33
Lock release connection
Relay output auxiliary device connection
The drawing shows the connection of a 12Vd.c. lock release, with a maximum consumption of 270mA. The use of
the Golmar CV-14 / DC, CV-24 / DC, CV-14P / UNI or CV-24P / UNI models is recommended. Activation is
done through the
icon.
The activation time is 3 seconds, it being possible to adjust it between 0.5 and 10 seconds (see page 36).
1
The drawing shows, as an example, the connection of a second AC lock release. The relay can switch loads of 6A /
24V. Activation is done through the
icon.
The activation time is 3 seconds, it being possible to adjust it between 0.5 and 10 seconds (see page 36).
2
If the lock release you are going to use is AC, use a relay and a transformer suitable for consumption. The example
shows a Golmar SAR-12/24 relay and a TF-104 transformer (12Va.c./1.5A).
CV-
BUS
CV+ AP+
BUS
CV-
BUS
CV+ AP+
BUS
IN
IN
C
NC
NA
CA
UT
IO
N
PRI
PRI
Mains
100~240Vac
SEC
SEC
GND
C
CCTV AP-
NA
CA
UT
IO
N
PRI
PRI
Mains
100~240Vac
SEC
SEC
SOUL S5110/ART 7W VIDEO INTERCOM KIT
INSTALLATION DIAGRAMS