(3) CHECKOUT PROCEDURES FOR CIRCUIT
BOARD.
The following symptoms indicate a defective circuit
board.
1) The start function fails to operate but the high voltage
systems, the interlock switches, the door sensing and
the relay check good.
2) The unit with a normal relay continuously operates.
3) Proper temperature measurement is not obtained.
4) The buzzer does not sound or continues to sound.
5) Some segments of one or more digits do not light up,
or they continue to light up, or segments when they
should not.
6) Wrong figures appear.
7) The figures of all digits flicker.
8) Some of the indicators do not light up.
9) The clock does not keep time properly.
— 30 —
NOTE: A MICROWAVE ENERGY LEAKAGE TEST MUST ALWAYS BE PERFORMED WHEN THE UNIT IS
SERVICED ANY REASON.