91
DOOR PANEL INSTALLATION
C
lose the door panel.
D
oor panel assembly.
In assemblies of a single door panel, it is ready from factory
to be mounted.
IMPORTANT:
To make these adjustments of joining several door panels, see the
document that is supplied with the door panel and follow the
steps that are described in the section" Mechanical assembly
for double door panel" and once finished the adjustments stick
the adhesive gasket (that is supplied with the push buttons
module) in the rod of joining modules.
If the door panel to installing is of more than one module it will be
necessary make some adjustments to join a door panel with
other one.
Fix the door panel by using the supplied screws.
Finish the door panel assembly by placing the closing
heads, put the head on one side and then make a slight
pressure on the other end, to its correct placement.
92
LOCK RELEASE INSTALLATION
I
nstalling the FA-PLUS and FA-PLUS/C power supplies.
DIN 46277
3,5 x 25
DIN-7971
3,5 x 25
DIN-7971
POWER SUPPLY INSTALLATION
L
ock release installation.
Replace the protection cover once the input terminals have been wired.
It's recommended to protect the power supply by using a
thermo-magnetic circuit breaker. Use a ground
connection with FA-Plus power supply.
To install the power supply directly on the wall, drill two holes of
Ø6mm. and insert the wallplugs. Fix the transformer with the
specified screws.
The power supply can be installed on a DIN 46277
guide simply pressing it.
To disassemble the power supply from the DIN guide,
use a plain screwdriver to lever the flange as shown
on the picture.
The FA-Plus/C model uses 6 units over DIN guide and
10 units the FA-Plus model.
IMPORTANT: the maximum number of units that can be connected to a FA-Plus/C power supply is
10, and 50 units in case of a FA-Plus model. Link power supplies to connect more
units than the specified as it's shown on page 105.
If the lock release will be installed in a metal door, use a
Ø3,5mm.
drill and tap the hole
Ø3mm. drill
. In case of wood door, use a
.
Install the power supply in a dry and protected place without risk of drip or water projections.
To avoid an electrical shock, neither remove the primary protection cover nor handle the connected
wire in the terminals.
The installation and handling of these equipments must be performed by authorised personnel and
without the power connected.
To avoid damage, the power supply has to be firmly fixed.
IMPORTANT:
- The lock relese must be of (Golmar)
d.c or a.c
12V
.
(
05
93
See page 1
(a.c lock release) and pages
to 1
(d.c lock release
04
).
- A varistor is supplied with the sound module. In case to connect an a.c. lock release, place the
varistor on the lock release terminals directly to ensure a proper system operation.
M 4 x 8
3,5 x 25
DIN-7972