background image

28

29

OPTIONAL CONNECTIONS

TROUBLESHOOTING HINTS

HZ-

-

SA

+

T

T

R

R

M

M

SAR-90

A

_

+

D

2C

Malla

V

in

V

out

CN4

oor bell push button connection.

D

The Platea Plus monitor and the T-940 Plus telephone can be used to receive the calls made
     from the apartment door, saving the use of a bell. Wire the push button of the apartment
     door to the 'HZ ' and ' ' monitor or telephone terminals.
The reproduced acoustic tones are different depending on their provenance, that allows the
     user to distinguish where the call is made from. If during a conversation a call is made from
     the apartment door, acoustic tones will be reproduced on the hanset to advise that someone
     is calling.

ctivation of a second camera.

A

The use of a SAR-90 relay will be required to activate a second camera and an internal
     modification on the monitor shall be done, as it's described on page 11.
This facility disables the intercom function. If both functions are required, use A1 terminal to
     activate the second camera.
To activate this function, press    monitor push button at any moment with no dependence of
     the handset position.
 If this device is shared for all the monitors, link their 2C terminal and use just one relay unit.
     In case that each monitor has its own camera use a SAR-90 relay unit for each monitor
     and don't link the 2C monitor terminals.
This push button can be used to activate other auxiliary devices, as the A1 terminal is used.
Usual applications are the surveillance of the elevator entrance, reception hall, ...

An easy way to check that the system is working properly is to disconnect the wiring from the door 

panel and to check a monitor or telephone directly connected to the door panel.

No shortcircuit will damage the connected units, with the exception of a shortcircuit between 

CTO and ' ' monitor or distributor terminals.

O

Nothing operates.

w

Check the output power supply voltage between ' ' and '+' terminals: it should have 17,5 to 

18,5Vd.c. If not, disconnect the power supply from the installation and measure again. If 
it's correct now, it means there is a short circuit in the installation: disconnect the power 
supply from mains and check the installation.

w

Check that 'D' terminal is not shortcircuited with ' ' or '+' terminals.

w

Check that 'D' terminal hasn't been changed by 'A' terminal somewhere in the installation.

O

Inappropriate audio level.

w

Adjust the level volumes as shown on page 8. In case of feedback, reduce the audio levels 

until feedback fade out. If feedback don't dissapears refer to the following hint.

O

Continuous audio feedback.

w

Check that 'A' terminal is not shortcircuited with other terminals.

O

Door open function no operates.

w

Remember that this function is only available during call and communication progresses.

w

Disconnect the lock release from the main module and short-circuit terminals ' ' and 'CV ': at 

that moment the output voltage between terminals 'CV+' y 'CV ' should be 12Vd.c. If it's 
so check the lock release and its wiring.

O

The system cannot be programmed.

w

Check that the switch number 2 of the configuration dip switch is set to ON (see page 7) and 

that the programming steps are correctly followed.

w

Check that 'D' terminal is not shortcircuited with other terminals.

O

Some units don't receive calls.

w

Remember that each apartment must have a master unit only. Check that the units are 

switched on and correctly programmed.

Содержание 295 Series

Страница 1: ...T300EN rev 0204 Instructions manual Audio and Video door entry system digital installation 295 Series...

Страница 2: ...roubleshooting hints 29 INTRODUCTION First of all we would like to thank and congratulate you for the purchase of this product manufactured by Golmar The commitment to reach the satisfaction of our cu...

Страница 3: ...thout the visitor being aware of this To see the picture in a slave monitor press the push button dissapearing the picture on the other monitor If the call is not answered in 45 seconds the system wil...

Страница 4: ...CD 295 2nd push buttons module CD 295 2nd push buttons module CD 295 L1 L2 CD1 CN2 CD2 CP L1 L2 CN1 CP CD L1 L2 CN1 CP CD 1 9 17 3 11 19 5 13 21 7 15 23 8 16 24 6 14 22 4 12 20 2 10 18 DOOR PANEL INS...

Страница 5: ...eneral entrance panel this function can be activated in one door panel of each internal building Set to ON the switch number 2 for monitor or telephones programming Once the programming progress is fi...

Страница 6: ...el C Fix the door panel to the embedding box by using the supplied vandal resistant screws and the special screwdriver inal adjustments F To install the power supply directly on the wall drill two hol...

Страница 7: ...O Floor Door Stair PLATEA Plus 0000000000 N serie a f g b e j l k m d i c h a b c d e f g h i j k l m Handset B W or color screen depending on the model Front film Function push buttons Cord Attachmen...

Страница 8: ...onal device activation output twisted pair video signal Vin Malla Vout A D HZ INT SA CTO 2C A1 Vp Mp L561 module for video installations E with twisted pair cable andling the end of line jumper H hang...

Страница 9: ...e In systems with more than one door panel the programming process shall be done on the master door panel only Switch off the monitor to be programmed Once the monitor is off press the door release pu...

Страница 10: ...allows to call to the master porter s exchange During call reception and communication progresses allows the lock release activation a b c a b c erminal connector description T positive ground audio d...

Страница 11: ...slaves both monitors or telephones Make a call to check that the telephone has been succesfully programmed Repeat these steps to program the rest of telephones Once the programming has been finished s...

Страница 12: ...econd panel as shown on the diagram In case of more than two door panels wire them as the second is connected 1 00mm 2 50mm 0 25mm 0 25mm RG 59 RG 59 Terminal SECTIONS CHART 50m Distance 150m A A A D...

Страница 13: ...M in out p d p d CV CV CTO CT For longer distances than the specified contact with your distributor ideo installation without coaxial cable v The installation diagram shows the connection of a video s...

Страница 14: ...door panels for the same building If the system has one door panel only override the wiring to the second door panel If the system has more than one door panel wire the second panel as shown on the di...

Страница 15: ...connector it will be possible to view the picture from the door panel on the TV screen Remove the end of line jumper that s placed on the CN4 connector Connect the coaxial cable between terminals 17...

Страница 16: ...wiring from the door panel and to check a monitor or telephone directly connected to the door panel No shortcircuit will damage the connected units with the exception of a shortcircuit between CTO and...

Страница 17: ...el derecho a cualquier modificaci n sin previo aviso Golmar se r serve le droit de toute modification sans pr avis Golmar reserves the right to make any modifications without prior notice golmar golma...

Отзывы: