On the back panel of the Goldmund Mimesis 22 preamplifier the POWER switch is 
used to power on the preamplifier. In regular use, this switch is left ON and the 
circuits of the preamplifier are activated or disactivated using the standby ON/OFF.  
 
When the POWER switch is switched ON, the preamp will become operative only 
after few seconds of warm up, to insure proper stabilization of all the circuitry and 
avoid any unwanted noises. After this delay, the output of the preamplifier is 
connected to the power amplifier. 
 
The preamp can be powered off by switching the POWER switch to the OFF position. 
A special safety circuit switches the preamp to muting, to avoid any disturbance to 
reach the power amplifier and the speakers, even if the preamplifier is disconnected 
from the AC plug by accident. 
However, to optimize the sound quality of the preamplifier and insure the best 
reliability, Goldmund recommends that the unit is left powered ON continuously and 
is only disactivated by the Standby function. 
 
 

- MUTING  
 

This switch turns off the output of the preamplifier, without disconnecting the power 
supply. It can be used to turn temporarily the volume down without touching the 
volume control. 
 
 

- VOLUME 

 
Each of the left and right level adjustment knob is acting on its separated channel. 
However, in order to make the use easier, when only one potentiometer is turned by 
hand, the second one is turning of the same dB quantity, insuring a perfect 
maintenance of the balance much more precise than with usual stereo potentiometer.  
 

- BALANCE 
 

By pressing the balance key, the electronic lock of the two potentiometers is 
disengaged. One potentiometer can be turned without effect on the second one by 
pressing the  
 

 
 
 
 
- INPUT SELECTION 

 
The 7 channel selection switches  
 

- TAPE

  

 

Содержание MIMESIS 22

Страница 1: ...1 GOLDMUND MIMESIS 22 ANALOGUE PREAMPLIFIER USER MANUAL...

Страница 2: ...2 GOLDMUND MIMESIS 22 ANALOGUE PREAMPLIFIER USER MANUAL...

Страница 3: ...eo computer and audio associated components Only a careful use can provide all the satisfaction you are expecting All handling must be performed according to the following instructions to avoid the pr...

Страница 4: ...and the preamplifier are also critical Ultra low reflection cables are absolutely mandatory In all typical cases Goldmund recommends using the special Goldmund Interconnect cables Note The Goldmund Mi...

Страница 5: ...more of these feet The two left feet being evacuating the transformer vibration it is better to act if possible on the right feet and to leave the left feet fully screwed in 4 LINE VOLTAGE ADJUSTMENT...

Страница 6: ...marked analog output to the balanced input of a power amplifier However you have to know this mode of connection is not providing you with the ultimate sonic quality that a Mimesis 22 is built for pr...

Страница 7: ...AC plug by accident However to optimize the sound quality of the preamplifier and insure the best reliability Goldmund recommends that the unit is left powered ON continuously and is only disactivated...

Страница 8: ...either the TAPE1 source machine in OFF position or the recording made by TAPE2 in ON position COPY 2 1 Same with both machine exchanged MONITOR Allows the control after recording or during a recording...

Страница 9: ...hnology the phase coherency of this source is not sufficient to allow a sufficient difference between the two positions The GOLDMUND exclusive Mechanical grounding In the Goldmund Mimesis 22 preamplif...

Страница 10: ...fter a year or two you have a technician or an official Goldmund representative readjust the DC offset This very simple operation takes only two minutes and will give you the safety of long years of u...

Страница 11: ...alid for all levels from 0 to 25 V Dynamic TID 0 01 80 dB Static THD 0 01 80 dB SPEED Slew rate of the amplification stages 500 V us Rise time 500 ns CROSSTALK Separation 90 dB between channels NOISE...

Страница 12: ...itch with Led control ABSOLUTE PHASE switch with Led control REAR PANEL CONNECTORS AND CONTROLS Power cord socket 3 lugs Mains fuse 1A slow blow Voltage selector 110 220 V Earthing post yellow green O...

Отзывы: