4
MONITOR SETTINGS
Golmar se reserva el derecho a cualquier modificación sin previo aviso.
Golmar se réserve le droit de toute modification sans préavis .
Golmar reserves the right to make any modifications without prior notice.
www.golmar.es
Sistemas de comunicación S.A.
EN
TEKNA-S
TWIN MONITOR
G
QUICK GUIDE
EL60 D
6
C. 00
EL632/GTWIN
C. 02
C. 04
C. 06
C. 05
C. 03
C. 01
1
8
2 3 4 5 6 7
ON
C. 08
C. 10
C. 09
C. 07
1
2 3
ON
4 5 6
C.126
7 8
1
2 3
ON
4 5 6 7 8
1
2 3
ON
4 5 6 7 8
1
2 3
ON
4 5 6 7 8
1
2 3
ON
4 5 6 7 8
1
2 3
ON
4 5 6 7 8
1
2 3
ON
4 5 6 7 8
1
2 3
ON
4 5 6 7 8
1
2 3
ON
4 5 6 7 8
1
2 3
ON
4 5 6 7 8
1
2 3
ON
4 5 6 7 8
1
2 3
ON
4 5 6 7 8
EL610D
1 2
4 5 6 7
3
8
ON
C. 12
C. 14
C. 16
C. 18
C. 20
C. 1
1
C. 19
C. 17
C. 15
C. 13
1
2 3
ON
4 5 6 7 8
1
2 3
ON
4 5 6 7 8
1
2 3
ON
4 5 6 7 8
1
2 3
ON
4 5 6 7 8
1
2 3
ON
4 5 6 7 8
1
2 3
ON
4 5 6 7 8
1
2 3
ON
4 5 6 7 8
1
2 3
ON
4 5 6 7 8
1
2 3
ON
4 5 6 7 8
1
2 3
ON
4 5 6 7 8
*
( )
2
( )
1
( )
3
( )
Remember:
Button panel up to 122 apartments.
One building with 1 column of up to 127 monitors and 1 main video door panel (buttons).
WIRING DIAGRAM
CO UMN
L
EN
FA-GTWIN
Main panel
2
( )
PA
SP
SE+
SE-
SE2
LINE
LINE 1
LINE 2
230
0
3
( )
POWER SUPPLY
Exterior door release
button.
NC ontact =
c
Door closed
Lock release
m x. 12 V c/270mA.
a
d
To connect the secondary AC lock release
(Golmar), see the
“
TGTWIN SYSTEM
MANUAL
”
page 45.
To configure the SAV-GTWIN call repeater,
see the TTEKNA
GTWIN manual, p. 18.
S
To connect the FA-Gtwin power supply to
the filter and line protector, see the
TGTWIN SYSTEM MANUAL, p. 44.
Remove the jumper from all of the
distributors except the last.
Important:
-For further information about the door panel,
sections, distances, wiring diagrams, etc., (see
the
GTWIN SYSTEM MANUAL
cód.
“
T
”
50122345).
https://doc.golmar.es/search/manual/50122345
*
( )
Factory default.
=
=
ON
ON
ON
OFF
=
=
ON
ON
ON
OFF
SW1 configuration switch:
DIP switch 1:
Must be OFF.
DIP switches 2 to 8:
To configure the desired code (2 = most significant bit and 8 = least significant bit).
Below is an example of a site with 22 apartments:
SW2
SW1
1 2 3 4 5 6 7 8
1 2
*
( )
INT:
Define the internal code of the monitor/telephone in order to set it as master, slave 1, slave 2 or slave
3 using the SW2 switch with a code from 0 to 3 respectively.
2
1
INT 1
ON
2
1
INT 0
ON
2
1
INT 2
ON
2
1
INT 3
ON
*
( )
Factory default.
*
( )
SW2 configuration switch:
Co
Monitor
de
/ Telephone
*
( )
Co
Monitor
de
/ Telephone
Co
Monitor
de
/ Telephone
Co
Monitor
de
/ Telephone
TO THE FOLLOWING DISTRIBUTORS
Z=ON
*
( )
Z=OFF
D4L-GTWIN
DISTRIBUTOR
Apartment
front door
call.
+S
-S
SAV-GTWIN
call
repeater
1
( )
LINE IN
LINE OUT
CP
S+
S-
LINE OUT
LINE
3
LINE
4
LINE
1
LINE
2
LINE IN
S+
S-
LINE IN
LINE OUT
CP
LINE IN
LINE OUT
CP
S+
S-
LINE IN
LINE OUT
CP
S+
S-
S+
S-
LINE IN
LINE OUT
CP
S+
S-
LINE IN
LINE OUT
CP
LINE OUT
LINE
3
LINE
4
LINE
1
LINE
2
LINE IN
LINE IN
LINE OUT
CP
S+
S-
S+
S-
LINE IN
LINE OUT
CP
Video door
entry system
Apartment
front door
call.
Apartment
front door
call.
Apartment
front door
call.
Apartment
front door
call.
Apartment
front door
call.
Apartment
front door
call.
Apartment
front door
call.
D4L-GTWIN
DISTRIBUTOR
50124297
TTEKNA
GTWIN E
S
N GR
REV.0122
MONITOR
MASTER
2
1
INT 0
ON
SW2
J2
F. Line
ON (Z)
MONITOR
MASTER
2
1
INT 0
ON
SW2
J2
F. Line
ON (Z)
MONITOR
MASTER
2
1
INT 0
ON
SW2
J2
F. Line
ON (Z)
MONITOR
MASTER
2
1
INT 0
ON
SW2
J2
F. Line
ON (Z)
MONITOR
MASTER
2
1
INT 0
ON
SW2
J2
F. Line
ON (Z)
MONITOR
MASTER
2
1
INT 0
ON
SW2
J2
F. Line
ON (Z)
MONITOR
MASTER
2
1
INT 0
ON
SW2
J2
F. Line
ON (Z)
MONITOR
MASTER
2
1
INT 0
ON
SW2
J2
F. Line
ON (Z)
IMPORTANT:
For optional programming,connections and more information,see "TTEKNA-S GTWIN" manual.