CODIGO / CODE
MASTER SLAVE
INTER
A1
ATENCIÓN
Alta tensión. No abrir la tapa.
Manipular sólo por personal
del servicio técnico.
WARNING
High voltage. Don't open cover.
Handle only by technical service.
PLATEA UNO
REF.
11784022
COD.
PUERTA
Door
ESCALERA
Stair
PISO
Floor
VERSIÓN
Nº SERIE
00000000000
X.XX
DOORPANEL CONFIGURATION
46
oorpanel configuration.
D
The doorpanel is provided with microswitches (SW1) and
a jumper (JP1) in its rear part; Their functions are
described below.
When this switch is ON, the doorpanel can autoswitch-on (audio
and/or video communication without any call). In buildings
with several doorpanels, just activate this function in one of
them. In systems equipped with a general doorpanel, this
function can be activated in one doorpanel of each detached
house.
Select ON to set up monitors and phones.
At the end of program, select OFF again.
Page 49 describes monitor program method; while page 51
decribes phone program method.
Select OFF in case of a main doorpanel. Each system must be
equipped with just one main doorpanel; all the others must be
slave doorpanels (ON). In systems provided with a general
doorpanel, one doorpanel of each house will be configured as
main doorpanel.
Select OFF if the doorpanel is provided with a camera. Select
ON if it has no camera.
With a general
select ON to set up the installation
line
doorpanel,
; at the end of program, select OFF again.
Page 52 describes the program method.
Equip the installation with a
To ensure
a correct operation, this resistance must be activated only in
the
which is the nearest to the installation line
,
communication resistance.
doorpanel
or in
the main doorpanel (if one exists). If any RD-Plus/Uno repeater
is used it must be deactivated in the doorpanels behind it.
*Factory value
1
2
3
1
2
3
It allows the connection of an alternative current
door opener; page 57 shows the connection
diagram.
It allows the connection of a direct current door
opener; page 57 shows the connection
diagram.
SW1
JP1
45
MONITOR DESCRIPTION
latea Uno monitor description.
P
a
g
h
b
f
l
k
m
e
j
i
a.
b.
c.
d.
e.
f .
g.
h.
i .
j .
k.
l .
M.
Handset.
B/w or color display (depending on the model).
Unavailable buttons.
Starting pilot light.
Function buttons.
Phone cord.
connector fixing devices.
Identification label.
Terminal block connection points.
CN2 connector.
Phone cord connector.
Contrast adjustment (color adjustment in color
monitors)
Brightness adjustment.
c
d
When the handset is hung up, it allows the user to see the image coming from the main
doorpanel. When the handset is lifted, it allows to establish an audio/video
communication with the doorpanel in which the autoswitch-on function is activated.
It does not work during a communication.
When the handset is hung up, keep this button pressed during 1 second to turn the
monitor on or off. During the 45 seconds after the monitor has been turned on,
it will only be able to receive calls. When the handset is lifted, it allows the
user to call the main porters exchange. When a call is received or during
communication, it enables the door opener.
unction buttons.