get ALL METAL mode. LCD displays ALL METAL at the left lower part 

of the screen. 

Press  GROUND  TRAC  several  times  to  allow  the  unit  to  stabilize 

when first going into ALL METAL mode. 

    Lower  the  searchcoil  to  about  one  inch  (2.5cm) above  the  ground. 

Slowly  sweep  the  searchcoil  above  the  ground.  When  the  unit 

passes  over metal  object,  LCD will  display  the  depth  of  the  object. 

Also the unit emits a tone. When the unit approaches the target , it 

emits a higher tone. 

When  searching  in  the  ALL  METAL  mode,  it  is  important  that  the 

detector  be  ground  balanced  to  offset  the  effects  of  any  minerals 

present  in  the  soil  or  to  balance  the  effects  of  saltwater  when  you 

search near the ocean. 

 

GROUND  BALANCE—used  to  offset  the  effects  of  any  minerals 

present in the soil or to balance the effects of saltwater. 

1.  Begin with the GROUND BALANCE button adjusted to PRE SET 

and  lift  the  searchcoil  about  waist  high  in  the  air.  Press  GND 

TRAC  several  times  to  let  the  unit  stabilize  before  starting  an 

effective detection. 

2.  Lower the searchcoil to about one inch (2.5cm) above the ground. 

If a tone is not being emitted, the PRE SET position is the proper 

ground balance for that area. If a tone is being emitted, readjust 

the GND BAL. 

3.  Lift the searchcoil in the air, turn the GND BAL counterclockwise 

slightly.  Push  GND TRAC  several  times. Then  repeat  step  2.  If 

the unit still emits tone, repeat the procedure until the unit does 

not emit tone.   

Note:   

1.  Always  be  careful  that  there’s  no  metal  on  top  of  or  under  the 

ground where you proceed ground balancing. 

Содержание GC-1019

Страница 1: ...Gold Century GC 1019 Metal Detector Advanced Professional Digital LCD Display Advanced Metal Detector OWNER S MANUAL And Warranty...

Страница 2: ...C and NOTCH to reject any trash item Motion is now required to make a detection Items will be tuned out if coil is not in motion Note Do not attempt to test unit by placing a coin or metal objects ont...

Страница 3: ...ctor s control housing Caution The search coil s plug fits into the jack only one way Do not force the plug or you could damage it To disconnect the cable pull out the plug Do not pull on the cable 7...

Страница 4: ...eries promptly and properly Never bury or burn them Caution If you don t plan to use the unit for a week or more time remove the batteries Batteries can leak chemicals that can destroy electronic part...

Страница 5: ...o not listen at extremely high volume levels Extended high volume listening can lead to permanent hearing loss Do not wear headphones while operating your detector near high traffic areas Pay attentio...

Страница 6: ...tain optimum ground balance at all times 6 Used to increase or decrease the sensitivity and the range of discrimination Please refer to the detailed instructions for above touchpads in OPERATION DISPL...

Страница 7: ...ithin the SILVER range 5 NICKEL indicates that the target is probably 5 or a nickel Some fine gold ring might register in this range PULL TAB indicates that the target is probably a pull tab of an alu...

Страница 8: ...ETECTOR Slide the power switch to ON The unit displays all symbols on the LCD screen The detector sounds low medium high tones respectively After about 2 seconds the detector enters stand by state At...

Страница 9: ...f DISC NOTCH AUTO NOTCH press ADJ to adjust the sensitivity LCD displays SENS Press to increase the sensitivity Press to decrease it Note In order to detect the target deeply buried you can adjust the...

Страница 10: ...ar the ocean GROUND BALANCE used to offset the effects of any minerals present in the soil or to balance the effects of saltwater 1 Begin with the GROUND BALANCE button adjusted to PRE SET and lift th...

Страница 11: ...be pushed afterwards TESTING AND USING THE DETECTOR To learn how the detector reacts to different metals you should test it before you use it the first time You can test the detector indoors and outdo...

Страница 12: ...t it more easily if you hold it so a flat side is parallel with the flat side of the searchcoil A sweep with the side of coin over search coil might cause false indication and unstable display of arro...

Страница 13: ...ith the ground If the detector detects the item it sounds a tone an arrow and the depth appear on the display below the target icon If the detector does not detect the item make sure that the operatin...

Страница 14: ...ed target continue sweeping the search coil over the target in a narrowing side to side motion 2 Make a visual note of exact spot on the ground where the detector beeps 3 Stop the search coil directly...

Страница 15: ...ons will help you care for your metal detector so you can enjoy it for years Handle the detector gently and carefully Dropping it can damage circuit boards and cases and can cause the detector to work...

Страница 16: ...orthwhile YOUR LCD READOUT IS NOT LOCKING IN OR ID ING WHILE PASSING OVER A TARGET THERE IS MORE THAN ONE TONE BEING EMITTED BY THE DETECTOR OVER THE SAME TARGET This will usually occur when there s m...

Страница 17: ...de your original purchase receipt This warranty is not valid for defects caused by accidents misuse improper care alteration or abuse nor is it valid if any service or repair is performed by non autho...

Отзывы: