Page 7
Bench cut out and cooktop dimension by model number.
According to Australian regulations, the minimum clearance between a gas cooktop element or burner
component is:
•
600mm of vertical clearance to a combustible surface, and 200mm of horizontal distance to a verti-
cal surface. If these measurements can't be met, the surface in question must be protected with a fire
resistant material in accordance with
AG/601
.
•
600mm to a rangehood
•
750mm to an exhaust fan.
It's worth noting that with exhaust fans and rangehoods there isn't a specific clearance requirement un-
der the Building Code of Australia. Like all appliances though, these need to be installed according to
statutory requirements, and so that the installation meets the manufacturer
’
s specifications.
The Standard also states that the horizontal clearance from a hotplate or burner to a vertical combus-
tible material (like an acrylic splashback, for example) should be over 200mm. If not, the splashback or
other material needs to be protected with a non
-
combustible material to a height of 150mm for the full
length of the cooker.
See specs table on page 6 for details of bench cut out and other important information for each model.
The following is a guide to your installation layout.