7 - SAFETY AND PRECAUTIONS  

 
 
 

Attention : 
 

The MIMESIS SRM2.3 are extremely high speed amplifiers.  
Any bad ground connection can generate high frequency oscillation which is dangerous for tweeters. 
It is also generally dangerous to run input cable and speaker cables in parallel for a long distance. If 
these cables are not of high quality or badly shielded, an “Antenna-Effect” can generate dangerous 
high-frequency oscillations. 
 
 

- Protection against DC. 
 

The MIMESIS SRM2.3 is a DC-coupled amplifier. Without protection and if the associated preamplifier 
is badly designed or defective (often true for tube preamps), the speakers could easily be damaged by 
the amplified DC.  
The SRM2.3 protects itself from such an accident by a feedback DC control that limits the DC 
amplified by the circuit.  
This protection circuit is totally transparent and has no sonic effect. 
 
 

- Protection against short-circuits. 
 

If one output is short-circuited by accident the amplifier is self-limiting its output so the current doesn’t 
become too high. 
However, such accident should be limited in time to avoid excessive heat-up to occur. In extreme 
cases, such mishandling could destroy the amplifier, which is not covered by the warranty.  
 
There is no risk to leave the speaker terminals unconnected when the amps are on. 
 
 
 
 
 

8 - MAINTENANCE 
 
 

The GOLDMUND MIMESIS SRM2.3 amplifier usually requires no maintenance. For the audio purists 
who want to keep their amp sounding as new, we only recommend that after a year or two, you have a 
technician or an official GOLDMUND representative readjust the DC offset. This very simple operation 
takes only two minutes and will give you the safety of long years of unmatched sound quality. 
 
To clean your MIMESIS use only a soft cloth slightly damp. Always turn the power off before cleaning 
your amplifier. 
 
 
 
 

Содержание MIMESIS SRM2.3

Страница 1: ...1 GOLDMUND MIMESIS SRM2 3 MONO AMPLIFIER ...

Страница 2: ... 3 MONO AMPLIFIER USER MANUAL ATTENTION No connection or manipulation must be done before reading those instructions Damage to the amplifier may result if the following instructions are not consciously understood and applied ...

Страница 3: ...erly ventilated and avoid putting other equipment on top of them 3 LINE VOLTAGE ADJUSTMENT An AC line voltage selection is possible inside the chassis Please ask your dealer for assistance if the line voltage provided is not appropriate ATTENTION On the 220V position the GOLDMUND MIMESIS SRM2 3 amplifier will function properly for AC voltages in between 200V and 245V On the 110V position the AC li...

Страница 4: ...o get the best sound of the amplifiers avoid any multiple plug or extension cord 5 AMPLIFIERS CONTROLS On the front plate of the GOLDMUND MIMESIS SRM2 3 amplifier you will find only one switch The POWER key used to power the amp on When turned ON the channel is immediately connected and the POWER led lights up The amps may be powered off by turning off the POWER switch at any time The led will fad...

Страница 5: ... polarity of both speaker cables at amp termination But since the line phase and the speaker polarity interfere to each other you have to experiment carefully all the combinations before picking the right one If your preamplifier has an absolute phase inverter this will interfere too If it has not don t forget the result will depend of the source most of the record and CD being recorded without ca...

Страница 6: ... circuit is totally transparent and has no sonic effect Protection against short circuits If one output is short circuited by accident the amplifier is self limiting its output so the current doesn t become too high However such accident should be limited in time to avoid excessive heat up to occur In extreme cases such mishandling could destroy the amplifier which is not covered by the warranty T...

Страница 7: ...ay 100 ns stable with frequency from DC to 200 kHz DISTORTION Figures valid for all levels from 0 to 20 V 8 Ohms Dynamic TID 0 01 80 dB Static THD 0 01 80 dB SPEED Slew rate 240 V us Rise time 260 ns NOISE Weighted ASA A 100 dB OPERATING TEMPERATURE Room temperature 30 to 40 degrees Celsius 22 to 104 degrees Fahrenheit Internal temperature 45 to 65 degrees Celsius 113 to 149 degrees Fahrenheit POW...

Отзывы: