PRODUCT DESIGN
4
If this appliance is installed in
an enclosed area such as a
garage or utility room with any
carbon monoxide (CO) producing appliance (i.e.
automobile, furnace, water-heaters, etc.), ensure
the area is properly ventilated.
WARNING
WARNING
HIGH VOLTAGE
Disconnect ALL power
before servicing or installing this unit. Mul-
tiple power sources may be present. Failure
to do so may cause property damage, personal
injury or death.
WARNING
WARNING
AIR HANDLERS
See Air Handler Specification Sheet for Proper Combinations.
ALL AIR HANDLERS USE DIRECT DRIVE MOTORS.
POWER SUPPLY IS 208-230 V, 60 HZ, 1 PHASE.
Installation
Before installing this appliance insure that it is properly sized
and adequate power is available.
This appliance can be installed in the vertical or right hori-
zontal position without modification. The horizontal left and
downflow positions require product modification.
This product is designed for zero inches (0 inches) clear-
ance; however, adequate access for service or replacement
must be considered without removing permanent structure.
This unit can be installed on a platform when deemed nec-
essary.
In an attic installation a secondary drain pan must be pro-
vided by the installer and placed under the entire unit with
a separate drain line properly sloped and terminated in an
area visible to the owner. This secondary drain pan is re-
quired in the event that there is a leak or main drain block-
age. Closed cell insulation should be applied to the drain
lines in unconditioned spaces where sweating may occur.
Appliances installed in garages, warehouses or other areas
where they may be subjected to mechanical damage must
be suitably guarded against such damage by installing be-
hind protective barriers, being elevated or located out of
the normal path of vehicles. When installed on a base, the
base must also be protected by similar means.
Heating and cooling equipment located in garages, which
may generate a glow, spark or flame capable of igniting
flammable vapors, must be installed with the ignition source
at least 18"[46cm] above the floor level.
When more than one appliance is installed in a building it
shall be permanently identified as to the area or space ser-
viced by the equipment.
When this product is installed in the downflow installation
in an unconditioned space, remove the horizontal drain pan
and install the following insulation kit.
DFK-B
Downflow Kit
DFK-C
Downflow Kit
DFK-D
Downflow Kit
AVPTC24B14**
AVPTC30C14**
AVPTC42D14**
AVPTC36C14**
AVPTC48D14**
AVPTC48C14**
AVPTC60D14**
MODEL LIST FOR DOWNFLOW KITS
This kit is used to prevent sweating on the vertical drain
pan.
*AVPTC
is a multi-position, variable-speed air handler and
is used with R-410A. The unit’s blower design includes a
variable-speed ECM motor and is compatible with heat
pumps and variable-capacity cooling applications.
AVPTC air handlers
are available in 2 to 5 ton sizes with
optional 3 kW to 25kW electric heat kits available for field
installation.
(See note below.)
NOTE:
Factory-sealed to achieve a 2% or less leakage rate
at 1.0" water gauge external duct static pressure.
Complies with the Factory-sealed Air Handling Credit as
listed in the 2001 Florida Building Code, Chapter 13, Section
610.2.A.2.1.