ELECTRICAL DATA
BEFORE CALLING FOR SERVICE
Line Cord Plug
Use Wall Receptacle
Power Supply
Do not, under any
circumstances, cut
or remove the
grounding prong
from the plug.
Power supply cord with
3-prong grounding plug
• Air Conditioner will not operate.
1. Is the air conditioner plugged into the outlet?
2. Is the fuse or breaker good?
3. Is the voltage unusually high or low?
• Air from the unit does not feel cold enough on the cooling setting.
1. Is the setting temperature correct?
2. Is the air filter clogged with dust?
3. Is the air flow from the outside(condensers) obstructed?
Leave a clearance of over 1 meter(3
1
/
4
feet) between the back of the air conditioner and the wall or
fence behind it.
4. Are the door or windows open, or is there any source of heat in the room?
NOTE: If it is difficult to find out the cause of the trouble, be sure to turn the air conditioner off and
contact the dealer.
• OFF-SEASON MAINTENANCE
1. Clean the air filter and re-install.
2. Turn the operation knob to OFF and disconnect the power plug from the wall receptacle.
Use 20 AMP time
delay fuse or circuit
breaker.
Standard 250V, 3-wire grounding
receptacle rated 20A, 250V AC