Installing Outside Air Kit
Model LFP
9618
is
supplied with the component parts for outside combustion with the exception of the
4"
duct. It is recommended that the outsid e air system be used whenever possible. Connect 4" Class-1
Flex duct or Metal Vent to duct collar
s
on side of
firebox, run duct to fresh air source and terminate using duct
termination cap
s
. The Outside air can be opened by pulling control knob toward front of
fireplace and
closed by pushing towards rear (Refer to
9.1).
CONTROL
KNOB
DUCT
TERMINATION
LEFT SIDE LFP4218
LEFT AND RIGHT
LFP6018
RAIN CAP
CAULKING
WALL
OUTER
CASING
DUCT
COLLAR
TWO
SUPPLIED
Figure 9.1
Connecting the Gas Line
9
Finishing the Wall
Finish the wall with the material
of your choice. Do not install a
combustible mantle or other
combustible projection above the
opening unless it is a
minimum of 12 inches above top
of
opening. (Figure
9.2
)
CAUTION:
All joints between the
wall and the
surround (Top and
Sides) can only be sealed with non-combustible material. Only non-combustible
material can be applied as facing to the
surround. (Figure
9.2
)
Hearth Extension
A Hearth Extension may be installed. But it is not required for vented gas
STUD
2X4
HEADER
FINISHED
WALL
NON-COMBUSTIBLE
SEAL JOINT
MANTLE
12" MIN
TOP OF
OPENING
Figure
9.2
Consult local building codes
before gas line installation. This gas fireplace is designed
to accept a 1/2" supply line. Have the gas line installed by a qualified service person in
accordance with all building codes. Install gas line to fireplace on the right side
attaching gas line to the gas flex line inside the control box accessed by opening the
control box door.