- This operating mode allows activation of the stairs light from the apartment.
(
:
Dip 4
ON
Light operating mode Set the
to
and from the
to
to
i the configuration
switch of the
Dip1
Dip3
OFF n
SW1 dip
SAR-G2+).
It will be activated by pressing the button located below the light con
on the screen in the settings menu
i
displayed
of the ART 4 / ART 4 LITE monitor, in the main menu of the ART 7 / ART 7 LITE monitor by clicking on the icon of the
,
ART 7W monitor displayed on the screen in the main menu
for 3 seconds
or pressing the
......
ART 1
button
of the
terminal
.
or T-ART telephone (in standby and handset on the hook on T-ART telephone)
- See user manual for monitor
installed in the apartment.
or terminal
OPERATING MODES
Stairs light activation relay (necessary module SAR-12/24):
Access
panel
door
G2+
Mains
100~240Vac
FA-G2+
SAR-G2+
SAR-12/24
Bus Monitors
2
To stairs light
push button
*
( )
Neutral point of the power supply of the stairs light is connected in series through the relay contacts of the SAR-12/24.
IMPORTANT:
For the description, installation, configuration and programming of the system, see the corresponding manual.
2
- This operating mode allows activation of a Golmar additional alternating lock release. This lock release is activated as lock
release 1 or lock release 2 and with the panel that has been assigned (through configuration in SAR-G2
see
) during
+,
page 4
a call or communication process.
of corresponding icon
or
(
It will be activated by pressing the button located below
lock release 1 or lock release 2
respectively) shown on the
ART4 LITE/
/ ART7 LITE monitor screen,
corresponding
ART4/
ART7
by clicking on the
icon of the
ART 7W monitor displayed on the screen o
or
terminal or T-ART telephone.
r pressing the
ART 1
button
of the
- See user manual for
installed in the apartment
monitor/ audio terminal
.
Additional lock release activation relay (necessary power supply unit TF-104):
Access
panel
door
G2+
Mains
100~240Vac
FA- 2+
G
SAR-G2+
TF-104
Bus Monitors
2
Additional Vac
lock release
*
( )
2
TF-104
Mains
100~240Vac
2
*
( )
The power supply of the lock release is connected in series through the SAR-G2 relay contacts.
+
IMPORTANT:
For the description, installation, configuration and programming of the system, see the corresponding manual.
2
2
2
2
2
2
2
RELAY UNIT TSAR-G2+
220Vca/ 1.8A máx.
*
( )
ON
1
2
3
4
SAR-G2+ configuration SW1 dip switch:
Light operating mode:
Dip 4
ON.
to
Dip 1
Dip3 a OFF.
to
JP1 jumper:
Leave in the pos. 2-3.
1
2
Important:
-If the door panel has the lock release 1 connected, lock release 2
must be connected to the SAR-G2+ relay unit.
-If the door panel has the lock releas 2 connected, lock release 1
must be connected to the SAR-G2+ relay unit.
Do not repeat the same lock release on both the panel and
the SAR-G2+ relay unit.
JP1 jumper:
Leave in the pos. 2-3.