Golden Designs DYN-HTR-1500-200 Скачать руководство пользователя страница 8

 

 

(Note: To set back to factory settings, hold down the TIME button for (5) seconds.  This will 
set all values back to default.)   

 

7)  The Dynamic Infrared Heater can be turned off by pressing the POWER button.  DO NOT 

TURN OFF THE 

MASTER POWER

 SWITCH ON THE REAR OF THE HEATER OR 

UNPLUG THE HEATER UNTIL THE FAN SHUTS DOWN.   If the heater is left on using the 
TIME function, there will be (5) second sound alert to let you know that the time is expiring.  
If no actions are taken, the heater will shut off.

 

 

 
 

Recommendations for Maximum Performance 

1.  Be sure not to place the heater in an area where the air flow or air movement is great.   

2.  Direct the outflow towards the center of the room and not against a solid structure, like a 

wall for example.  For larger areas, place the heater within a central location. 

3.  The Dynamic Infrared Heater is designed for maximum efficiency in the 68

F to 74

0

 F range.  

This is because of the ambient air moving through the heater and out constantly. 

4.  Existing HVAC heating system vents should be closed.  This allows the heater to function in 

an isolated area. 

5.  It is not recommended to operate heater in areas exposed to non-insulated concrete or 

metal walls.  Concrete floors should be covered to insulate the heat within the room. 

6.   If the heater filters become dirty or dusty, they must be cleaned for the heater to operate at 

its maximum efficiently. 

Care, Maintenance, and Storage

 

Before care or maintenance is applied, always unplug the cord from the receptacle.    The cabinet 
housing can be wiped down with water and a damp cloth or with furniture polish.  The heater has a 
washable filter.  The filter should be cleaned regularly to provide for maximum performance.  Once 
the filter is removed, run warm water through and over the filter to remove dirt and dust.  Shake all 
water residue from the filter and replace it back in the heater.  (Note: A mild soap can be applied to 
assist in removing dirt and dust from the filter) 
 
If the heater is not to be used for an extended period of time, it can be stored away.  Make sure the 
power is turned off and the cord is unplugged from the receptacle.  Wrap the cord around the 
handle on the rear of the portable heater.  Cover the heater to prevent dust from accumulating on 

Содержание DYN-HTR-1500-200

Страница 1: ...IRCUIT The Dynamic Infrared Heater works with your in home furnace to provide supplement heat Carefully and thoroughly read this manual before using the Dynamic Infrared Heater for the first time We r...

Страница 2: ...always be followed to reduce the risk of fire electric shock and injury to persons Please adhere to the following safety instructions The heater must be operated by an adult Keep heater out of the re...

Страница 3: ...0 9 in Thermostat Electronic Analog Heater Size 14 9 in x 13 in x 17 7 in Fan System Cross Flow Fan Net Weight 25 lbs Fan Noise Level 46 db Gross Weight 28 lbs BTU Approximately 5100 Cabinet Wood Dark...

Страница 4: ...ow Fan will continue to circulate the airflow after the power is turned off to circulate the warm air from the Dynamic Infrared Heater cooling the unit down D The LED Digital Display is a convenient s...

Страница 5: ...lug the power cord directly into a conventional 120V 15 amp outlet and press the MASTER POWER switch on the rear of the portable heater Then press the POWER button on the front control panel or on the...

Страница 6: ...e status will switch back to the temperature status 4 Again the default set temperature displayed on the LED display is 720 F By pressing the TEMP button the LED display will switch to the temperature...

Страница 7: ...set desired temperature reading is defaulted to 72 degrees Fahrenheit You see this displayed when you first turn on the heater The set desired temperature reading has nothing to do with calibrating t...

Страница 8: ...e closed This allows the heater to function in an isolated area 5 It is not recommended to operate heater in areas exposed to non insulated concrete or metal walls Concrete floors should be covered to...

Страница 9: ...front grill and rear air intake to make sure it is not being blocked by any kind of debris 3 PROBLEM a The portable heater will not turn on SOLUTION First test your outlet to make sure it has power Y...

Страница 10: ...gnal Cable or other relevant plugs may have become disconnected Please contact the manufacture for further troubleshooting 7 PROBLEM a The heat emitter is functioning and the air outflow is working bu...

Страница 11: ...transportation of the parts In addition you are responsible for insuring any parts shipped or returned You must present Dynamic with proof of purchase documents including the date of purchase Any evi...

Страница 12: ...12 Page Is Intentionally Left Blank...

Страница 13: ...mailed back within 60 days of purchase date along with proof of purchase Serial number S N is located on the heater s front panel rear panel or on the carton DETACH HERE AND MAIL BOTTOM PORTION WITH...

Отзывы: