9
T E C H N I C A L D ATA
DISTORTION
Figures valid for all levels from 0 to 40 V / 8 Ohms:
• Dynamic: TID < 0.01 % (- 80 dB).
• Static: THD < 0.01 % (- 80 dB).
SPEED
• Slew rate: > 200 V/us
• Rise time: < 300 ns.
NOISE
• Signal-to noise ratio: > 115 dB (0.01 Hz - 1 Mhz).
• Weighted ASA A: > 130 dB.
OPERATING TEMPERATURE
• Room temperature: -30 to +40 degrees Celsius (-22 to +104 degrees Fahrenheit).
• Internal temperature: +45 to +65 degrees Celsius (+113 to +149 degrees Fahrenheit).
POWER SUPPLY
• Nominal line voltage: 117, 234 V (switchable).
• Input voltage range: +/- 10 %.
• Maximum power consumption: 2000 W.
• Power used in standby: 120 W.
• 8 toroidal transformers, 4 separated power supply.
GROUNDING
• Separated ground and earth.
• Floating chassis connected to mains earth.
• Possible link for optionally connecting both.
User manual - GOLDMUND TELOS 600 UNIVERSAL POWER AMPLIFIER
|
P 15