5-13
CONDITION
CHECK
RESULT
CAUSE
REMEDY
1. Fuse blows.
Continuity.
No continuity.
Continuity.
Shorted contact at
the primary switch.
Replace fuse,
primary, monitor,
secondary
switches, and
RELAY(RY2) of
P.C.B Assembly.
No continuity.
Normal.
Defective high
voltage capacitor.
Replace high
voltage capacitor.
Fuse blows again
Defective high volt-
age transformer.
Replace high volt-
age transformer.
Malfunction of the
monitor switch.
Replace fuse,
primary, monitor,
secondary
switches, and
RELAY(RY2) of
P.C.B Assembly.
Check continuity
of monitor
switch (with
door closed).
Check continuity
of primary
switch (with
door opened).
Disconnect one
side of the wire
lead connected
from transformer
to the high
voltage
capacitor and
operate the unit.
Replace fuse
Continuity.
Malfunction of
secondary switch.
Replace fuse,
primary, monitor,
secondary
switches, and
RELAY(RY2) of
P.C.B Assembly.
No continuity.
Check continuity
of secondary
switch (with
door opened).
2. Fuse does not
blow.
No continuity.
Continuity.
No continuity.
Defective power
supply cord.
Replace power
supply cord.
Defective
thermostat.
Replace
thermostat.
Check continuity
of thermostat.
Check continuity
of power supply
cord.
(TROUBLE 2) Oven does not operate at all, Display window does not display any figures,
and no input is accepted.
NOTE : All these switches must be replaced at the same time. Refer to page 5-7, 5-8
Содержание MA-2003B
Страница 27: ...6 2 13213A 13552A 13581A 13536A 14026A 14970A 13352A 13720D DOOR PARTS ...
Страница 28: ...6 3 26638A 23572A 268711 WTP018 24970A 250201 24781M 23550D 24510L CONTROLLER PARTS ...
Страница 29: ...6 4 948503 340511 33052M 36549S 34036W 33390G 35889A WTP013 WTT010 WTT021 33112U OVEN CAVITY PARTS ...
Страница 30: ...6 5 43501A 43500A 466001 WSZ085 466001 466003 LATCH BOARD PARTS ...
Страница 32: ...6 7 63302L 65006B 948501 56170D WSZ002 WTT021 BASE PLATE PARTS 63302R 63303R 63303L ...