background image

3

50123708  DS551209-002A

ENGLISH

The timer 12091022 SAR-12/24T allows to operate on different kinds of electronic locks:

• 

direct activation by means of capacitive discharge

• 

activation with capacitive discharge and 150 mA stop current

• 

security electronic locks

INSTALLATION

It may be mounted on DIN bar or by wall surface by means of 2 screws and spacers (to be bought separarately). 

DESCRIPTION OF TERMINALS

 +24  voltage input 22÷27 Vdc

 +12 ~  voltage input 10÷15 Vdc or 10÷15 Vac

 -/~    common wire

 -/~    common wire

 SE2   timer adjust input; its activation is possible by connecting it to the voltage common wire

 AP 

door release output

 NO 

normally this contact is open

 NC 

normally this contact is closed

 C 

this one is common for NC/NO, it is normally connected to the voltage common wire (-/~)

JUMPERS AND ARRANGEMENTS

• 

AR: possibility of recycle

During the operation with jumper AR in position “NO” , the timer will 

activate the relay output in presence of the external adjust “SE2” 

and for the programmed time only. The input signal is not a decisive 

factor. During the operation with the jumper AR in position “SI” , the 

timer will activate the relay output min. for the programmed time; if 

the input signal “SE2” should last over the programmed time, the 

output will keep active.

• 

AMCR: possibility of connecting the common wire of the relay

By default C and -/~ terminal pins are connected each other; if the 

jumper is cut, they are separated.

• 

TIME: potentiometer for programming the delay of the activation of 

the  output  relay;  the  max.  delay  may  be  obtained  by  turning  the 

potentiometer clockwise.

DISPLAY

LED LI on: input SE2 is active

LED LO on: the relay output is active

TECHNICAL FEATURES

Voltage on + 24: ..............................................................................................................................

22÷27 Vdc

Voltage on +12  ~: ......................................................................................................................

10÷15 Vdc/ac

Continuous current from AP: ........................................................................................................

125÷170 mA

Timing range:...............................................................................................................................

1÷30 s ±20%

Functioning temperature:................................................................................................................

-10÷+45 °C

Max. resistive commutable charge: .....................................................

10 A with 24 Vdc / 10 A with 120 Vac

Max. voltage for switching: .................................................................................................

240 Vac / 110 Vdc

Max. resistive commutable power: ...........................................

1400 VA with 240 Vac / 300 W with 110 Vdc

Min. charge to apply: ...........................................................................................................

10 mA with 5 Vdc

Maximum load at 12 Vdc: .....................................................................................................................

200 mA

Dimensions (l x h x w):  ...................................................

72 (4 DIN modules, each of 18mm) x 75 x 90 mm

SE2 input activation time

configured activation time (TIME)

contact switching time

AR = NO

SE2 input activation time

configured activation time (TIME)

contact switching time

AR = SI

Содержание SAR-12/24T

Страница 1: ...Mod GTwin 50123708 DS551209 002A TEMPORIZZATORE PER ELETTROSERRATURA MULTIUSO LOCK RELEASE TIMER TEMPORISATEUR OUVRE PORTE UNIDAD RELE SAR 12 24T TEMPORIZADO SCHLO FFNUNGSZEITSCHALTER Ref 12091022 SA...

Страница 2: ...l timer attiver l uscita a rel come minimo per il tempo impostato se il segnale d ingresso SE2 dovesse perdurare oltre il tempo impostato l uscita continuer a rimanere attiva AMCR Abilitazione massa c...

Страница 3: ...peration with the jumper AR in position SI the timer will activate the relay output min for the programmed time if the input signal SE2 should last over the programmed time the output will keep active...

Страница 4: ...sateur activera la sortie relais min pour le temps programm si le signal d entr e SE2 persiste apr s le temps programm la sortie relais sera active AMCR branchement avec le fil commun du relais En usi...

Страница 5: ...aci n AR en posici n SI el temporizador activar la salida a rel como m nimo para el tiempo programado si la se al de ingreso SE2 estuviera todav a activa m s del tiempo programado la salida se quedar...

Страница 6: ...ngig von der Eingangssignaldauer Wenn sich die Br cke w hrend des Betriebs auf Stellung SI befindet wird der Relaisausgang durch den Zeitschalter f r die mindeste eingestellte Zeit aktiviert wenn das...

Страница 7: ...ecchiature ad un filtro e a un dispositivo di protezione per la linea d alimentazione Connect the devices to a filter and power line protection device Connecter les appareils un filtre et un dispositi...

Страница 8: ...du 4 juillet 2012 relatif aux d chets d quipements lectriques et lectroniques DEEE Le symbole de la poubelle sur roues barr e d une croix pr sent sur le produit ou sur son emballage indique que ce pr...

Отзывы: