Rev.0122
FA-G2+ POWER SUPPLY INSTRUCTIONS
1. Introduction:
2. Terminal description:
4. Wiring:
Open the AC protection cover:
1. Remove the protection cover
fixing screw
2. Push up the protection cover.
5. Specification:
Input Voltage:
Input Frequency:
Rated Output Voltage:
Rated Output Current:
Working Temperature:
Dimensions:
100~240Vac
50~60 Hz
30 Vdc
±
2V
5A
1,
-10ºC ~ 40ºC
140*90*60mm
3. Installation:
1: Mount the din rail to the wall with wallplugs and screws that
are suplied with power supply.
2: Place the power supply simply pressing it.
LED: Power indicator, always on when plug in power.
BUS(M): Monitor connection bus terminal.
BUS(PL): Door panel connection bus terminal.
Note:
The installation and handling of this equipment must be
performed by authorised personnel and without the power
connected.
6. Warning:
Golmar reserves the right to make any modifications without prior notice.
Din rail.
DIN rail latch release.
BUS(M)
Connect to monitor
Connect to door panel
BUS(PL)
FA-G2+ power supply has been exclusively designed to be used
on Golmar G2+ video door entry. Golmar will not be responsible of
the possible damages caused for an improper use or when used
for other purposes than the specified.
Features:
- Universal AC input/full range.
- Multi protection: Short circuit and overload.
- Integrated with Bus splitter (monitor/ door panel).
- Additional Bus splitter (monitor/ door panel) is not needed.
- DIN 46277 rail mounting.
3. Next pull it out.
-This device has been exclusively designed to be used on Golmar
G2+ video door entry system. Golmar will not be responsible of the
possible damages caused for an improper use or when used for
other purposes than the specified.
-The installation and handling of this equipment must be performed
by authorised personnel and without the power connected.
-Install the power supply in a dry and protected place with enough
ventilation, without risk of drip or water projections.
-Install the power supply according to your country rules.
-Do not use excesive force when tightenning the power supply
connector screws.
-The device must be protected by using a thermo-magnetic circuit
breaker.
-The power supply must be unplugged from mains during
installation or maintenance progresses.
-To avoid an electrical shock, neither remove the protection cover
nor handle the connected wire in the terminals without first
disconnecting the power supply.
-Do not block ventilation holes of the unit so that air can circulate freely.
-To avoid damage, the power supply has to be firmly fixed.
-Once the power supply has been installed, place the supplied
protection cover on the mains input connector ('N' & 'L').
-Before switching the system on, check that there is no shortcircuit
on the installation.
-In case of system failure, unplug it from mains by using the thermo-
magnetic circuit breaker and contact an authorised Golmar after
sales service.
-This document must be kept together with the device.
TFA-G2+ EN
Cod. 50124334
AC Input
100~240Vac
*
*
3
2
1
When the installation and wiring works are finished, place the
protection cover before replacing the electrical current.
Din rail.
N
L
LED
L
N
L
L
N:
AC input.
L:
L:
AC input.
AC input.
BUS(M) BUS(PL)