![Golden engineering XRS4 Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/golden-engineering/xrs4/xrs4_operators-manual_2240549015.webp)
13
MULTIPLE PULSE TRAINS
Option is used to enter multiple pulse trains and rest period between each pulse train.
¾
If multiple pulse trains are entered Multi-Trains set Continue screen appears when unit is powered up.
¾
Operator must select Y and press enter to continue with multiple pulse trains.
¾
If operator does not select Y and press enter the unit will default to a single pulse train. This safety fea-
ture ensures operator’s knowledge that multiple pulse trains are set.
¾
Red X-ray pulse light blinks between multiple pulse trains.
Multiple pulse train option can be used slow the pulse rate to one pulse per second by entering a pulse count of
one, enter desired number of pulse trains (pulses), and select one second between pulse trains.
Select Multiple Trains press Enter
Select pulse trains 1 to 999
Select seconds between pulse trains and save
Must select Y to continue
Home screen Appears with * to designate multiple pulse trains.