER R2 RD TRANSFORMER RD FL YL M7 24 V THERMOSTAT CONNECTIONS 2 HEAT SEQUENCER R1 GN 7 WH TR BK RD FL 2 FL L...

Страница 10: ...IT ENSURE SPEED TAP MUST EXCEED OR EQUAL THE MINIMUM BLOWER SPEED MBS SPECIFIED FOR THE AIRHANDLER HEATER KIT COMBINATION ON THIS UNIT S SERIAL PLATE AFTER INSTALLING OPTIONAL HEAT KIT MARK AN X IN THE PROVIDED BELOW NO MARK INDICATES NO HEAT KIT INSTALLED FIVE 5 ELEMENT ROWS NOTE THIS LABEL MUST BE ATTACHED ON THE AIRHANDLER IN A PROMINENT LOCATION BK RD BK RD 3 Phase Heat Kit 25kW Heat Kit AVPTC...

Отзывы: