background image

12

13

V

in

V

out

Malla

Shield

Malla

Shield

A

HZ-

INT

SA

CTO

2C

A1

VP

MP

D

REF

RCPL-PLUS

LOTE

CODE

11758882

Colocar la parte superior de la regleta a 1,60m. del suelo.

Place the top part of the monitor connector at 1,60m. from the floor.

50mm.

50mm.

Presionar para abrir.

Press to open.

Ter, – and Malla (shield) are duplicated for easiest cascade installation of parallel
     monitors or telephones. If the first monitor is not placed on the connector, cascade units
     will not be powered.

escription of the RCPL-Plus 

D

monitor connector.

a

a

b

b

f

e

d

c

a. Wall attachment hole (x4).
b. Monitor attachment hook (x2).
c. Vertical wiring input.
d. Attachment clip.
e. Wiring input hole.
f.  Installation terminals:

positive, ground.
video signal coaxial input.
coaxial shield.
video signal coaxial output.
audio communication.
digital communication.
door bell push button input.
intercom.
auxiliary calling device output.
video distributor activation output.
2nd camera activation output.
optional device activation output.
twisted pair video signal.

+, –:
Vin :
Malla:
Vout :
A :
D :
HZ- :
INT :
SA : 
CTO :
2C :
A1 :
Vp, Mp :

L561 module for video installations 

E

with twisted pair cable.

andling the end of line jumper.

H

hanging the front film.

C

The end of line jumper is placed on the CN4 connector, that can be
     located on the monitor base.
     In case of twisted pair cable installations, the end of line jumper
     is placed in the EL561 module, also located in the CN4 connector
     of the monitor base.

Do not remove the jumper on monitors where the video cable finish.
     Remove the jumper on monitors where the video cable continue.

The monitor is supplied with a reversible front film, that allow the owner
     to choose between two colors.
To change the front film, remove the front plate by inserting a plain screwdriver
     in the triangle marks, as it is shown on the drawing.

MONITOR ADJUSTMENTS

MONITOR CONNECTOR DESCRIPTION

Locate the CN4 connector, that's placed in the monitor base.
     Remove the existing jumper and plug the EL561 module.

NOTE: on this type of installations the EL560 module must be
     plugged in the CN4 connector of the panel (page 7).
     Refer to the specific installation diagram.

Содержание 295 Series

Страница 1: ...T300EN rev 0204 Instructions manual Audio and Video door entry system digital installation 295 Series...

Страница 2: ...roubleshooting hints 29 INTRODUCTION First of all we would like to thank and congratulate you for the purchase of this product manufactured by Golmar The commitment to reach the satisfaction of our cu...

Страница 3: ...thout the visitor being aware of this To see the picture in a slave monitor press the push button dissapearing the picture on the other monitor If the call is not answered in 45 seconds the system wil...

Страница 4: ...CD 295 2nd push buttons module CD 295 2nd push buttons module CD 295 L1 L2 CD1 CN2 CD2 CP L1 L2 CN1 CP CD L1 L2 CN1 CP CD 1 9 17 3 11 19 5 13 21 7 15 23 8 16 24 6 14 22 4 12 20 2 10 18 DOOR PANEL INS...

Страница 5: ...eneral entrance panel this function can be activated in one door panel of each internal building Set to ON the switch number 2 for monitor or telephones programming Once the programming progress is fi...

Страница 6: ...el C Fix the door panel to the embedding box by using the supplied vandal resistant screws and the special screwdriver inal adjustments F To install the power supply directly on the wall drill two hol...

Страница 7: ...O Floor Door Stair PLATEA Plus 0000000000 N serie a f g b e j l k m d i c h a b c d e f g h i j k l m Handset B W or color screen depending on the model Front film Function push buttons Cord Attachmen...

Страница 8: ...onal device activation output twisted pair video signal Vin Malla Vout A D HZ INT SA CTO 2C A1 Vp Mp L561 module for video installations E with twisted pair cable andling the end of line jumper H hang...

Страница 9: ...e In systems with more than one door panel the programming process shall be done on the master door panel only Switch off the monitor to be programmed Once the monitor is off press the door release pu...

Страница 10: ...allows to call to the master porter s exchange During call reception and communication progresses allows the lock release activation a b c a b c erminal connector description T positive ground audio d...

Страница 11: ...slaves both monitors or telephones Make a call to check that the telephone has been succesfully programmed Repeat these steps to program the rest of telephones Once the programming has been finished s...

Страница 12: ...econd panel as shown on the diagram In case of more than two door panels wire them as the second is connected 1 00mm 2 50mm 0 25mm 0 25mm RG 59 RG 59 Terminal SECTIONS CHART 50m Distance 150m A A A D...

Страница 13: ...M in out p d p d CV CV CTO CT For longer distances than the specified contact with your distributor ideo installation without coaxial cable v The installation diagram shows the connection of a video s...

Страница 14: ...door panels for the same building If the system has one door panel only override the wiring to the second door panel If the system has more than one door panel wire the second panel as shown on the di...

Страница 15: ...connector it will be possible to view the picture from the door panel on the TV screen Remove the end of line jumper that s placed on the CN4 connector Connect the coaxial cable between terminals 17...

Страница 16: ...wiring from the door panel and to check a monitor or telephone directly connected to the door panel No shortcircuit will damage the connected units with the exception of a shortcircuit between CTO and...

Страница 17: ...el derecho a cualquier modificaci n sin previo aviso Golmar se r serve le droit de toute modification sans pr avis Golmar reserves the right to make any modifications without prior notice golmar golma...

Отзывы: