just not turn ON at all. We do not have an answer as to why the GFCI was
fine in the beginning when supplying power to the sauna and then suddenly
starts causing problems for the sauna power supply. We recommended not
connecting the sauna power cord to a GFCI protected outlet.
5. Wall Outlet Melting
Solution:
A common problem with wall outlets is loose wiring on the
connection points of the terminals of the receptacle. A loose wire will also
make for a bad connection and cause an unusual amount of heat buildup.
Loose connections can also cause sparking in the junction box that can
result in arcing. You'll likely see burn marks around the terminals if this
happens. You will need to consult with an electrician to replace the wall
outlet. You will need to contact Customer Service if the power supply cord is
damaged as the power supply will need to be replaced.
6. Bluetooth
Solution:
Please note that you can only have a single device connected to
the Bluetooth at any given time. You must unpair your device before
connecting with another device. To do a master reset of the Bluetooth, you
will need to unplug the sauna power cord from the wall outlet for 15 minutes.
7. Color Lighting
Solution:
If your color light is not working, the issue with the light may have
to do with the connection(s) on the top side of the light fixture. Please go up
to the roof panel and disconnect the wire connection on the topside of the
light fixture. Then reconnect the wire connection making sure that it is snug
and tight. Return back to the sauna control panel to test the light. If the light
is still having issues, please contact our Customer Service.
8. Dedicated Power Outlet
Solution:
You have two options when it comes to a dedicate receptacle. You
have a true dedicated line if the receptacle is the only receptacle on the line
to the breaker in your electric panel box. You have a quasi-dedicated line if
you have multiple receptacles on a line to the breaker in your electric panel
box and you do not draw any power from the other receptacles when the
sauna is in operation. Both of these options are acceptable.
9. Bench Heat Emitters (not on all models)
Solution:
With regards to the lower heat emitters under the bench and on
the floor, these heat emitters operate a bit different than the wall heat
Page 28