background image

TECHNICAL MANUAL

Содержание 103225

Страница 1: ...TECHNICAL MANUAL ...

Страница 2: ...or coal gas Natural gas is lighter than air In this case the gas detector should be installed near the ceiling It is advised to locate the alarm 30cm below the ceiling at a distance of about 1 5m away from gas appliances fig 1 b Liquid Petroleum Gas LPG Its specific gravity is heavier than air so it sinks to the bottom As such it is advised to install the alarm 30cm above the floor at a distance o...

Страница 3: ... warranted against manufacturing defects for two years from the date of purchase In the event of defects Goldmedal will repair or at its discretion replace the warranted product if delivered to a Goldmedal authorized dealer along with a duly stamped guarantee card or sales receipt that shows the date of purchase along with the serial no of the product This warranty excludes defects due to abnormal...

Страница 4: ...pening is to pull the red handle up with a hand The opening status will be kept by the valve itself NOTE If there are difficulties to pull the red handle up with a hand special steps should be taken to balance the pressure at the outlet and inlet of the valve and then try opening again The opening status The valve will be closed automatically due to the magnetic lock design when harmful shaking vi...

Страница 5: ...ol wires should be connected correctly The wires have polarity The white one is positive and the black one is negative They should not be connected reversely When doing gas pipeline cleaning the valve should be covered in order to avoid damage to the valve seal materials The valve should be in opening status before the pipeline seal check with the test pressure The valve opening with hands can be ...

Страница 6: ...y saving switch 102212 A B B C C D A Indicator B Twilight Sensor threshold adjustment C Timer Adjustment D Switch Operations Light Settings The Passive Infrared Detector and Smart Passive Infrared Detector both have settings for light detection and time delays The light detection option allows you to decide the light intensity at which the associated device should be switched ON If you move the Li...

Страница 7: ...ether incidental consequential or otherwise Safety instruction Electrical equipment must be installed and fitted by a qualified electrician only The electronic switches are single pole switches and disconnect only one pole when they are OFF Before working on the appliance to prevent electric shock disconnect both the poles of the main supply Failure to observe any of the installation instructions ...

Страница 8: ...ruction Sheet S W I T C H E S S Y S T E M S ILLUMINATING IDEAS PUMP SETS APPLIANCE MCB RATING 0 50 HP 1 00 HP 2 00 HP 6 A 10 A 16 A WASHING MACHINE 1 30 KW 1 80 KW 2 20 KW 6 A 10 A 16 A RECOMMENDED MCB RATING AIR CONDITIONERS APPLIANCE MCB RATING 0 75 KW 1 00 KW 2 20 KW 6 A 10 A 16 A WATER ROOM HEATER 1 00 KW 2 00 KW 3 00 KW 6 A 10 A 16 A 101077 101078 101079 101080 101081 101082 102083 102084 102...

Страница 9: ......

Страница 10: ...polycarbonate material 101093 47 2 33 6 240 V L N Load Wiring Diagram for protection device fuse unit Dimensions mm Elevation and side view show overall dimensions and flush depth Dismantling of assembly Assembling view Rear housing Front plate Glass Fuse Fuse holder Replacement of blown glass fuse Fuse Technical Characteristics Instruction Sheet S W I T C H E S S Y S T E M S ILLUMINATING IDEAS 10...

Отзывы: