General

The following pages outline important safety 

information. At Goldacres safety is a high 

priority. These safety and warning instructions 

MUST be followed to ensure the safe 

operation of your Goldacres equipment.
Explanation of key terms used in this 

operator’s manual are:
DANGER - You will be killed or seriously hurt if 

you don’t follow instructions
WARNING - You can be seriously hurt if you 

don’t follow instructions
CAUTION - You can be hurt if you don’t follow 

instructions
NOTE - Is used to notify people of installation, 

operation or maintenance information that is 

important but not hazard related.

The Operator

All operators of this equipment should be 

adequately trained in the safe operation of this 

equipment.  It is important that all operator’s 

have read and fully understand the operators 

manual prior to using this equipment.
All new operators should be trained in an 

area without bystanders or obstructions and 

become familiar with the sprayer prior to 

operation.

Safety Precautions

DANGER

•  Cut hazard. Sharp edges. Contact may 

result in injury. Always keep body, head 

and hands away from sharp edges.

 

WARNINGS

•  Any unauthorised modifications to this 

equipment may affect its function and 

create a serious safety risk.

•  Never attempt to clean parts or nozzles, 

by blowing with mouth.

•  Never attempt to siphon chemicals, or 

substances, by sucking.

•  It is imperative that the vehicle 

manufacturer’s specifications be 

checked and all instructions for use when 

transporting, or towing, be adhered to at 

all times.

•  Water weighs 1kg per litre, however 

conversion factors must be used when 

spraying liquids that are heavier or lighter 

than water. Example: liquid urea has a 

density of 1.28 kg/L and will therefore be 

significantly heavier than water if the tank 

is filled completely. 

•  Ensure equipment is securely fastened, or 

attached, to the vehicle at all times.

CAUTIONS

•  A supply of fresh water should be with the 

equipment at all times.

•  Do not use this machine in ambient 

temperatures exceeding 40 degrees 

Celsius. 

NOTES

•  Always read and understand the 

operator’s manual prior to operation of this 

equipment. 

•  It is the responsibility of the operator to 

ensure that there are no decals missing 

from the equipment and that any damaged 

or missing decals are replaced prior to 

operation. 

•  Goldacres equipment ordered or operated, 

outside the guideline limitations may not 

be warranted by Goldacres for successful 

performance. Operators working outside 

these limitations do so at their own risk, 

unless specific advice has been sought 

from and provided by Goldacres in writing.

•  Inspect the equipment thoroughly for 

damage and wear before operation. 

•  Do not operate the equipment while under 

the influence of any drugs, alcohol or if 

excessively tired.

•  Make sure that the equipment complies 

with all relevant road regulations when 

transporting. 

•  After reading the operator’s manual if there 

is any thing that you do not understand 

please contact your Goldacres dealer or 

Goldacres.

Содержание BETA 110

Страница 1: ...1 UDOR Diaphragm Pumps Operator s Parts Manual GA8700374 REV 1 0 MAR 16 ...

Страница 2: ...6 Warranty 36 Goldacres Warranty Statement 37 Terms and Conditions 38 Revision number 1 0 2 3 2016 Operator s Manual Part Number GA8700374 Contact Goldacres 1 3 Morang Crescent Mitchell Park Vic 3355 P 03 5342 6399 F 03 5342 6308 info goldacres com au Please note All information in this operator s manual is based on the latest product information available at the time of printing The policy of Gol...

Страница 3: ...the pump also needing to supply agitation to the main tank For example a 250 l min pump should realistically achieve a maximum flow of approximately 125 l min to the boom Goldacres Crop Cruisers are fitted with hydraulic drive diaphragm pumps Trailed Sprayers Hydraulically driven pumps are becoming more common as tractors come out with more hydraulic outlets Fitting a hydraulic drive to the pump e...

Страница 4: ...in detail herewith do not use for different liquids in particular it is NOT possible to use UDOR Pumps in the following conditions In the presence of water with high salt content such as seawater for example In workplaces where there is a corrosive or explosive atmosphere In the presence of any liquid that is not compatible with the constructional material of the Pump To pump paint solvents fuel a...

Страница 5: ... exceed the RPM written on the Label of the actual Pump The minimum RPM admitted is maximum RPM x 0 6 The rotation direction of the shaft of UDOR Pumps may be clockwise or anticlockwise Controls on System Unloader Valve A pressure regulator valve must be installed to avoid the pressure exceeding the maximum limit indicated on the Label of the Pump Use of the Pump even for a short period with a pre...

Страница 6: ...tilation conditions Assembly Fit the Pump on a rigid surface keeping the power take off and support feet horizontal to ensure correct drainage in the case of leakage of water or oil The Pump must be secured firmly on a base which must be perfectly aligned with the transmission components In the case of belt transmission make sure the pulleys are aligned and check the tension of the belts Use appro...

Страница 7: ...Remove the head bolts A then remove the Pump head B which may require some light prying 4 DIAPHRAGM REMOVAL Turn crankshaft N to bring piston Q up to the top of its stroke remove the diaphragm bolt L and washer M then remove the diaphragm O If necessary take off one sleeve P and wash well the internal components using diesel fuel The sleeve P must be re mounted in the same position as before 5 INS...

Страница 8: ...40 MOBIL Super M 15W 40 SHELL Rimula R4 15W 40 Helix Super 15W40 TOTAL Rubia 15W 40 Quartz 5000 15W 40 The oil is to be changed by draining it through the dedicated bottom discharge cap and strictly with the Pump stopped The oil level could vary during priming then it will stabilize when the system is pressurized If the oil level gets lower during the first few hours of the pump s operation it cou...

Страница 9: ...ation Excessive pulsation Pulsation dampener pressure too low or too high Adjust pulsation dampener pressure see page 6 Air leak in inlet line Examine hoses and fittings ensure air tight fit and no leaks Insufficient strainer capacity or dirty or plugged strainer Use larger capacity strainer or clean strainer Air not entirely evacuated from Pump cavity Run Pump with an open discharge to totally ev...

Страница 10: ...20 0 05 4 9 KAPPA 15 0 10 0 22 0 11 0 03 2 5 5 5 KAPPA 25 KAPPA 32 0 26 0 57 0 29 0 08 8 18 KAPPA 40 DELTA 40 KAPPA 50 0 49 1 08 0 55 0 15 11 24 KAPPA 33 KAPPA 43 KAPPA 53 0 56 1 23 0 63 0 17 11 24 KAPPA 55 KAPPA 65 0 62 1 37 0 69 0 18 13 29 KAPPA 75 1 04 2 29 1 16 0 31 18 40 KAPPA 100 1 02 2 25 1 14 0 30 20 44 KAPPA 125 1 82 4 01 2 03 0 54 28 62 KAPPA 120 KAPPA 150 1 76 3 88 1 97 0 52 42 93 OMEGA...

Страница 11: ...11 Torque Specification PTO for details on Torque Specification ...

Страница 12: ...IOTA 20 IOTA 25 14 10 25 18 25 18 KAPPA 15 14 10 14 10 14 10 KAPPA 25 KAPPA 32 25 18 40 30 40 30 KAPPA 40 DELTA 40 KAPPA 50 25 18 40 30 40 30 KAPPA 33 KAPPA 43 KAPPA 53 25 18 40 30 10 7 KAPPA 55 KAPPA 65 25 18 40 30 40 30 10 7 KAPPA 75 25 18 40 30 40 30 10 7 KAPPA 100 25 18 40 30 28 20 10 7 KAPPA 125 25 18 40 30 28 20 10 7 KAPPA 120 KAPPA 150 30 22 45 33 28 20 10 7 OMEGA 135 30 22 40 30 OMEGA 140 ...

Страница 13: ...ZETA 260 ZETA 300 34 25 8 6 10 7 RO 320 RO 400 34 25 10 7 30 22 IOTA 20 IOTA 25 25 18 KAPPA 15 10 7 KAPPA 25 KAPPA 32 KAPPA 40 DELTA 40 KAPPA 50 34 25 KAPPA 33 KAPPA 43 KAPPA 53 8 6 KAPPA 55 KAPPA 65 34 25 8 6 KAPPA 75 34 25 8 6 KAPPA 100 34 25 8 6 KAPPA 125 34 25 8 6 KAPPA 120 KAPPA 150 34 25 10 7 OMEGA 135 34 25 10 7 30 22 OMEGA 140 34 25 10 7 30 22 OMEGA 170 34 25 10 7 30 22 BETA 110 34 25 10 7...

Страница 14: ... correct oil use SAE 30W40 motor oil and do not overfill Rotate manually by hand to remove air locks when filling with oil Do not leave water in the pump if the sprayer is to be left in a cold environment The water may freeze and cause damage to pump if pumping is attempted while water is frozen Empty pump of all water run the pump dry for 15 20 seconds and cover pump ie with bag to ensure this si...

Страница 15: ... NOTE Carefully note the position and orientation of all the heads manifolds and valves when disassembling pump Failure to reassemble correctly will result in severe pump damage Remove diaphragms Remove cylinder sleeves Flush inside of pump with diesel Visually inspect inner workings of pump Reassemble with new diaphragms must be correct diaphragms once satisfied with condition of pump Refill with...

Страница 16: ...16 IOTA 20 ...

Страница 17: ...A 20 IOTA 25 GR 3 7 4 0 450 500 550 600 450 500 550 600 15 9 16 8 17 6 19 0 4 9 4 4 4 6 5 0 0 2 0 2 0 2 0 2 0 1 0 1 0 1 0 1 12 6 14 1 15 3 16 9 3 3 3 7 4 0 4 5 0 3 0 3 0 3 0 3 0 2 0 2 0 2 0 2 12 2 13 7 14 9 16 5 3 2 3 6 3 9 4 4 0 3 0 4 0 4 0 5 0 3 0 3 0 3 0 3 11 9 13 4 14 6 16 2 3 1 3 5 3 9 4 3 0 5 0 5 0 6 0 6 0 3 0 4 0 4 0 5 11 7 13 2 14 4 16 0 3 1 3 5 3 8 4 2 0 6 0 7 0 8 0 8 0 5 0 5 0 6 0 6 18 5...

Страница 18: ...18 Kappa 40 Delta 40 ...

Страница 19: ...9 9 7 0 8 0 9 1 0 1 1 0 6 0 6 0 7 0 8 26 3 29 7 33 1 36 4 6 9 7 8 8 7 9 6 1 4 1 6 1 7 1 9 1 0 1 1 1 3 1 4 25 9 29 3 32 7 36 0 6 8 7 7 8 6 9 5 2 0 2 3 2 5 2 8 1 5 1 7 1 9 2 1 25 6 29 0 32 4 35 7 6 8 7 7 8 6 9 4 2 6 3 0 3 3 3 7 1 9 2 2 2 4 2 7 41 6 46 1 50 0 53 5 11 0 12 2 13 2 14 1 0 4 0 5 0 5 0 5 0 3 0 3 0 4 0 4 31 7 36 2 40 1 43 4 8 4 9 6 10 6 11 5 0 9 1 0 1 1 1 2 0 7 0 8 0 8 0 9 31 1 35 6 39 5 4...

Страница 20: ...20 Zeta 70 ...

Страница 21: ...r 0 PSI 10 bar 145 PSI 15 bar 217 PSI 20 bar 290 PSI 5 bar 72 PSI l min l min l min l min l min GPM GPM GPM GPM GPM HP HP HP HP HP kW kW kW kW kW Kg ZETA 70 8 7 51 5 57 6 63 5 70 5 400 450 500 550 13 6 15 2 16 8 18 6 0 5 0 6 0 6 0 7 0 4 0 4 0 5 0 5 49 1 55 1 61 2 66 6 13 0 14 6 16 2 17 6 1 0 1 1 1 2 1 3 0 7 0 8 0 9 1 0 48 8 54 6 60 8 66 2 12 9 14 4 16 1 17 5 1 4 1 6 1 7 1 9 1 0 1 1 1 6 1 4 48 4 54...

Страница 22: ...22 Zeta 85 ...

Страница 23: ... 20 4 22 4 0 6 0 7 0 8 0 8 0 5 0 5 0 6 0 6 58 6 65 9 73 2 80 4 15 5 17 4 19 3 21 2 1 2 1 3 1 5 1 6 0 9 1 0 1 1 1 2 58 2 65 5 72 7 79 9 15 4 17 3 19 2 21 1 1 7 1 9 2 1 2 3 1 2 1 4 1 5 1 7 57 5 64 9 72 2 79 4 15 2 17 1 19 1 21 0 2 3 2 6 2 9 3 2 1 7 1 9 2 1 2 3 57 3 64 6 71 8 79 0 15 1 17 1 19 0 20 9 3 0 3 4 3 8 4 2 2 2 2 5 2 8 3 1 12 33 0 36 5 40 2 44 0 400 450 500 550 8 7 9 6 10 6 11 6 0 3 0 4 0 4 ...

Страница 24: ...24 Zeta 100 ...

Страница 25: ...GPM GPM GPM HP HP HP HP HP kW kW kW kW kW Kg ZETA 100 13 RIDUTTORI 15 Vedi pag 42 GEAR REDUCTIONS 15 See page 42 1C VA TS 1C alberi P di F disponibili available P T O shaft Per le dimensioni degli Alberi P di F vedi pag 35 For P T O Shaft dimensions see page 35 72 8 81 6 90 4 98 0 400 450 500 550 19 2 21 6 23 9 25 9 0 7 0 8 0 9 1 0 0 5 0 6 0 7 0 7 69 2 77 6 86 0 92 7 18 3 20 5 22 7 24 5 1 4 1 6 1 ...

Страница 26: ...26 Zeta 140 ...

Страница 27: ...0 ZETA 140 18 18 86 9 96 6 106 3 116 0 101 7 119 8 123 9 135 0 23 0 25 5 28 1 30 6 26 6 31 4 32 5 35 4 0 9 1 0 1 1 1 2 1 0 1 2 1 2 1 3 0 6 0 7 0 8 0 9 0 7 0 9 0 9 1 0 83 7 93 4 103 1 112 8 97 6 108 7 119 8 130 9 22 1 24 7 27 2 29 8 25 8 28 7 31 7 34 6 1 1 1 2 1 3 1 4 1 3 1 4 1 5 1 7 0 8 0 9 1 0 1 1 0 9 1 0 1 1 1 2 82 8 92 5 102 2 111 9 97 2 108 3 119 4 130 5 21 9 24 4 27 0 29 6 25 7 28 6 31 5 34 5...

Страница 28: ...28 Zeta 170 ...

Страница 29: ...il bl P il bl PT P PTO h ft T TO h ft PSI 550 RPM PSI 550 RPM PSI 550 RPM 1C MI TS 2C 13 13 24 26 125 9 140 6 155 3 170 0 145 8 163 2 180 6 198 0 33 3 37 1 41 0 44 9 38 5 43 1 47 7 52 3 1 3 1 4 1 6 1 7 1 5 1 6 1 8 2 0 0 9 1 0 1 1 1 2 1 1 1 2 1 3 1 5 121 0 135 7 150 4 165 1 140 9 158 3 175 7 193 1 32 0 35 9 39 7 43 6 37 2 41 8 46 4 51 0 1 6 1 7 1 9 2 1 1 8 2 0 2 3 2 5 1 1 1 3 1 4 1 6 1 3 1 5 1 7 1 ...

Страница 30: ...30 Zeta 260 ...

Страница 31: ...0 2 50 4 56 2 61 9 67 6 56 9 63 9 70 9 77 9 1 7 1 9 2 1 2 3 1 9 2 1 2 3 2 6 2 2 2 4 2 7 3 0 1 2 1 4 1 5 1 7 1 4 1 6 1 7 1 9 1 6 1 8 2 0 2 2 164 1 183 6 203 1 222 6 185 5 207 2 228 9 250 6 213 3 239 3 265 3 291 3 43 4 48 5 53 7 58 8 49 0 54 7 60 5 66 2 56 4 63 2 70 1 77 0 2 1 2 4 2 6 2 9 2 4 2 7 2 9 3 2 2 7 3 1 3 4 3 7 1 5 1 7 1 9 2 1 1 7 2 0 2 2 2 4 2 0 2 3 2 5 2 7 162 8 182 3 201 6 221 3 184 2 20...

Страница 32: ...32 Zeta 300 ...

Страница 33: ...aphragm kit KIT ZETA260D Zeta 300 Diaphragm kit KIT ZETA300D Complete Kits Includes side diaphragms air diaphragm where applicable valves o rings and oil seals Suits Pump Type Part No IOTA20 Complete kit GA5023875 SK Kappa 40 Complete kit KIT KAPPA40 C Zeta 85 Complete kit KIT ZETA85C Zeta100 Complete kit KIT ZETA100C RO121 130 Complete kit KIT ZETA140C Zeta 140 Complete kit KIT ZETA140C RO160 Com...

Страница 34: ...plete Kit 4 x 090359 1 x 090314 8 x 600677 8 x GA5020060 1 x 000749 1 x 110158 KIT ZETA170 D Zeta 170 Diaphragm Kit 4 x 090359 1 x 090314 KIT ZETA260 C Zeta 260 complete Kit 6 x 090359 12 x 600677 12 x GA5020060 1 x 000749 1 x 110158 1 x 000741 KIT ZETA260 D Zeta 260 Diaphragm kits 6 x 090359 KIT ZETA300 C Zeta 300 Complete Kit 6 x 090359 12 x 600677 12 x GA5020060 1 x 000749 1 x 110158 1 x 000741...

Страница 35: ...he vehicle manufacturer s specifications be checked and all instructions for use when transporting or towing be adhered to at all times Water weighs 1kg per litre however conversion factors must be used when spraying liquids that are heavier or lighter than water Example liquid urea has a density of 1 28 kg L and will therefore be significantly heavier than water if the tank is filled completely E...

Страница 36: ...ischarge which may be hazardous When the repair is complete ensure that all fittings and lines are secured before re applying pressure Warranty How to make a warranty claim In the event of a fault or breakdown with your product that you believe to be a warranty issue the following steps must be taken 1 Ensure that you have read the Operator s Manual and gone through the troubleshooting procedure 2...

Страница 37: ...anship or materials used under normal use and service conditions The Warranty is not transferable The owner is responsible for the performance of regular maintenance and service as specified in the owner s operators manual applicable to the product Failure to follow regular maintenance as advised may invalidate the warranty The owner must provide the Goldacres Dealer with prompt written notice of ...

Страница 38: ...od any defects by repairing the same or at Goldacres option by replacement within a period not exceeding either 1000 hours or twelve calendar months whichever comes first after the Goods have been dispatched provided that i the defects have arisen solely from faulty materials or workmanship ii the Goods have not received maltreatment inattention or interference iii accessories of any kind used by ...

Страница 39: ...very of the Goods and has not agreed to postpone the time for attachment of the security interest as defined in the PPSA granted to Goldacres under these terms and conditions 4 The Purchaser will execute documents and do such further acts as may be required by Goldacres to register the security interest granted to Goldacres under these terms and conditions under the PPSA 5 Until ownership of the G...

Страница 40: ...40 1 3 Morang Crescent Mitchell Park Vic 3355 P 03 5342 6399 F 03 5342 6308 info goldacres com au goldacres com au ...

Отзывы: