GOLDMUND TELOS 352 - Universal Stereo Power Amplifier - 9
5
AMPLIFIER CONTROLS
As soon as the amplifier is connected to AC line and the amplifier has not detected an error
previously, the green light on the amp front panel is ON.
The TELOS 352 may be powered on either manually (Manual Operation) or automatically
when receiving a signal (Auto-Power Operation). This is selected internally by the small
white 10-position circular selector located on the top circuit of the amplifier, close to the big
capacitors.
There is 1 position for Manual operation (position 0) and 9 for Auto-Power operation.
Positions 1 through 9 enable various delays to be set. This supports powering-up a
quantity of amplifiers without a big surge on the AC line.
Position 0: Manual Operation
Position 1: Power after 500ms
Position 2: Power after 1s
Position 3: Power after 1.5s
Position 4: Power after 2s
Position 5: Power after 2.5s
Position 6: Power after 3s
Position 7: Power after 3.5s
Position 8: Power after 4s
Position 9: Power after 4.5s