Pralinator 2181EL, 2181ER, 2181DEL, 2181DER
5
ELECTRICAL REQUIREMENTS
The following power supply must be provided (reference unit Data Plate for Wattage requirement):
2181EL, 2181ER, 2181DEL, 2181DER:
120v/208v or 120v/240v, 60 Hz.
This unit is designed to operate on single phase, 20 AMP, 4 wire supply, 120/208 or 120/240 V~
(2 Hot, 1 Neutral, 1 Ground). All electrical components in this machine are 120 V (motors, heat
elements, lights, etc.) and therefore require “Hot to Neutral” connection (
NOT
“Hot to Hot”). A wall
receptacle is supplied with the machine. This receptacle will accept the attachment plug on the
machine and must be used.
DANGER
Machine must be properly grounded to prevent electrical shock to personnel.
Failure to do so could result in serious injury, or death.
Make sure all machine switches are in the OFF position before plugging the
equipment into the receptacle. Keep cord and plug off the ground and away
from moisture. Always unplug the equipment before cleaning or servicing.
DO NOT immerse any part of this equipment in water.
DO NOT use a water jet or excessive water when cleaning.
008_012221
A certified electrician must furnish sufficient power for proper machine operation and install any supplied
receptacle (reference unit Data Plate for model specific Volts AC, Hertz, and Wattage requirements). We
recommend this equipment be on a dedicated and protected circuit. Failure to wire properly will void the
warranty and may result in damage t
o the machine. It is Gold Medal Products Co.’s recommendation that
this machine be plugged directly into a wall outlet. The use of extension cords is not recommended due to
safety concerns, and may cause sacrificed and/or reduced performance. Make sure cord is located to
prevent a trip hazard or unit upset.
Receptacle Installation
A certified electrician must follow the IMPORTANT instructions below for installation of the
L14-20 Receptacle (Gold Medal Item No. 41254) provided with Model 2181 Series units.
If the receptacle is wired incorrectly, the heat elements/kettle and other electrical components could be at
208 or 240 V potential instead of the needed 120 V, resulting in excessive temperatures in the heat
elements (i.e.: kettle) and possible fire, and/or damage to electrical components.
L14-20 Back View
Green Terminal
Connect to Green
(Ground) Wire
Brass Terminal
Connect to Red
(Hot) Wire
G
Y
Brass Terminal
Connect to Black
(Hot) Wire
Silver Terminal
Connect to White
(Neutral) Wire
X
W
L14-20
Front View