SOUND QUALITY OPTIMIZATION (Ctd.)
SOUND QUALITY OPTIMIZATION (Ctd.)
SOUND QUALITY OPTIMIZATION (Ctd.)
SOUND QUALITY OPTIMIZATION (Ctd.)
6.4
MAIN LINE PHASE INVERSION
To select the proper phase, you have to select, by trying, one of the two power cord
positions. We recommend that you proceed carefully when trying this. You must do it in
combination with the speaker polarity and/or with absolute phase switching to be sure of
the result.
7
7
7
7
SAFETY FEAT U R E S
SAFETY FEAT U R E S
SAFETY FEAT U R E S
SAFETY FEAT U R E S
The GOLDMUND TELOS 250+ amplifier provides features to protect the amplifier and the
speakers against all mishandling or component failure. However precautions must be taken
to avoid problems with a very high power amplifier.
7.1
PROTECTION AGAINST DC
The TELOS 250+ is a DC-coupled amplifier. If the associated preamplifier is badly
designed or defective (often true for tube preamps), the speakers could be damaged.
In such a case, the DC protection circuit of the TELOS 250+ will automatically turn off the
amplifier. This detection circuit is totally immune to any sonic effect.
To indicate that the amplifier has been turned off by the protection circuit, the red led will
be illuminated on the front panel.
When the source of DC offset is suppressed, turn ON the amplifier again.