— 31 —
CHECK : 1. POWER SUPPLY
2. FUSE (See "CHECKOUT PROCEDURE FOR FUSE BLOWING" on page 25.)
3. OVEN CAVITY THERMOSTAT
PROBLEM A :
"0" does not appear in display window when power
supply cord is plugged into wall outlet.
1
120V
120
120
Voltage
incorrect.
Contact
OK
Normal
circuit board
Normal
resistance
SEQUENCE
Runs
C. TROUBLESHOOTING
Before following this troubleshooting read "TRIAL OPERATION" on page 5.
• "DISPLAY" Problems, "A" thru "C"
• "HEAT UP" Problems, "D" thru "E"
• "TEMPERATURE CONTROLLED COOKING" Problems, "F"
RESULT
Replace
circuit board
Runs
1
PROBLEM B :
Display does not show correct numbers and/or
correct indications when programmed.
Measure resistance
of touch key borad
after removing
connector S1.
(See page 14 and 28)
Normal
resistance
Resistance
incorrect
Check contact
of connentor
S1
Poor
contact
Replace
circuit board
Correct
seating
Normal
contact
Runs
Runs
Runs
Replace touch
key board.
Normal touch
key board
Correct
connections
Normal
circuit board
WH
RD
• "BUZZER" Problems "G"
Measure voltage
between pin 1 and
pin 4 of connector CN1.
Содержание MV-1155W
Страница 8: ...6 OVERALL CIRCUIT DIAGRAM A SCHEMATIC DIAGRAM 7 ...
Страница 40: ...CONTROLLER PARTS 38 WTT028 WTT021 WTT021 268711 24810P 26638A 07 23572A 24781M WTT021 EV ...
Страница 42: ...LATCH BOARD PARTS 40 WSZ085 43500A 466001 466004 466002 43510A 466003 43501A EV ...
Страница 45: ...INTERIOR PARTS III 43 WTT021 53551S 53551L WSZ002 WSZ002 53551R 568772 WTT021 WTT021 EV ...