background image

90CS

CEA90C

99

143

40

Door panel

Model

An

Al

P

90C

CEV90C

99

250

56

90

CEV90

99 mm.

328 mm.

56 mm.

1650

1850

1450

79

DOOR PANEL INSTALLATION

DOOR PANEL INSTALLATION

E

mbedding box positioning.

The upper part of the door panel should be placed at 1,65m. height roughly. The hole dimensions

will depend on the type of door panel.

The door panel has been designed to be placed under most of the environmental conditions.

However it's recommended to take additional cautions like rainproof covers. To obtain a good
quality picture on video door entry systems, avoid direct incidence from light sources.

P

reparing the cables entry.

Break the bottom flange

to pass the cables through. In case of door panels

with more than one embedding box, break the side flanges and
attach the embedding boxes using UC junctions.

A

ssembly the electronic modules.

Insert the sound module in the top part of the module frame.

Align the tabs on the sound module in their respective housings of the module frame and
later exercise a light pressure until correct placement.

Sound module

EL632 Plus P/T
EL642 Plus

Push buttons electronic

module EL610D

Frame

If there is push buttons module repeat the above process, locating under the sound module,

as shown in the drawing.

Frame

80

P

lace the embedding box.

Pass the wiring through the hole made in the bottom part of the

embedding box. Level and flush the embedding box. Once
the embedding box is placed, remove the protective labels
from the attaching door panel holes.

Содержание Plus Nexa

Страница 1: ...Plus Nexa Code 50122328 Instructions manual Audio and Video door entry system One or several accesses doors General door panel T632 PLUS N P T E rev 0118...

Страница 2: ...e Golmar RAP 5130 In installations no longers than 100m cable can be used Introduction 73 Index 73 Starting recommendations 73 Safety precautions 74 System characteristics 74 Important notice 75 Syste...

Страница 3: ...l 50123594 O Telephone T540 Plus SE Description installation configuration and programming of the telephone see manual T540 PLUS SE C d 50122199 disponible en https doc golmar es search manual 5012219...

Страница 4: ...ls are not in use if the visitor tries to make a call to a busy inner door panel an acoustic tone will be heard confirming the system is busy and the general door panel will blink for 3 seconds led O...

Страница 5: ...es Embedding boxes Push buttons module Main module Door panel description For the connection of the push buttons between the sound module and the push buttons module EL610D and between push buttons mo...

Страница 6: ...Audio input communication Twisted pair video signal input Twisted pair video signal output Coaxial shield Video signal coaxial input Video signal coaxial output Color camera only EL632 PLUS module P...

Страница 7: ...ons electronic module EL610D description Front side Push buttons module x10 Configuration dip switch Push buttons call code Push button number Input Output push buttons connector x3 Back side MODULES...

Страница 8: ...door panel The door panel has been designed to be placed under most of the environmental conditions However it s recommended to take additional cautions like rainproof covers To obtain a good quality...

Страница 9: ...placement Sound module EL632 Plus P T EL642 Plus Push buttons electronic module EL610D Frame If there is push buttons module repeat the above process locating under the sound module as shown in the d...

Страница 10: ...tons EL610D module as shown in the drawing Between push buttons modules EL610D of different embeddingt boxes insert the short connection cable in the low connector of the last module EL610D of the fir...

Страница 11: ...Off Off On Off Off Off Off On On On On On On On Off Off Off Off Off On Off Off Off Off Off Off Off On Off Off On Off Off Off Off Off Off Off On Off Off On Off Off Off Off Off Off Off Off Off Off Off O...

Страница 12: ...d to the system with control manu l a TCode C Nexa A NFC EL3002 Con ect M xim 2 n to power the illumination module a um EL3002 modules CD NEXA BT Con ect n to the module to add to the system with a co...

Страница 13: ...led will turn on during the call time process During communication The led will turn on during communication process During door release The led will turn on during door release End of communication T...

Страница 14: ...panel if exists set the rest to OFF Set to ON so that the volume tone emitted by the door panel call reception busy system and lock release are or placed to OFF if a HIGH LOW volume tone is desired U...

Страница 15: ...monitor telephone manual see page 74 for manual web link In general door panel EL501 mode set to ON for general door panel push buttons programming or backbone building monitor telephones The program...

Страница 16: ...lly programmed Repeat these steps to program the rest of push buttons Once the programming has been finished set to OFF the programming switch If you don t the general door panel will reproduce a tone...

Страница 17: ...t the switch 2 to ON to show that the system is ready for programming the general door panel will reproduce a tone Press the general door panel push button that is wished has this monitor telephone co...

Страница 18: ...step Programming the monitors and telephones from a general door panel Description of the function connector CN3 The function connector Cn3 is located at the upper left side of the back of the sound m...

Страница 19: ...iring configuration and final adjustments fix the frame in the embedding box with the supplied screws Close the frame If after starting the system it s considered that the audio volume isn t correct p...

Страница 20: ...echanical assembly for double door panel and once finished the adjustments stick the adhesive gasket that is supplied with the push buttons module in the rod of joining modules If the door panel to in...

Страница 21: ...at can be connected to a FA Plus C power supply is 10 and 50 units in case of a FA Plus model Link power supplies to connect more units than the specified as it s shown on page 105 If the lock release...

Страница 22: ...1 D2 D2 D4L PLUS D4L PLUS JP1 JP1 S S M D Malla Vin Ain Aout Vin Vout Vout CN1 CV1 CV2 10 1 9 2 8 3 7 4 6 5 CN3 Main Place this power supply as closest as possible to the first distributor Take off JP...

Страница 23: ...Copper core Copper shield ELECTRICAL CHARACTERISTICS Nominal capacitance Characteristic impedance VALUES Velocity of Propogation Access door panel The installation diagram shows the connection of a vi...

Страница 24: ...T Vpi Vd1 Mpi Md1 _ _ A D CT Vd6 Md6 _ A D Vpo Mpo _ D6L Plus 2H Vp Mp A D _ EL562 JP1 Vp Mp A D _ EL562 JP1 D Malla Vin Ain Aout Vin Vout Vout CN1 CV1 CV2 10 1 9 2 8 3 7 4 6 5 CN3 Place this power su...

Страница 25: ...video system with one or several door panels for the same building If the system has one access door panel only override the wiring to the second door panel If the system has more than one access doo...

Страница 26: ...a Vin Ain Aout Vin Vout Vout CN1 CV1 CV2 10 1 9 2 8 3 7 4 6 5 CN3 Main Place this power supply as closest as possible to the first telephone Access door panel M Master S Slave Lock release Vd c A _ D...

Страница 27: ...out CV1 CV2 Lock release Vd c Access door panel The installation diagram shows the connection of an audio system with one or several door panels for the same building If the system has one access doo...

Страница 28: ...ter S Slave BACKBONE 0 E S S1 D4L PLUS JP1 FA Plus o FA Plus C SEC PRI FA Plus C SEC PRI 230 110 0 M D Malla Vin Ain Aout Vin Vout Vout CN1 CV1 CV2 D Malla Vin Ain Aout Vin Vout Vout CN1 CV1 CV2 Lock...

Страница 29: ...door panel GENERAL DOOR PANEL BACKBONE 0 E S S1 D4L PLUS JP1 SEC PRI FA Plus o FA Plus C FA Plus C SEC PRI 230 110 0 M D Malla Vin Ain Aout Vin Vout Vout CN1 CV1 CV2 D Malla Vin Ain Aout Vin Vout Vout...

Страница 30: ...s and up to 120 inner door panels backbones buildings In case of more than two door panels wire them as the second is conected In video systems use a D4L Plus distributor before each inner building ex...

Страница 31: ...ct our technical support department 1 50mm 2 50mm 0 25mm 0 25mm CAT 5 RG 59 Terminal SECTIONS CHART 100m Distance 300m A A A D in out V V in out V V V V in in out out CV1 CV2 RG 59 CAT 5 Coaxial Sw1 3...

Страница 32: ...out Vin Vout Vout CN1 CV1 CV2 D Malla Vin Ain Aout Vin Vout Vout CN1 CV1 CV2 To telephones Main Main General door panel Inner door panel BACKBONE 1 EL501 mode EL500 mode BACKBONE 0 M Master S Slave 10...

Страница 33: ...ontact our technical support department CV1 CV2 Main IMPORTANT NOTES To install and configure properly do always follow the enclosed information The installation diagram shows the connection of an aud...

Страница 34: ...equired quantity The first power supply should be connected to the door panel and to the first group of monitors or telephones connect the next groups to the positive terminal of its corresponding pow...

Страница 35: ...ws to exit from the building being not necessary the use of a key Door panel Lock release Vd c Main To monitors Main Connection to the synthese vocale module of FDI for France Lock release Vd c 106 OP...

Страница 36: ...ion progresses w The CV1 and CV2 terminals for door opening are voltage free outputs The cable requires a connection depending on whether 12Vdc or 12Vac is needed page to page 105 93 104 w Make a shor...

Страница 37: ...108 NOTAS NOTES...

Страница 38: ...NOTAS NOTES 109...

Страница 39: ...110 NOTAS NOTES...

Страница 40: ...e provocar interferencias da inas y 2 debe aceptar cualquier interferencia recibida incluyendo las que pueden provocar un funcionamiento no deseado NOTE Operation is subject to the following condition...

Отзывы: