8

T E C H N I C A L   D ATA

SAFETY FEATURES

• AC voltage fuse: min 16 A slow-blow .

FRONT PANEL CONTROLS

• 1 control key (Muting/Standby and 2 sec tempo for ON/OFF).
• Red Led display for Over-heating, DC offset or HF protection and Overload.
• Green Led display for Power ON, operating mode (blinking in standby).
• Yellow Led display for signal connection and digital Lock.

REAR PANEL CONNECTORS AND CONTROLS

• Power cord: universal socket 3 lugs.
• Main fuse (16 A slow-blow).
• Green-yellow AC earth binding post.
• Output speaker 2 x 5 ways post in parallel.
• Output speaker 2 x Coaxial connectors in parallel.
• Analog Input connector RCA.
• Digital Spdif input and output RCA connector.
• Input connector XLR for analog balanced input.
• Switch between analog or digital input.
• Switch right or left channel selection from the Spdif input.

SIZE AND WEIGHT

• 27 cm (11") W x 41 cm (16.5") D  x 23 cm (9") H.
• Weight: 30 kg net.

WARRANTY

• 3 years parts and labor.

User manual - GOLDMUND TELOS 400 UNIVERSAL POWER AMPLIFIER  

|

P 13

Содержание TELOS 400

Страница 1: ...USER MANUAL GOLDMUND TELOS 400 Universal Power Amplifier...

Страница 2: ...IER Goldmund was founded in 1978 and has ever since been dedicated to the accurate reproduction of sound and image At Goldmund we strive to lead in the creation development and manufacture of the indu...

Страница 3: ...eatures which are a necessity for accurate sound reproduction in the best audio systems Only careful installation and use can provide the satisfaction you are expecting The installation instructions m...

Страница 4: ...ION AND COOLING p 4 3 LINE VOLTAGE ADJUSTMENT p 5 4 CONNECTIONS p 6 5 AMPLIFIER CONTROLS p 7 9 6 SOUND QUALITY OPTIMIZATION p 10 7 SAFETY FEATURES p 11 12 8 TECHNICAL DATA p 13 CONTENTS User manual GO...

Страница 5: ...RESULT IN DAMAGE INVALIDATING WARRANTY COVER CHOICE OF AMPLIFIER LOCATION AND COOLING The GOLDMUND TELOS 400 amplifier as all high quality amplifiers generates a large amount of heat when driven at hi...

Страница 6: ...er for internal adjustment ATTENTION On the 220V position the GOLDMUND TELOS 400 amplifier will function properly for main line voltage between 190V and 245V On the 110V position the main line must de...

Страница 7: ...signal connect the digital input cable to the digital input and switch the input switch to digital Since a digital Spdif cable carries 2 channels you may link the digital output to the next amplifier...

Страница 8: ...white 10 position circular selector located on the top circuit of the amplifier close to the big capacitors There is one position for Manual operation and 9 for Auto Power operation Positions 1 throu...

Страница 9: ...yellow Led may flicker showing there is no lock and the amp remains muted until a lock is found With an analog input the amp is immediately operational and the orange Led illuminated The amp may be re...

Страница 10: ...ELOS 400 the front panel red light may turn ON and the power of the amplifier is instantaneously set OFF The red Led indicates an over temperature situation HF oscillation or DC signal has been detect...

Страница 11: ...amic capability and transparency especially on low efficiency speakers To get all the benefits of this design the TELOS 400 must be located on a very rigid support or better directly on the floor to b...

Страница 12: ...played on the front panel When the source of DC offset is suppressed turn ON the amplifier again Protection against HF oscillations In the same way the speaker must be protected against a large amount...

Страница 13: ...type of damage if the temperature rises too high a protection circuit switches the amp OFF automatically A red front panel light indicates that the amplifier has been turned OFF by the protection cir...

Страница 14: ...LS Power cord universal socket 3 lugs Main fuse 16 A slow blow Green yellow AC earth binding post Output speaker 2 x 5 ways post in parallel Output speaker 2 x Coaxial connectors in parallel Analog In...

Страница 15: ......

Отзывы: