Gas connection
Install in accordance with relevant gas standards and
/
or codes of practice applicable
.
Connect the elbow fitting to the appliance gas
manifold connection
,
and check that seal
s between the elbow and manifold connection are in place and in good condition.
For Natural gas : connect the natural gas appliance regulator (pictured opposite) with integral test point using approved gas thread tape or
compound to the elbow fitting.
For Universal LPG : connect the Test point adapter (pictured below) with integral test point using approved gas thread tape or compound to
the elbow fitting.
LPG testpoint
Natuaral Gas Reguator
i
n
l
e
t
c
Ensure the supply connection point
,
test point and natural gas regulator adjustment screw
(
for Natural gas installation
)
are acces-
sible for testing and
/
or adjustment with the hotplate in the installed position
.
Where a flexible hose assembly is used
,
ensure it is
approved to AS
/
NZS 1869
,
Class B or D with max
.
length of 1
.
2m
.
Any hose assembly used must be restrained from accidental
contact with the flue outlet of an under bench oven
.
This hose assembly shall be suitable for connection to a fixed consumer
piping outlet located as follows
:
Hotplates at a point 800 mm to 850 mm above the floor and in the region outside the width of the
appliance to a distance of 250 mm
.
Note:
If clearance between side and rear walls and periphery of the burner is less than 250mm, the walls must be protected with a
non
-
combustible
The protection must
minimum distance of 450mm above the burner. Horizontal surfaces less
than 650mm vertically above the hotplate must also be protected.