BUILDING CODES AND SAFETY STANDARDS

The design of this FIREPLACE ACCESSORY has been tested and is listed with CSA
INTERNATIONAL in accordance with THE AMERICAN NATIONAL STANDARDS
INSTITUTE - ANSI Z21.50, CSA Test Report No. 188842-1049553

This manual serves only as a basic guideline for installation and use of this firebox and
gas piping.  The complete installation must be in accordance with local codes and
ordinances, or, in the absence of local codes, with the American National Standards
Institute National Fuel Gas Code Z223.1 latest edition.

GENERAL INFORMATION

MODEL SF4224-TV IS A TOP-VENTED GAS FIREPLACE.  IT IS DESIGNED TO BURN
BY DRAWING COMBUSTION AIR FROM THE OUTSIDE AIR KIT THAT ATTACHES TO
THE LEFT SIDE OF THE FIREPLACE.

THE EXHAUST FLUE GASES ARE TO BE VENTED THROUGH THE TOP-VENT
USING 8" B-TYPE GAS VENT PIPE.  ALL-FUEL CLASS A CHIMNEY PIPE MAY ALSO
BE USED.

THE CONTROL SYSTEM IS A MILLIVOLT TYPE THAT INCLUDES A ON-OFF SHUT-
OFF VALVE, A GAS CONTROL VALVE, A STANDING PILOT LIGHT ASSEMBLY,
PIEZO IGNITOR AND ON-OFF ROCKER SWITCH.

WARNING:  THIS UNIT IS NOT FOR USE WITH SOLID FUEL.

NOTE:  INSTALLATION AND REPAIR SHOULD BE DONE BY A QUALIFIED SERVICE
PERSON.  THE APPLIANCE SHOULD BE INSPECTED BEFORE USE AND AT LEAST
ANNUALLY BY A PROFESSIONAL SERVICE PERSON.   MORE FREQUENT
CLEANING MAY BE REQUIRED DUE TO EXCESSIVE LINT FROM CARPETING,
BEDDING MATERIAL, ETC.  IT IS IMPERATIVE THAT THE UNITS CONTROL
COMPARTMENT, BURNERS, AND CIRCULATING AIR PASSAGE-WAYS BE KEPT
CLEAN TO PROVIDE ADEQUATE COMBUSTION AND VENTILATION AIR.

CLEARANCES REQUIRED

MINIMUM CLEARANCES FOR THE FIREBOX ARE:

1/2" ON THE SIDES AND BACK AND 0 AT THE BOTTOM.  TOP CLEARANCE IS 3"
WHICH IS THE HEIGHT OF TOP STANDOFFS, SEE FIGURE 7.1 FOR FRAMING
DIMENSIONS:

NOTE:  PROVIDE ADEQUATE CLEARANCES AROUND AIR OPENINGS INTO THE
COMBUSTION CHAMBER.

NOTE:  ADEQUATE ACCESSIBILITY CLEARANCES FOR SERVICING AND PROPER
OPERATION MUST BE PROVIDED IN ACCORDANCE WITH ANSI Z21.50 1998.

4

Содержание SUPER-FIRE SF4224-TV

Страница 1: ...ualified installer service agency or the gas supplier The Flue Damper must be in the full open position when burning the gas logs This fireplace is to be burned only with the gas log set supplied with the fireplace Burning other items could cause a fire hazard or injury For best results Natural Gas pressure should be 7 to 12 W C and 11 W C for Propane Gas To simulate real wood burning the gas burn...

Страница 2: ... and Safety Standards 4 Piping and Gas Pressure Requirements 5 Installation Instructions 6 Log Placement 9 Operating Guidelines 10 Lighting Instructions 12 Trouble Shooting 14 Replacement Parts 17 2 INSIDE ROOM FLUSH MOUNT CHASE CORNER MOUNT 61 86 5 44 INSTALLATION OPTIONS Figure 2 1 ...

Страница 3: ...SF4224 TV TOP VENT FIREPLACE INTERIOR VIEW Pan Burner Outside Air Control Knob Damper Control Lever Pilot Light On Off Switch Stand Offs Outside Air Port Damper Control Lever Valve Access Panel 3 ...

Страница 4: ...E USED THE CONTROL SYSTEM IS A MILLIVOLT TYPE THAT INCLUDES A ON OFF SHUT OFF VALVE A GAS CONTROL VALVE A STANDING PILOT LIGHT ASSEMBLY PIEZO IGNITOR AND ON OFF ROCKER SWITCH WARNING THIS UNIT IS NOT FOR USE WITH SOLID FUEL NOTE INSTALLATION AND REPAIR SHOULD BE DONE BY A QUALIFIED SERVICE PERSON THE APPLIANCE SHOULD BE INSPECTED BEFORE USE AND AT LEAST ANNUALLY BY A PROFESSIONAL SERVICE PERSON MO...

Страница 5: ... AT THE SUPPLY CONTAINER WILL LEAD TO GAS LEAKS AT THE CONTROL WITH POSSIBLE FIRE OR EXPLOSION Include a manual shut off valve and union in the line so the control or heater may be disconnected for servicing Include a drip leg and a plugged 1 8 N P T tapping into the line also The tapping must be accessible for the test gauge connection immediately upstream of the gas supply connection to the unit...

Страница 6: ...framing can be built before or after the fireplace is set in place Framing should be positioned to accommodate wall covering and fireplace facing material The fireplace framing should be constructed of 2 x 4 lumber or heavier The framing headers may rest on the fireplace standoffs Refer to Figure 7 1 for fireplace and framing reference dimensions CAUTION VERIFY FIREPLACE DIMENSIONS FRAMING METHODS...

Страница 7: ... near the base of a cliff or hillside The same situation can occur if the chimney is near other steep rooflines or tall buildings Areas with high winds also frequently require higher than normal chimneys Certain styles of architecture tend to interfere with a fireplace s draw If the room in which the fireplace is located has a very high ceiling smoke may enter the room unless the chimney is termin...

Страница 8: ...burner Refer to start up instructions on page 12 Important The fireplace damper must be in full open position 4 Place the grate over the burner and install the logs as illustrated on page 9 5 The last step is to cover floor of fireplace with volcanic rock around the sides and in front of burner pan to enhance overall appearance Note On L P models be careful not to pour black cinders over brass air...

Страница 9: ...ioned on the front of the grate The front bottom log pieces logs 2 and 3 should be touching each other in order to form what will look like a rotten or burned out chamber in the front log section see bottom left picture Log 4 and 5 should be placed on top of bottom logs as shown in bottom left picture Log 6 and 7 should be placed on top as shown in top right picture Bottom right picture shows fina...

Страница 10: ...ELINES Upon completing the gas line connection WARNING CHILDREN AND ADULTS SHOULD a small amount of air will be in the lines BE ALERTED TO THE HAZARDS OF HIGH When first lighting the pilot light it will SURFACE TEMPERATURE AND SHOULD STAY take a few minutes for the lines to purge AWAY TO AVOID BURNS OR CLOTHING themselves of this air Once the purging IGNITION YOUNG CHILDREN SHOULD BE is complete t...

Страница 11: ...teristics is necessary CAUTION THE LOGS CAN GET VERY HOT HANDLE ONLY WHEN COOL MAINTENANCE INSTRUCTIONS IMPORTANT THE APPLIANCE AREA MUST BE KEPT CLEAR AND FREE FROM COMBUSTIBLE MATERIALS GASOLINE AND OTHER FLAMMABLE VAPORS AND LIQUIDS Visually inspect pilot periodically Brush or blow away any dust or linen accumulations If pilot orifice is plugged disassembly may be required to remove any foreign...

Страница 12: ...s controls open valve access panel 3 Turn the control to the OFF position To do this you must turn the knob clockwise to the pilot position and then press in and continue turning clockwise to the OFF position 4 WAIT FIVE 5 MINUTES TO CLEAR OUT ANY GAS If you then smell gas STOP Follow B in the safety information above I you don t smell gas go to next step 5 The pilot should not require accessing f...

Страница 13: ...phone gas company and fire department Ask instructions Before hanging up give your name address and phone number DO NOT go back into building If your L P tank runs out of fuel turn off gas at the appliance After L P tank Is refilled appliance must be re lit according to manufacturer s instructions If The gas control has been exposed to WATER in any way DO NOT try to use it It must be replaced DO N...

Страница 14: ...at electrode off pilot and trigger the red button again If pilot lights an improper gas air mixture caused the bad lighting and a longer purge period is recom mended If pilot will not light check gap at electrode and pilot should be 1 8 inch to have a strong spark If OK replace pilot C No gas or low gas 1 Check remote shut off Pressure valves from fireplace usually there is a valve near the firepl...

Страница 15: ...nd TP terminals of gas valve Should read 325 millivolts minimum while holding valve knob depressed in pilot position pilot lit and ON OFF switch OFF Replace faulty generator if reading is below specified minimum B Defective valve 1 Connect the millivolt meter probes to the TH TP and TP terminals on the gas valve Turn knob to pilot position depress and light pilot light If meter reading is greater ...

Страница 16: ...e knob to ON Place ON OFF switch to ON Check with millivolt meter at generator terminals Millivolt meter should read greater than 100 m v If the reading is OK and the burner does not come on replace the gas valve E Plugged burner orifice 1 Check burner orifice for stoppage and remove F Wall switch or wires 1 Follow corrective action in B 1 defective above check switch and wiring Replace where defe...

Страница 17: ...Line 18 TV 118 42 Middle Right Log 6 TV 106 On Off Switch 19 TV 119 42 Top Left Log 5 TV 105 Piezo Ignitor 20 TV 120 42 Top Right Log 7 TV 107 Pilot Assembly Nat 21 TV 121 Ember Material 8 TV 108 Pilot Assembly LP 22 TV 122 Vermiculite 9 TV 109 Thermopile 23 TV 123 Volcanic Rock 10 TV 110 Pilot Assembly Bracket 24 TV 124 Temp Limit Switch 11 TV 111 Burner Orifice NAT 25 TV 125 Damper Switch 12 TV ...

Страница 18: ... FIRST YEAR AFTER INSTALLA TION GOLDEN BLOUNT MAY DISCHARGE ITS ENTIRE WARRANTY LIABILITY BY REFUNDING THE PRICE OF THE PRODUCT PRODUCTS MADE BY OTHER MANUFACTURERS SOLD WITH THE FIREPLACE OR THEREAFTER ARE NOT COVERED BY THIS LIMITED WARRANTY THE USE OF OTHER UNAUTHORIZED COMPO NENTS WILL MAKE THIS WARRANTY NULL AND VOID THIS LIMITED WARRANTY WILL BE VOID IF THE APPLIANCE IS NOT INSTALLED BY A QU...

Отзывы: