5-8
CAUTIONS
1. DISCONNECT THE POWER SUPPLY CORD FROM THE OUTLET WHENEVER REMOVING THE
OUTER CASE FROM THE UNIT. PROCEED WITH THE TEST ONLY AFTER DISCHARGING THE HIGH
VOLTAGE CAPACITOR AND REMOVING THE WIRE LEADS FROM THE PRIMARY WINDING OF THE
HIGH VOLTAGE TRANSFORMER. (SEE PAGE 2-1)
2. ALL OPERATIONAL CHECKS WITH MICROWAVE ENERGY MUST BE DONE WITH A LOAD (1 LITER
OF WATER IN CONTAINER) IN THE OVEN.
COMPONENTS
TEST PROCEDURE
RESULTS
HIGH VOLTAGE
TRANSFORMER
(Wire leads removed)
MAGNETRON
(Wire leads removed)
1. Measure the resistance.
(Ohm-meter scale: Rx1 and Rx100)
• Primary winding
• Secondary winding
• Filament winding
2. Measure the resistance.
(Ohm-meter scale: Rx1000)
• Primary winding to ground
• Filament winding to ground
1. Measure the resistance.
(Ohm-meter scale: Rx1)
• Filament terminal
2. Measure the resistance.
(Ohm-meter scale: Rx1000)
• Filament to chassis
Approx.: 0.2 ~ 0.4 ohm
Approx.: 60 ~ 90 ohm
Less than: 1 ohm
Normal: Infinite
Normal: Infinite
Normal: Less than 1 ohm
Normal: Infinite
PRIMARY
TERMINAL
SECONDARY
FILAMENT
WINDING
COMPONENT TEST PROCEDURE
Содержание MA-2003B
Страница 27: ...6 2 13213A 13552A 13581A 13536A 14026A 14970A 13352A 13720D DOOR PARTS ...
Страница 28: ...6 3 26638A 23572A 268711 WTP018 24970A 250201 24781M 23550D 24510L CONTROLLER PARTS ...
Страница 29: ...6 4 948503 340511 33052M 36549S 34036W 33390G 35889A WTP013 WTT010 WTT021 33112U OVEN CAVITY PARTS ...
Страница 30: ...6 5 43501A 43500A 466001 WSZ085 466001 466003 LATCH BOARD PARTS ...
Страница 32: ...6 7 63302L 65006B 948501 56170D WSZ002 WTT021 BASE PLATE PARTS 63302R 63303R 63303L ...