FA-G2+ POWER SUPPLY INSTRUCTIONS

1. Introduction:

2. Terminal description:

4.  Wiring:

Open the AC protection cover:

1.  Remove the protection cover

fixing screw

 
 

2. Push up the protection cover.

5. Specification:

 

Input Voltage:
Input Frequency:
Rated Output Voltage:
Rated Output Current:
Working Temperature:
Dimensions:

  

100~240Vac
50~60 Hz
30 Vdc 

±

 2V

5A

1,
-10ºC ~ 40ºC
140*90*60mm

3. Installation:

1: Mount the din rail to the wall with wallplugs and screws that
    are suplied with power supply.

 

2: Place the power supply simply pressing it.

 

 

 

LED:  Power indicator, always on when plug in power.

BUS(M):  Monitor connection bus terminal.

BUS(PL):  Door panel connection bus terminal.

Note: 

The installation and handling of this equipment must be

    performed by authorised personnel and without the power
    connected.

6. Warning:

Golmar reserves the right to make any modifications without prior notice.

Din rail.

DIN rail latch release.

BUS(M)

Connect to monitor

Connect to door panel

BUS(PL)

FA-G2+ power supply has been exclusively designed to be used 
on Golmar G2+ video door entry. Golmar will not be responsible of 
the possible damages caused for an improper use or when used 
for other purposes than the specified.

Features:
- Universal AC input/full range.
- Multi protection: Short circuit and overload.
- Integrated with Bus splitter (monitor/ door panel).
- Additional Bus splitter (monitor/ door panel) is not needed.
- DIN 46277 rail mounting.

3. Next pull it out.

-This device has been exclusively designed to be used on Golmar 

G2+ video door entry system. Golmar will not be responsible of the 
possible damages caused for an improper use or when used for 
other purposes than the specified.

-The installation and handling of this equipment must be performed 

by authorised personnel and without the power connected.

-Install the power supply in a dry and protected place with enough 

ventilation, without risk of drip or water projections.

-Install the power supply according to your country rules.
-Do  not  use  excesive  force  when  tightenning  the  power  supply 

connector screws.

-The device must be protected by using a thermo-magnetic circuit 

breaker.

-The  power  supply  must  be  unplugged  from  mains  during 

installation or maintenance progresses.

-To avoid an electrical shock, neither remove the protection cover 

nor  handle  the  connected  wire  in  the  terminals  without  first 
disconnecting the power supply.

-Do not block ventilation holes of the unit so that air can circulate freely.
-To avoid damage, the power supply has to be firmly fixed.
-Once  the  power  supply  has  been  installed,  place  the  supplied 

protection cover on the mains input connector ('N' & 'L').

-Before switching the system on, check that there is no shortcircuit 

on the installation.

-In case of system failure, unplug it from mains by using the thermo-

magnetic circuit breaker and contact an authorised Golmar after 
sales service.

-This document must be kept together with the device.

TFA-G2+ EN

   Cod. 50124334

    AC Input
100~240Vac

*

*

3

2

1

When the installation and wiring works are finished, place the 
    protection cover before replacing the electrical current.

Din rail.

       N

L

LED

L

       N

L

L

N:

 

AC input.

L:
L:

 

AC input.

AC input.

BUS(M) BUS(PL)