30
WIRING DIAGRAMS
(
)
BLOCK MODE
:
Audio door entry system with
block mode
generals coded door panels, 4 buildings, 128 audio terminals per building, 4 RD-G2+
“
”
.
Mains
100~240Vac
BUS (M) BUS(PL)
FA-G2+
L
N
Mains
100~240Vac
BUS (M) BUS(PL)
FA-G2+
L
N
Technical room
Technical room
Mains
100~240Vac
BUS (M) BUS(PL)
FA-G2+
L
N
Technical room
OUT
IN
RD-G2+ (4)
FA
PL
Mains
100~240Vac
BUS (M) BUS(PL)
FA-G2+
L
N
Technical room
Only audio installation,
configur the end of
e
line
n
i
Dip 10
OFF
.
to
all audio terminals
Configur the end of line in
e
the last
.
RD-G2+
Dip 8 to On.
**
( )
*
( )
Note:
, see a e
p g 7.
Distanc s
e and cross-sections
( )
2 Important: Make the connections in electrical junction box.
APARTMENT 1
APARTMENT 2
*
( )
1 ( )
APARTMENT 127
APARTMENT 128
Building 4
AUX
BUS
AUX
BUS
AUX
BUS
AUX
BUS
ON
1
2
3
4
5
6
7
8
9
10
ON
1
2
3
4
5
6
7
8
9
10
ON
1
2
3
4
5
6
7
8
9
10
ON
1
2
3
4
5
6
7
8
9
10
APARTMENT 1
APARTMENT 2
APARTMENT 127
APARTMENT 128
Building 3
AUX
BUS
AUX
BUS
AUX
BUS
AUX
BUS
ON
1
2
3
4
5
6
7
8
9
10
ON
1
2
3
4
5
6
7
8
9
10
ON
1
2
3
4
5
6
7
8
9
10
ON
1
2
3
4
5
6
7
8
9
10
APARTMENT 1
APARTMENT 2
APARTMENT 127
APARTMENT 128
Building 2
AUX
BUS
AUX
BUS
AUX
BUS
AUX
BUS
ON
1
2
3
4
5
6
7
8
9
10
ON
1
2
3
4
5
6
7
8
9
10
ON
1
2
3
4
5
6
7
8
9
10
ON
1
2
3
4
5
6
7
8
9
10
APARTMENT 1
APARTMENT 2
APARTMENT 127
APARTMENT 128
Building 1
AUX
BUS
AUX
BUS
AUX
BUS
AUX
BUS
ON
1
2
3
4
5
6
7
8
9
10
ON
1
2
3
4
5
6
7
8
9
10
ON
1
2
3
4
5
6
7
8
9
10
ON
1
2
3
4
5
6
7
8
9
10
1
2
3
ON
DIP
4
5
6
7
8
**
( )
OUT
IN
RD-G2+ (2)
FA
PL
1
2
3
ON
DIP
4
5
6
7
8
**
( )
OUT
IN
RD-G2+ (1)
FA
PL
1
2
3
ON
DIP
4
5
6
7
8
**
( )
OUT
IN
RD-G2+ ( )
3
FA
PL
Block mode
Block mode
Block mode
BUILDING 1
BUILDING 2
BUILDING 3
Interior door panels (see page 36-38).
Interior door panels (see page 36-38).
Interior door panels
(see page
-38).
36
1
2
3
ON
DIP
4
5
6
7
8
**
( )
Block mode
BUILDING 4
Interior door panels
(see page
-38).
36
*
( )
1 ( )
*
( )
1 ( )
*
( )
1 ( )
*
( )
1 ( )
*
( )
1 ( )
*
( )
1 ( )
*
( )
1 ( )
*
( )
1 ( )
*
( )
1 ( )
*
( )
1 ( )
*
( )
1 ( )
( )
2
( )
2
( )
2
( )
2
( )
1 Important:
For description, installation, configuration and programming of door panels and
, see the corresponding manuals.
audio terminals
ART 1 / T-ART
Master
ART 1 / T-ART
Master
ART 1 / T-ART
Master
ART 1 / T-ART
Master
ART 1 / T-ART
Master
ART 1 / T-ART
Master
ART 1 / T-ART
Master
ART 1 / T-ART
Master
ART 1 / T-ART
Master
ART 1 / T-ART
Master
ART 1 / T-ART
Master
ART 1 / T-ART
Master
ART 1 / T-ART
Master
ART 1 / T-ART
Master
ART 1 / T-ART
Master
ART 1 / T-ART
Master
*
( )
1 ( )
*
( )
1 ( )
*
( )
1 ( )
*
( )
1 ( )
*
( )
1 ( )
RD-G2
+
DIGIT
AL REPEA
TER
To "Bus M" of the FA-G2+ power supply (see page 36).
Note: More than 1 door panel (see page 37 and 38).